Delta ISPSoft contains an out-of-bounds read (CWE-125) that can crash the application and potentially leak limited memory contents when a user opens a specially crafted project file. Exploitation is client-side and requires user interaction (opening the file on an engineering workstation), not remote access to a listening service, so the practical risk is moderate. No public exploit code has been identified at time of analysis.
Out-of-bounds read in Delta ISPSoft can disclose limited sensitive memory contents and cause a high availability impact when a user opens a specially crafted project or data file. The vulnerability affects installations of the Delta ISPSoft engineering software (CPE cpe:2.3:a:deltaww:ispsoft:*:*:*:*:*:*:*:* indicates no version limitation in the supplied data) and is a client-side file-parsing issue requiring user interaction, not an unattended network service flaw. No public exploit identified at time of analysis; the independent assessment rates it as a moderate-priority, client-side exposure rather than a mass-exploitable server vulnerability.
Path traversal in Delta Electronics DIAEnergie before 1.11.00.022 allows unauthenticated remote attackers to manipulate file paths on the host, with the CVSS vector indicating high integrity and availability impact but no confidentiality impact, which is consistent with arbitrary file writing, overwriting, or deletion rather than file disclosure. Exploitation is rated CVSS 9.1 (AV:N/AC:L/PR:N/UI:N) and requires only network reachability to the DIAEnergie web application - no credentials, user interaction, or non-default configuration are prerequisites. No public exploit code has been identified at time of analysis and there is no CISA KEV listing, so current risk is driven by intrinsic severity and exposure rather than observed exploitation in the wild. The practical threat hinges on exposure: DIAEnergie is a niche industrial energy-management platform typically deployed on segmented OT/enterprise networks, so internet-facing or broadly reachable management interfaces carry the highest risk.
SQL injection in Delta Electronics DIAEnergie before version 1.11.00.022 allows an attacker holding a valid low-privileged account to read from and write to the platform's backend database, putting the confidentiality, integrity, and availability of its operational data at risk. The flaw is network reachable (AV:N), requires only a low-privileged session (PR:L), and needs no user interaction; it is not confirmed as actively exploited (no CISA KEV listing) and no public exploit code has been identified at time of analysis. Delta released the fix in advisory PCSA-2026-00014 alongside a batch of related DIAEnergie flaws, including an authentication bypass (CVE-2026-78308) that could supply the very credentials this SQL injection depends on.
SQL injection in Delta Electronics DIAEnergie versions before 1.11.00.022 lets a remote attacker with any valid low-privileged account (CVSS PR:L) execute arbitrary SQL against the underlying database, resulting in full loss of confidentiality, integrity, and availability (CVE-2026-78309, CWE-89, base score 8.8). The flaw is network-reachable with low attack complexity and no user interaction, so it can be triggered directly over the DIAEnergie web interface, though valid credentials are required and the specific vulnerable parameter or endpoint has not been disclosed in the available data. No public exploit code has been identified and the issue is not listed as confirmed actively exploited (CISA KEV), so the immediate risk is highest for internet- or IT-network-exposed deployments where low-privileged accounts are broadly issued. The advisory from Delta covers this CVE alongside five siblings (CVE-2026-78308 through CVE-2026-78313).
Improper authentication in Delta Electronics DIAEnergie before 1.11.00.022 allows authentication bypass, enabling remote attackers to reach protected functionality without valid credentials. The flaw carries a CVSS 3.1 base score of 9.8 (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H), meaning exploitation requires no authentication, no user interaction, and no non-default configuration - only network reachability to the DIAEnergie service. There is no public exploit identified at time of analysis and no confirmed active exploitation (CISA KEV); the practical exposure is limited chiefly by the product's footprint, as DIAEnergie is a niche ICS energy-management platform typically deployed on operational or enterprise networks rather than the public internet.
SQL injection in Delta DIAEnergie versions up to and including 1.11.00.002 enables low-privileged authenticated remote attackers to achieve full remote code execution on the host system. The flaw (CWE-89) is network-exploitable with low complexity, affecting an industrial energy management platform used in OT environments where RCE carries significant operational risk. No public exploit code or CISA KEV listing has been identified at time of analysis, though the vendor has published a security advisory.
SQL injection in Delta DIAEnergie versions up to and including v1.11.00.002 enables authenticated network-based attackers to achieve remote code execution on the underlying server. Carrying a CVSS base score of 8.8 with low-privilege, low-complexity network access required, this flaw poses serious risk to operational technology environments that depend on this energy management platform for monitoring and control. No public exploit code or CISA KEV listing has been identified at time of analysis, though Delta Electronics has self-disclosed the issue via vendor advisory PCSA-2026-00015.
SQL Injection in Delta Electronics DIAEnergie versions up to and including 1.11.00.002 enables a low-privileged remote attacker to achieve full remote code execution on the underlying server. Confirmed by vendor advisory Delta-PCSA-2026-00015 and ENISA EUVD-2026-64760, the flaw (CWE-89) stems from unsanitized user input passed directly to backend SQL queries, with the database engine serving as the execution bridge to the OS. No public exploit or CISA KEV listing has been identified at time of analysis, but the network-accessible RCE impact in an industrial energy management context elevates this to a high-priority remediation target.
SQL injection in Delta DIAEnergie versions up to and including v1.11.00.002 enables authenticated network-accessible attackers to escalate from data manipulation to remote code execution on the underlying host. Confirmed by vendor advisory Delta PCSA-2026-00015 and EUVD-2026-64759, the vulnerability (CWE-89) carries a CVSS 3.1 score of 8.8, reflecting low attack complexity and full CIA impact. No public exploit or CISA KEV listing has been identified at time of analysis, but the RCE pathway in an energy management system warrants priority remediation.
