Skip to main content

Delta DIAEnergie CVE-2026-78317

| EUVDEUVD-2026-64762 HIGH
SQL Injection (CWE-89)
2026-08-24 Deltaww GHSA-prhw-g95g-hmrw
8.8
CVSS 3.1 · Vendor: Deltaww
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Obtain low-privilege DIAEnergie credentials
  2. Delivery
    Send crafted HTTP request with SQL payload
  3. Exploit
    Inject SQL into server-side database query
  4. Execution
    Leverage database engine to execute OS commands
  5. Impact
    Achieve remote code execution on DIAEnergie host

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Parameterized queries, prepared statements
MITRE ATT&CK

2 techniques across 2 tactics: Initial Access, Persistence

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires a valid low-privilege account on the DIAEnergie application (confirmed by CVSS PR:L). The application must be network-reachable by the attacker (AV:N, AC:L). No user interaction from a victim is required (UI:N). The scope is unchanged (S:U), meaning exploitation is confined to the DIAEnergie host itself. Limiting factors: an attacker without any DIAEnergie credentials cannot exploit this remotely; default or weak credentials would satisfy the PR:L requirement and should be treated as a heightened risk. No specific non-default configuration is described as a prerequisite - the flaw appears to exist in core functionality. The OT/ICS deployment context limits prevalence of internet-exposed instances, but internal network or VPN access is a realistic attacker position in industrial environments.

Impact

The CVSS 3.1 score of 8.8 (High) reflects network accessibility, low attack complexity, low privilege requirement, and full confidentiality, integrity, and availability impact. The PR:L metric is significant: exploitation is gated behind authentication, which meaningfully reduces the exposed attack surface compared to unauthenticated (PR:N) vectors, but insider threats, stolen credentials, or default credential abuse all satisfy this prerequisite. No EPSS data was provided in the source intelligence; without it, probabilistic exploitation likelihood cannot be independently stated. No KEV listing is present, and no POC is referenced, so no confirmed active exploitation is known. The combination of network reachability, low complexity, and RCE impact makes this a genuine remediation priority for any organization running DIAEnergie - particularly given the OT/ICS deployment context where operational disruption is a material concern. The absence of a named fixed version in the available data is a data gap that should be resolved by consulting the vendor advisory directly before finalizing remediation planning.

Exploit ScenarioDerived

An attacker with any valid low-privilege account on the DIAEnergie platform sends a crafted HTTP request containing a malicious SQL payload to a vulnerable application endpoint. The unsanitized input is executed within the database engine, which is then leveraged to spawn OS-level commands - for example via a stored procedure or linked server capability - resulting in arbitrary code execution under the database service account on the DIAEnergie server. No public POC has been identified at time of analysis, but the straightforward nature of the attack chain (authenticated SQL injection to RCE) is well-understood and reproducible by moderately skilled attackers.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.7% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Aug 24, 2026

SQL injection in Delta DIAEnergie versions up to and including 1.11.00.002 enables low-privileged authenticated remote attackers to achieve full remote code execution on the host system. The flaw (CWE-89) is network-exploitable with low complexity, affecting an industrial energy management platform used in OT environments where RCE carries significant operational risk. No public exploit code or CISA KEV listing has been identified at time of analysis, though the vendor has published a security advisory.

RemediationAI

Consult the Delta Electronics advisory PCSA-2