Denial-of-service exposure in the Delta Electronics DVP80ES3 programmable logic controller (part of the DVP-ES3 series) stems from an improperly implemented standard security check (CWE-358) that a remote, unauthenticated attacker can abuse over the network to force a loss of availability. The CVSS 4.0 base score is 8.7 (High), driven entirely by high availability impact with no confidentiality or integrity impact in the scored vector. There is no public exploit identified at time of analysis and it is not listed in CISA KEV; note that the vendor's tags label this 'Information Disclosure,' which conflicts with the availability-only CVSS vector and should be verified against the Delta advisory.
Denial of service in Delta Electronics DVP80ES3 programmable logic controllers arises from a failure to enforce message integrity on a communication channel (CWE-924), allowing remote, unauthenticated attackers to inject or tamper with protocol messages and disrupt device availability. Per the vendor CVSS vector (AV:N/AC:L/PR:N/UI:N/C:N/I:N/A:H), the confirmed impact is loss of availability of this industrial controller with no privileges or user interaction required. There is no public exploit identified at time of analysis and it is not listed in CISA KEV, though the network-reachable, no-auth profile of an ICS device makes it operationally significant.
Denial of service in Delta Electronics DVP80ES3 programmable logic controllers arises from an improper resource shutdown or release flaw (CWE-404) that lets remote unauthenticated attackers exhaust or corrupt device resources. Per the CVSS vector the impact is limited to availability (A:H) with no confidentiality or integrity loss, meaning a successful attacker can crash or hang the PLC and disrupt the controlled industrial process. No public exploit identified at time of analysis; the issue is documented in Delta advisory Delta-PCSA-2026-00009, which bundles it with CVE-2026-12576 and CVE-2026-12577.
Denial-of-service in the Delta Electronics DVP80ES300T programmable logic controller allows remote unauthenticated attackers to crash the device by triggering an improper array-index validation flaw (CWE-129). Per the CVSS vector the impact is limited to availability (A:H) with no confidentiality or integrity loss, so a successful attack halts PLC operation rather than exposing data. There is no public exploit identified at time of analysis and it is not listed in CISA KEV; EPSS was not provided.
Authentication bypass in the Delta Electronics AS228T programmable logic controller allows remote attackers to circumvent authentication controls and gain unauthorized access to controller functions over the network, threatening the integrity and availability of the industrial process it governs. The CVSS 3.1 base score is 7.4 (High), driven by high integrity and availability impact (I:H/A:H) with no confidentiality loss, but tempered by high attack complexity (AC:H). At the time of analysis there is no public exploit identified and the flaw is not listed in CISA KEV; no EPSS value was supplied.
Arbitrary code execution in Delta Electronics DTMSoft arises from unsafe deserialization of untrusted data during project file parsing (CWE-502), allowing an attacker who supplies a malicious DTMSoft project file to run code in the context of the user who opens it. The flaw is local and requires victim interaction (opening the crafted file) rather than remote network exploitation, and impacts confidentiality, integrity, and availability fully. There is no public exploit identified at time of analysis and the issue is not listed in CISA KEV; no EPSS score was supplied.
Unauthenticated Modbus TCP exposure on the Delta Electronics DVP12SE programmable logic controller lets any network-reachable attacker invoke security-sensitive PLC functions - reading and writing process registers, coils, and configuration - with no credentials or access control. The flaw (CWE-306, Missing Authentication for a Critical Function) carries a CVSS 4.0 base of 9.3 and is documented in Delta advisory PCSA-2026-00011 alongside CVE-2026-12818. There is no public exploit identified at time of analysis and no CISA KEV listing, but the Modbus protocol is trivially scriptable and well understood, lowering the practical exploitation bar.
Resource exhaustion in Delta Electronics DVP12SE programmable logic controllers lets remote attackers crash or hang the device by overwhelming its Modbus TCP service, which lacks connection/resource throttling (CWE-770). Any host able to reach the PLC's Modbus TCP port can degrade or deny control of the affected industrial process. There is no public exploit identified at time of analysis and the issue is not listed in CISA KEV, but the unauthenticated network attack surface makes it a meaningful availability risk in OT environments.
Unchecked directory name buffer in Delta Electronics AS320T enables remote code execution without authentication. The CVSS vector (AV:N/AC:L/PR:N/UI:N) confirms this is a remotely exploitable stack buffer overflow (CWE-121) requiring no user interaction or credentials. Delta Electronics disclosed this vulnerability in security advisory PCSA-2026-00006, affecting an industrial automation product. No EPSS score or KEV status available at time of analysis, but the trivial exploitation requirements (network accessible, no authentication, low complexity) present immediate risk to exposed AS320T devices.
Remote unauthenticated attackers can trigger denial of service in Delta Electronics AS320T industrial automation devices by invoking an undocumented subfunction. The vulnerability allows network-accessible exploitation without credentials against default configurations, potentially disrupting critical industrial control operations. Delta Electronics confirmed the flaw in PCSA-2026-00006, grouped with three other CVEs affecting the same product line.
Remote code execution in Delta Electronics AS320T allows unauthenticated network attackers to exploit an unchecked buffer overflow in filename processing to execute arbitrary code with high impact to confidentiality, integrity, and availability. The CVSS 9.8 critical score reflects network-accessible attack surface with no authentication or user interaction required. No EPSS or KEV data available at time of analysis, but vendor advisory confirms multiple related vulnerabilities affecting the same product line.
Remote code execution in Delta Electronics AS320T industrial automation server allows unauthenticated network attackers to trigger memory corruption via malformed GET/PUT requests to the web service. The incorrect buffer size calculation (CWE-131) enables stack-based overflow attacks against network-exposed management interfaces. With CVSS 9.8 (AV:N/AC:L/PR:N/UI:N) indicating trivial exploitation conditions and CRITICAL severity, this vulnerability represents an immediate risk to industrial control systems deploying this Delta OT product, though no public exploit or active exploitation confirmed at time of analysis.
Stack-based buffer overflow in Delta Electronics ASDA-Soft allows local attackers with no privileges to execute arbitrary code by tricking users into opening a malicious file. The vulnerability achieves complete system compromise (confidentiality, integrity, availability all rated High in CVSS) through user interaction with crafted input. No public exploit identified at time of analysis, though the low attack complexity and lack of required privileges increase realistic exploitation risk once details emerge.
Delta Electronics COMMGR2 has Buffer Over-read DoS vulnerability. [CVSS 7.5 HIGH]
Stack-based buffer overflow in Delta Electronics COMMGR2 communication management software. ICS vulnerability enabling remote code execution on industrial communication gateways.
Arbitrary code execution in Delta Electronics CNCSoft-G2 occurs when the application fails to properly validate user-supplied files, allowing an attacker to execute malicious code by tricking a user into opening a crafted file. This local vulnerability affects industrial environments running CNCSoft-G2 and requires user interaction to exploit. No patch is currently available.
ASDA-Soft Stack-based Buffer Overflow Vulnerability [CVSS 7.8 HIGH]
Delta Electronics DIAView has Command Injection vulnerability. [CVSS 7.8 HIGH]
An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateHDMWYC' message, which is split into 4 fields using the '~' character as the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Improper access control in Delta Electronics DIAEnergie before 1.11.00.022 allows a low-privileged authenticated user to read sensitive data that should be restricted to higher-privilege roles, with network-reachable, low-complexity exploitation that requires no user interaction. The CVSS 3.1 vector (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N, 6.5 Medium) shows the impact is confined to confidentiality - no integrity or availability effect - and the PR:L component means an attacker must already hold at least a valid low-privilege account on the web application rather than being a fully anonymous internet scanner. No public exploit code was identified at time of analysis and the vulnerability is not confirmed as actively exploited (not listed in CISA KEV), so risk is highest for environments where DIAEnergie is network-exposed and accounts are broadly provisioned.
An authorization bypass through a user-controlled key (CWE-639) exists in Delta Electronics DIAEnergie versions before 1.11.00.022, allowing a low-privilege authenticated user to reference objects or records belonging to other users and read data they are not authorized to access. The flaw is network-reachable (AV:N) and requires no victim interaction (UI:N), but exploitation is gated behind a valid low-privilege session (PR:L), so realistic abuse is limited to malicious insiders, legitimate users exceeding their privileges, or attackers who have already obtained credentials; impact is bounded to confidentiality (C:L) with no integrity or availability effect, giving a CVSS 3.1 base score of 4.3. No public exploit code has been identified at time of analysis and the issue is not confirmed actively exploited (CISA KEV), making this a genuine but low-priority weakness rather than a high-severity emergency.
Delta Electronics DIAView has a missing authentication vulnerability that allows remote attackers to access critical functionality without credentials, potentially compromising SCADA monitoring.
Delta Electronics DIAView uses hard-coded cryptographic keys, allowing attackers to forge authentication tokens, decrypt sensitive data, or bypass security controls entirely.
An out-of-bounds memory write in the firmware of the Delta DVP-12SE11T programmable logic controller allows remote attackers to corrupt memory on a network-reachable device, with the supplied CVSS 3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, base 9.8) indicating no authentication or user interaction is required and full loss of confidentiality, integrity, and availability. The flaw is classified as CWE-787 (out-of-bounds write) and is reported against the DVP-12SE11T firmware with no version constraint in the CPE record, meaning all observed firmware builds of that model should be treated as affected until the vendor advisory (Delta PCSA-2025-00022) narrows the range. No public exploit code has been identified at time of analysis and the issue is not listed in CISA KEV; realistic exploitation depends on an attacker first reaching the controller on an OT/plant network segment, since the exact triggering protocol, port, or message type is not disclosed in the available data.
Denial of service in Delta Electronics DVP-12SE11T PLC firmware lets an unauthenticated, remote attacker crash or otherwise render the device unavailable (CVSS 3.1 base 7.5, AV:N/AC:L/PR:N/UI:N with availability-only impact). The vulnerability stems from improper input validation (CWE-20) in the device's exposed network service, and the CPE entry cpe:2.3:o:deltaww:dvp-12se11t_firmware:* indicates all observed firmware versions are affected. Risk is moderate rather than critical: EPSS is 0.32% (23rd percentile), there is no CISA KEV listing and no public exploit identified at time of analysis, and the practical barrier is network reachability - the device is normally deployed inside segmented or air-gapped OT networks, where no authentication or user interaction is required once the attacker can reach the service.
Authentication bypass in Delta DVP-12SE11T PLC firmware allows unauthenticated remote attackers to fully compromise the device via partial password disclosure. The vulnerability is network-reachable, requires no credentials or user interaction, and can lead to complete loss of confidentiality, integrity, and availability. No public exploit code or active exploitation has been identified at time of analysis.
Authentication bypass in Delta DVP-12SE11T PLCs allows remote, unauthenticated attackers to fully compromise the controller’s confidentiality, integrity, and availability (CVSS 9.8). The flaw (CWE-288) leverages an alternate authentication path in the firmware, requiring network access to the device's engineering or communication interface and no user interaction. No public exploit identified at time of analysis; exploitation is primarily limited by OT network segmentation and firewalling.
An out-of-bounds write in Delta Electronics DIAScreen before 1.6.1 lets attackers execute code in the context of the current process when a victim opens a specially crafted project file. The flaw is a file-parsing validation failure (CWE-787) that is strictly client-side: exploitation is local (AV:L) and requires the operator to actively open a malicious file, so there is no remote or unattended attack path. No public exploit code has been identified at time of analysis and EPSS is negligible (0.02%, 3rd percentile), making real-world risk low despite the code-execution potential.
An out-of-bounds write in the file-parsing routine of Delta Electronics DIAScreen (all versions prior to 1.6.1) allows code execution in the context of the current DIAScreen process when a user opens an attacker-crafted project file. The CVSS v4.0 vector is local (AV:L) with PR:N - unauthenticated - but requires active user interaction (UI:A), so the attacker must first deliver a malicious file to an engineering workstation and convince an operator to open it; there is no remote or network-triggered path. No public exploit code has been identified at time of analysis (no CISA KEV listing), and the EPSS score is only 0.02% (3rd percentile), which aligns with our independent assessment that this is a moderate, not high-priority, issue for most environments, though the high availability impact (memory corruption/crash) makes even failed exploitation disruptive on production engineering hosts.
An out-of-bounds write in Delta Electronics DIAScreen's file-parsing routine (all versions from 0 through 1.6.1) allows an attacker to execute code in the context of the current user's process when an engineer or operator opens a crafted project/configuration file. The flaw is exploitable without authentication (CVSS 4.0 vector PR:N) but is strictly local and requires the victim to be socially engineered into opening the malicious file (UI:A), so there is no drive-by, network-reachable, or self-propagating path, and impact stays bounded to the victim's own privileges (S:U, SC:N/SI:N/SA:N). Risk signals point to low real-world urgency: EPSS is only 0.02% (3rd percentile), there is no CISA KEV entry, and no public exploit code has been identified at time of analysis. Delta has released a vendor patch in DIAScreen 1.6.1.
An out-of-bounds write in the file-parsing routines of Delta Electronics DIAScreen (versions prior to 1.6.1) allows a crafted project file to corrupt memory and execute code in the context of the DIAScreen process when a user opens it. Exploitation is local and user-interaction driven: the attacker must deliver a malicious file and induce the victim to open it, so social engineering, not network reachability, is the limiting factor - no pre-existing credentials in the application are needed (PR:N in the assessed vector), but the attack hinges on a user opening the file (UI:A, UI:R in the CVSS 3.1 assessment). Delta has published a fixed build (1.6.1), EPSS is 0.02% (3rd percentile), and no public exploit code has been identified at time of analysis.
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. Rated high severity (CVSS 7.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
DIAEnergie - Reflected Cross-site Scripting. Rated medium severity (CVSS 5.9), this vulnerability is remotely exploitable. No vendor patch available.
DIAEnergie - Reflected Cross-site Scripting. Rated medium severity (CVSS 5.9), this vulnerability is remotely exploitable. No vendor patch available.
DIAEnergie - Reflected Cross-site Scripting. Rated medium severity (CVSS 5.9), this vulnerability is remotely exploitable. No vendor patch available.
DIAEnergie - Stored Cross-site Scripting. Rated high severity (CVSS 7.0), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Local code execution vulnerability in Delta Electronics CNCSoft-G2 resulting from insufficient file validation when processing user-supplied files. An authenticated local attacker can craft a malicious file that, when opened by a user, executes arbitrary code with the privileges of the affected application. This vulnerability has a CVSS score of 7.3 (High) and requires local access and user interaction, making it a significant risk for organizations deploying CNCSoft-G2 in manufacturing or industrial control environments.
Local code execution vulnerability in Delta Electronics CNCSoft caused by insufficient validation of user-supplied files. When a user opens a malicious file, an attacker can execute arbitrary code with the privileges of the current process. While no publicly disclosed POC or active exploitation in the wild has been confirmed, the high CVSS score (7.3) and the file-opening attack vector present moderate risk to users of affected CNCSoft versions.
Buffer overflow vulnerability (CWE-787) in Delta Electronics CNCSoft that allows local authenticated users to execute arbitrary code by opening a specially crafted malicious file. The vulnerability requires user interaction (file opening) but results in complete compromise of the affected process with high impact to confidentiality, integrity, and availability. No KEV status, EPSS score, or confirmed active exploitation data is available in the provided intelligence.
Local arbitrary code execution vulnerability in Delta Electronics CNCSoft caused by insufficient validation of user-supplied files. An attacker with local access can craft a malicious file that, when opened by a user, executes arbitrary code with the privileges of the CNCSoft process. With a CVSS score of 7.3 and CWE-787 (Out-of-bounds Write) classification, this represents a significant local privilege escalation risk, though exploitation requires user interaction and local access.
Local privilege escalation vulnerability in Delta Electronics CNCSoft caused by insufficient validation of user-supplied files. When a user opens a malicious file, an attacker can execute arbitrary code with the privileges of the current process. While the CVSS score of 7.3 is moderate-to-high, the attack requires local access and user interaction, limiting immediate widespread impact; however, the high integrity and confidentiality impact (CWE-787: Out-of-bounds Write) warrants prompt patching.
Delta Electronics ISPSoft version 3.20 is vulnerable to an Out-Of-Bounds Write vulnerability that could allow an attacker to execute arbitrary code when parsing ISP file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics ISPSoft version 3.20 is vulnerable to an Out-Of-Bounds Write vulnerability that could allow an attacker to execute arbitrary code when parsing ISP file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics ISPSoft version 3.20 is vulnerable to a Stack-Based buffer overflow vulnerability that could allow an attacker to execute arbitrary code when parsing DVP file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics ISPSoft version 3.20 is vulnerable to an Out-Of-Bounds Write vulnerability that could allow an attacker to execute arbitrary code when parsing DVP file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics ISPSoft version 3.20 is vulnerable to a Stack-Based buffer overflow vulnerability that could allow an attacker to leverage debugging logic to execute arbitrary code when parsing. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DRASimuCAD STP File Parsing Type Confusion Remote Code Execution Vulnerability. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DRASimuCAD ICS File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DRASimuCAD STP File Parsing Type Confusion Remote Code Execution Vulnerability. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
If an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overflow in BACnetObjectInfo can be exploited, allowing the. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
If an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overflow in BACnetParameter can be exploited, allowing the. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
If an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overflow in CEtherIPTagItem can be exploited, allowing the. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script AM_RegReport.aspx. Rated critical severity (CVSS 9.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script Handler_CFG.ashx. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Delta Electronics DTN Soft version 2.0.1 and prior are vulnerable to an attacker achieving remote code execution through a deserialization of untrusted data vulnerability. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
A crafted DPA file could force Delta Electronics DIAScreen to overflow a stack-based buffer, which could allow an attacker to execute arbitrary code. Rated high severity (CVSS 8.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateScript' message, which is splitted into 4 fields using the '~' character as. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Delta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
SQL injection vulnerability exists in GetDIAE_usListParameters. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Delta ISPSoft contains an out-of-bounds read (CWE-125) that can crash the application and potentially leak limited memory contents when a user opens a specially crafted project file. Exploitation is client-side and requires user interaction (opening the file on an engineering workstation), not remote access to a listening service, so the practical risk is moderate. No public exploit code has been identified at time of analysis.
Out-of-bounds read in Delta ISPSoft can disclose limited sensitive memory contents and cause a high availability impact when a user opens a specially crafted project or data file. The vulnerability affects installations of the Delta ISPSoft engineering software (CPE cpe:2.3:a:deltaww:ispsoft:*:*:*:*:*:*:*:* indicates no version limitation in the supplied data) and is a client-side file-parsing issue requiring user interaction, not an unattended network service flaw. No public exploit identified at time of analysis; the independent assessment rates it as a moderate-priority, client-side exposure rather than a mass-exploitable server vulnerability.
Path traversal in Delta Electronics DIAEnergie before 1.11.00.022 allows unauthenticated remote attackers to manipulate file paths on the host, with the CVSS vector indicating high integrity and availability impact but no confidentiality impact, which is consistent with arbitrary file writing, overwriting, or deletion rather than file disclosure. Exploitation is rated CVSS 9.1 (AV:N/AC:L/PR:N/UI:N) and requires only network reachability to the DIAEnergie web application - no credentials, user interaction, or non-default configuration are prerequisites. No public exploit code has been identified at time of analysis and there is no CISA KEV listing, so current risk is driven by intrinsic severity and exposure rather than observed exploitation in the wild. The practical threat hinges on exposure: DIAEnergie is a niche industrial energy-management platform typically deployed on segmented OT/enterprise networks, so internet-facing or broadly reachable management interfaces carry the highest risk.
SQL injection in Delta Electronics DIAEnergie before version 1.11.00.022 allows an attacker holding a valid low-privileged account to read from and write to the platform's backend database, putting the confidentiality, integrity, and availability of its operational data at risk. The flaw is network reachable (AV:N), requires only a low-privileged session (PR:L), and needs no user interaction; it is not confirmed as actively exploited (no CISA KEV listing) and no public exploit code has been identified at time of analysis. Delta released the fix in advisory PCSA-2026-00014 alongside a batch of related DIAEnergie flaws, including an authentication bypass (CVE-2026-78308) that could supply the very credentials this SQL injection depends on.
SQL injection in Delta Electronics DIAEnergie versions before 1.11.00.022 lets a remote attacker with any valid low-privileged account (CVSS PR:L) execute arbitrary SQL against the underlying database, resulting in full loss of confidentiality, integrity, and availability (CVE-2026-78309, CWE-89, base score 8.8). The flaw is network-reachable with low attack complexity and no user interaction, so it can be triggered directly over the DIAEnergie web interface, though valid credentials are required and the specific vulnerable parameter or endpoint has not been disclosed in the available data. No public exploit code has been identified and the issue is not listed as confirmed actively exploited (CISA KEV), so the immediate risk is highest for internet- or IT-network-exposed deployments where low-privileged accounts are broadly issued. The advisory from Delta covers this CVE alongside five siblings (CVE-2026-78308 through CVE-2026-78313).
Improper authentication in Delta Electronics DIAEnergie before 1.11.00.022 allows authentication bypass, enabling remote attackers to reach protected functionality without valid credentials. The flaw carries a CVSS 3.1 base score of 9.8 (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H), meaning exploitation requires no authentication, no user interaction, and no non-default configuration - only network reachability to the DIAEnergie service. There is no public exploit identified at time of analysis and no confirmed active exploitation (CISA KEV); the practical exposure is limited chiefly by the product's footprint, as DIAEnergie is a niche ICS energy-management platform typically deployed on operational or enterprise networks rather than the public internet.
SQL injection in Delta DIAEnergie versions up to and including 1.11.00.002 enables low-privileged authenticated remote attackers to achieve full remote code execution on the host system. The flaw (CWE-89) is network-exploitable with low complexity, affecting an industrial energy management platform used in OT environments where RCE carries significant operational risk. No public exploit code or CISA KEV listing has been identified at time of analysis, though the vendor has published a security advisory.
SQL injection in Delta DIAEnergie versions up to and including v1.11.00.002 enables authenticated network-based attackers to achieve remote code execution on the underlying server. Carrying a CVSS base score of 8.8 with low-privilege, low-complexity network access required, this flaw poses serious risk to operational technology environments that depend on this energy management platform for monitoring and control. No public exploit code or CISA KEV listing has been identified at time of analysis, though Delta Electronics has self-disclosed the issue via vendor advisory PCSA-2026-00015.
SQL Injection in Delta Electronics DIAEnergie versions up to and including 1.11.00.002 enables a low-privileged remote attacker to achieve full remote code execution on the underlying server. Confirmed by vendor advisory Delta-PCSA-2026-00015 and ENISA EUVD-2026-64760, the flaw (CWE-89) stems from unsanitized user input passed directly to backend SQL queries, with the database engine serving as the execution bridge to the OS. No public exploit or CISA KEV listing has been identified at time of analysis, but the network-accessible RCE impact in an industrial energy management context elevates this to a high-priority remediation target.
SQL injection in Delta DIAEnergie versions up to and including v1.11.00.002 enables authenticated network-accessible attackers to escalate from data manipulation to remote code execution on the underlying host. Confirmed by vendor advisory Delta PCSA-2026-00015 and EUVD-2026-64759, the vulnerability (CWE-89) carries a CVSS 3.1 score of 8.8, reflecting low attack complexity and full CIA impact. No public exploit or CISA KEV listing has been identified at time of analysis, but the RCE pathway in an energy management system warrants priority remediation.
Denial-of-service exposure in the Delta Electronics DVP80ES3 programmable logic controller (part of the DVP-ES3 series) stems from an improperly implemented standard security check (CWE-358) that a remote, unauthenticated attacker can abuse over the network to force a loss of availability. The CVSS 4.0 base score is 8.7 (High), driven entirely by high availability impact with no confidentiality or integrity impact in the scored vector. There is no public exploit identified at time of analysis and it is not listed in CISA KEV; note that the vendor's tags label this 'Information Disclosure,' which conflicts with the availability-only CVSS vector and should be verified against the Delta advisory.
Denial of service in Delta Electronics DVP80ES3 programmable logic controllers arises from a failure to enforce message integrity on a communication channel (CWE-924), allowing remote, unauthenticated attackers to inject or tamper with protocol messages and disrupt device availability. Per the vendor CVSS vector (AV:N/AC:L/PR:N/UI:N/C:N/I:N/A:H), the confirmed impact is loss of availability of this industrial controller with no privileges or user interaction required. There is no public exploit identified at time of analysis and it is not listed in CISA KEV, though the network-reachable, no-auth profile of an ICS device makes it operationally significant.
Denial of service in Delta Electronics DVP80ES3 programmable logic controllers arises from an improper resource shutdown or release flaw (CWE-404) that lets remote unauthenticated attackers exhaust or corrupt device resources. Per the CVSS vector the impact is limited to availability (A:H) with no confidentiality or integrity loss, meaning a successful attacker can crash or hang the PLC and disrupt the controlled industrial process. No public exploit identified at time of analysis; the issue is documented in Delta advisory Delta-PCSA-2026-00009, which bundles it with CVE-2026-12576 and CVE-2026-12577.
Denial-of-service in the Delta Electronics DVP80ES300T programmable logic controller allows remote unauthenticated attackers to crash the device by triggering an improper array-index validation flaw (CWE-129). Per the CVSS vector the impact is limited to availability (A:H) with no confidentiality or integrity loss, so a successful attack halts PLC operation rather than exposing data. There is no public exploit identified at time of analysis and it is not listed in CISA KEV; EPSS was not provided.
Authentication bypass in the Delta Electronics AS228T programmable logic controller allows remote attackers to circumvent authentication controls and gain unauthorized access to controller functions over the network, threatening the integrity and availability of the industrial process it governs. The CVSS 3.1 base score is 7.4 (High), driven by high integrity and availability impact (I:H/A:H) with no confidentiality loss, but tempered by high attack complexity (AC:H). At the time of analysis there is no public exploit identified and the flaw is not listed in CISA KEV; no EPSS value was supplied.
Arbitrary code execution in Delta Electronics DTMSoft arises from unsafe deserialization of untrusted data during project file parsing (CWE-502), allowing an attacker who supplies a malicious DTMSoft project file to run code in the context of the user who opens it. The flaw is local and requires victim interaction (opening the crafted file) rather than remote network exploitation, and impacts confidentiality, integrity, and availability fully. There is no public exploit identified at time of analysis and the issue is not listed in CISA KEV; no EPSS score was supplied.
Unauthenticated Modbus TCP exposure on the Delta Electronics DVP12SE programmable logic controller lets any network-reachable attacker invoke security-sensitive PLC functions - reading and writing process registers, coils, and configuration - with no credentials or access control. The flaw (CWE-306, Missing Authentication for a Critical Function) carries a CVSS 4.0 base of 9.3 and is documented in Delta advisory PCSA-2026-00011 alongside CVE-2026-12818. There is no public exploit identified at time of analysis and no CISA KEV listing, but the Modbus protocol is trivially scriptable and well understood, lowering the practical exploitation bar.
Resource exhaustion in Delta Electronics DVP12SE programmable logic controllers lets remote attackers crash or hang the device by overwhelming its Modbus TCP service, which lacks connection/resource throttling (CWE-770). Any host able to reach the PLC's Modbus TCP port can degrade or deny control of the affected industrial process. There is no public exploit identified at time of analysis and the issue is not listed in CISA KEV, but the unauthenticated network attack surface makes it a meaningful availability risk in OT environments.
Unchecked directory name buffer in Delta Electronics AS320T enables remote code execution without authentication. The CVSS vector (AV:N/AC:L/PR:N/UI:N) confirms this is a remotely exploitable stack buffer overflow (CWE-121) requiring no user interaction or credentials. Delta Electronics disclosed this vulnerability in security advisory PCSA-2026-00006, affecting an industrial automation product. No EPSS score or KEV status available at time of analysis, but the trivial exploitation requirements (network accessible, no authentication, low complexity) present immediate risk to exposed AS320T devices.
Remote unauthenticated attackers can trigger denial of service in Delta Electronics AS320T industrial automation devices by invoking an undocumented subfunction. The vulnerability allows network-accessible exploitation without credentials against default configurations, potentially disrupting critical industrial control operations. Delta Electronics confirmed the flaw in PCSA-2026-00006, grouped with three other CVEs affecting the same product line.
Remote code execution in Delta Electronics AS320T allows unauthenticated network attackers to exploit an unchecked buffer overflow in filename processing to execute arbitrary code with high impact to confidentiality, integrity, and availability. The CVSS 9.8 critical score reflects network-accessible attack surface with no authentication or user interaction required. No EPSS or KEV data available at time of analysis, but vendor advisory confirms multiple related vulnerabilities affecting the same product line.
Remote code execution in Delta Electronics AS320T industrial automation server allows unauthenticated network attackers to trigger memory corruption via malformed GET/PUT requests to the web service. The incorrect buffer size calculation (CWE-131) enables stack-based overflow attacks against network-exposed management interfaces. With CVSS 9.8 (AV:N/AC:L/PR:N/UI:N) indicating trivial exploitation conditions and CRITICAL severity, this vulnerability represents an immediate risk to industrial control systems deploying this Delta OT product, though no public exploit or active exploitation confirmed at time of analysis.
Stack-based buffer overflow in Delta Electronics ASDA-Soft allows local attackers with no privileges to execute arbitrary code by tricking users into opening a malicious file. The vulnerability achieves complete system compromise (confidentiality, integrity, availability all rated High in CVSS) through user interaction with crafted input. No public exploit identified at time of analysis, though the low attack complexity and lack of required privileges increase realistic exploitation risk once details emerge.
Delta Electronics COMMGR2 has Buffer Over-read DoS vulnerability. [CVSS 7.5 HIGH]
Stack-based buffer overflow in Delta Electronics COMMGR2 communication management software. ICS vulnerability enabling remote code execution on industrial communication gateways.
Arbitrary code execution in Delta Electronics CNCSoft-G2 occurs when the application fails to properly validate user-supplied files, allowing an attacker to execute malicious code by tricking a user into opening a crafted file. This local vulnerability affects industrial environments running CNCSoft-G2 and requires user interaction to exploit. No patch is currently available.
ASDA-Soft Stack-based Buffer Overflow Vulnerability [CVSS 7.8 HIGH]
Delta Electronics DIAView has Command Injection vulnerability. [CVSS 7.8 HIGH]
An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateHDMWYC' message, which is split into 4 fields using the '~' character as the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Improper access control in Delta Electronics DIAEnergie before 1.11.00.022 allows a low-privileged authenticated user to read sensitive data that should be restricted to higher-privilege roles, with network-reachable, low-complexity exploitation that requires no user interaction. The CVSS 3.1 vector (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N, 6.5 Medium) shows the impact is confined to confidentiality - no integrity or availability effect - and the PR:L component means an attacker must already hold at least a valid low-privilege account on the web application rather than being a fully anonymous internet scanner. No public exploit code was identified at time of analysis and the vulnerability is not confirmed as actively exploited (not listed in CISA KEV), so risk is highest for environments where DIAEnergie is network-exposed and accounts are broadly provisioned.
An authorization bypass through a user-controlled key (CWE-639) exists in Delta Electronics DIAEnergie versions before 1.11.00.022, allowing a low-privilege authenticated user to reference objects or records belonging to other users and read data they are not authorized to access. The flaw is network-reachable (AV:N) and requires no victim interaction (UI:N), but exploitation is gated behind a valid low-privilege session (PR:L), so realistic abuse is limited to malicious insiders, legitimate users exceeding their privileges, or attackers who have already obtained credentials; impact is bounded to confidentiality (C:L) with no integrity or availability effect, giving a CVSS 3.1 base score of 4.3. No public exploit code has been identified at time of analysis and the issue is not confirmed actively exploited (CISA KEV), making this a genuine but low-priority weakness rather than a high-severity emergency.
Delta Electronics DIAView has a missing authentication vulnerability that allows remote attackers to access critical functionality without credentials, potentially compromising SCADA monitoring.
Delta Electronics DIAView uses hard-coded cryptographic keys, allowing attackers to forge authentication tokens, decrypt sensitive data, or bypass security controls entirely.
An out-of-bounds memory write in the firmware of the Delta DVP-12SE11T programmable logic controller allows remote attackers to corrupt memory on a network-reachable device, with the supplied CVSS 3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, base 9.8) indicating no authentication or user interaction is required and full loss of confidentiality, integrity, and availability. The flaw is classified as CWE-787 (out-of-bounds write) and is reported against the DVP-12SE11T firmware with no version constraint in the CPE record, meaning all observed firmware builds of that model should be treated as affected until the vendor advisory (Delta PCSA-2025-00022) narrows the range. No public exploit code has been identified at time of analysis and the issue is not listed in CISA KEV; realistic exploitation depends on an attacker first reaching the controller on an OT/plant network segment, since the exact triggering protocol, port, or message type is not disclosed in the available data.
Denial of service in Delta Electronics DVP-12SE11T PLC firmware lets an unauthenticated, remote attacker crash or otherwise render the device unavailable (CVSS 3.1 base 7.5, AV:N/AC:L/PR:N/UI:N with availability-only impact). The vulnerability stems from improper input validation (CWE-20) in the device's exposed network service, and the CPE entry cpe:2.3:o:deltaww:dvp-12se11t_firmware:* indicates all observed firmware versions are affected. Risk is moderate rather than critical: EPSS is 0.32% (23rd percentile), there is no CISA KEV listing and no public exploit identified at time of analysis, and the practical barrier is network reachability - the device is normally deployed inside segmented or air-gapped OT networks, where no authentication or user interaction is required once the attacker can reach the service.
Authentication bypass in Delta DVP-12SE11T PLC firmware allows unauthenticated remote attackers to fully compromise the device via partial password disclosure. The vulnerability is network-reachable, requires no credentials or user interaction, and can lead to complete loss of confidentiality, integrity, and availability. No public exploit code or active exploitation has been identified at time of analysis.
Authentication bypass in Delta DVP-12SE11T PLCs allows remote, unauthenticated attackers to fully compromise the controller’s confidentiality, integrity, and availability (CVSS 9.8). The flaw (CWE-288) leverages an alternate authentication path in the firmware, requiring network access to the device's engineering or communication interface and no user interaction. No public exploit identified at time of analysis; exploitation is primarily limited by OT network segmentation and firewalling.
An out-of-bounds write in Delta Electronics DIAScreen before 1.6.1 lets attackers execute code in the context of the current process when a victim opens a specially crafted project file. The flaw is a file-parsing validation failure (CWE-787) that is strictly client-side: exploitation is local (AV:L) and requires the operator to actively open a malicious file, so there is no remote or unattended attack path. No public exploit code has been identified at time of analysis and EPSS is negligible (0.02%, 3rd percentile), making real-world risk low despite the code-execution potential.
An out-of-bounds write in the file-parsing routine of Delta Electronics DIAScreen (all versions prior to 1.6.1) allows code execution in the context of the current DIAScreen process when a user opens an attacker-crafted project file. The CVSS v4.0 vector is local (AV:L) with PR:N - unauthenticated - but requires active user interaction (UI:A), so the attacker must first deliver a malicious file to an engineering workstation and convince an operator to open it; there is no remote or network-triggered path. No public exploit code has been identified at time of analysis (no CISA KEV listing), and the EPSS score is only 0.02% (3rd percentile), which aligns with our independent assessment that this is a moderate, not high-priority, issue for most environments, though the high availability impact (memory corruption/crash) makes even failed exploitation disruptive on production engineering hosts.
An out-of-bounds write in Delta Electronics DIAScreen's file-parsing routine (all versions from 0 through 1.6.1) allows an attacker to execute code in the context of the current user's process when an engineer or operator opens a crafted project/configuration file. The flaw is exploitable without authentication (CVSS 4.0 vector PR:N) but is strictly local and requires the victim to be socially engineered into opening the malicious file (UI:A), so there is no drive-by, network-reachable, or self-propagating path, and impact stays bounded to the victim's own privileges (S:U, SC:N/SI:N/SA:N). Risk signals point to low real-world urgency: EPSS is only 0.02% (3rd percentile), there is no CISA KEV entry, and no public exploit code has been identified at time of analysis. Delta has released a vendor patch in DIAScreen 1.6.1.
An out-of-bounds write in the file-parsing routines of Delta Electronics DIAScreen (versions prior to 1.6.1) allows a crafted project file to corrupt memory and execute code in the context of the DIAScreen process when a user opens it. Exploitation is local and user-interaction driven: the attacker must deliver a malicious file and induce the victim to open it, so social engineering, not network reachability, is the limiting factor - no pre-existing credentials in the application are needed (PR:N in the assessed vector), but the attack hinges on a user opening the file (UI:A, UI:R in the CVSS 3.1 assessment). Delta has published a fixed build (1.6.1), EPSS is 0.02% (3rd percentile), and no public exploit code has been identified at time of analysis.
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. Rated high severity (CVSS 7.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
DIAEnergie - Reflected Cross-site Scripting. Rated medium severity (CVSS 5.9), this vulnerability is remotely exploitable. No vendor patch available.
DIAEnergie - Reflected Cross-site Scripting. Rated medium severity (CVSS 5.9), this vulnerability is remotely exploitable. No vendor patch available.
DIAEnergie - Reflected Cross-site Scripting. Rated medium severity (CVSS 5.9), this vulnerability is remotely exploitable. No vendor patch available.
DIAEnergie - Stored Cross-site Scripting. Rated high severity (CVSS 7.0), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Local code execution vulnerability in Delta Electronics CNCSoft-G2 resulting from insufficient file validation when processing user-supplied files. An authenticated local attacker can craft a malicious file that, when opened by a user, executes arbitrary code with the privileges of the affected application. This vulnerability has a CVSS score of 7.3 (High) and requires local access and user interaction, making it a significant risk for organizations deploying CNCSoft-G2 in manufacturing or industrial control environments.
Local code execution vulnerability in Delta Electronics CNCSoft caused by insufficient validation of user-supplied files. When a user opens a malicious file, an attacker can execute arbitrary code with the privileges of the current process. While no publicly disclosed POC or active exploitation in the wild has been confirmed, the high CVSS score (7.3) and the file-opening attack vector present moderate risk to users of affected CNCSoft versions.
Buffer overflow vulnerability (CWE-787) in Delta Electronics CNCSoft that allows local authenticated users to execute arbitrary code by opening a specially crafted malicious file. The vulnerability requires user interaction (file opening) but results in complete compromise of the affected process with high impact to confidentiality, integrity, and availability. No KEV status, EPSS score, or confirmed active exploitation data is available in the provided intelligence.
Local arbitrary code execution vulnerability in Delta Electronics CNCSoft caused by insufficient validation of user-supplied files. An attacker with local access can craft a malicious file that, when opened by a user, executes arbitrary code with the privileges of the CNCSoft process. With a CVSS score of 7.3 and CWE-787 (Out-of-bounds Write) classification, this represents a significant local privilege escalation risk, though exploitation requires user interaction and local access.
Local privilege escalation vulnerability in Delta Electronics CNCSoft caused by insufficient validation of user-supplied files. When a user opens a malicious file, an attacker can execute arbitrary code with the privileges of the current process. While the CVSS score of 7.3 is moderate-to-high, the attack requires local access and user interaction, limiting immediate widespread impact; however, the high integrity and confidentiality impact (CWE-787: Out-of-bounds Write) warrants prompt patching.
Delta Electronics ISPSoft version 3.20 is vulnerable to an Out-Of-Bounds Write vulnerability that could allow an attacker to execute arbitrary code when parsing ISP file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics ISPSoft version 3.20 is vulnerable to an Out-Of-Bounds Write vulnerability that could allow an attacker to execute arbitrary code when parsing ISP file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics ISPSoft version 3.20 is vulnerable to a Stack-Based buffer overflow vulnerability that could allow an attacker to execute arbitrary code when parsing DVP file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics ISPSoft version 3.20 is vulnerable to an Out-Of-Bounds Write vulnerability that could allow an attacker to execute arbitrary code when parsing DVP file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics ISPSoft version 3.20 is vulnerable to a Stack-Based buffer overflow vulnerability that could allow an attacker to leverage debugging logic to execute arbitrary code when parsing. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DRASimuCAD STP File Parsing Type Confusion Remote Code Execution Vulnerability. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DRASimuCAD ICS File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DRASimuCAD STP File Parsing Type Confusion Remote Code Execution Vulnerability. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
If an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overflow in BACnetObjectInfo can be exploited, allowing the. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
If an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overflow in BACnetParameter can be exploited, allowing the. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
If an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overflow in CEtherIPTagItem can be exploited, allowing the. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script AM_RegReport.aspx. Rated critical severity (CVSS 9.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script Handler_CFG.ashx. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Delta Electronics DTN Soft version 2.0.1 and prior are vulnerable to an attacker achieving remote code execution through a deserialization of untrusted data vulnerability. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
A crafted DPA file could force Delta Electronics DIAScreen to overflow a stack-based buffer, which could allow an attacker to execute arbitrary code. Rated high severity (CVSS 8.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Rated high severity (CVSS 8.4), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateScript' message, which is splitted into 4 fields using the '~' character as. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Delta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
SQL injection vulnerability exists in GetDIAE_usListParameters. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.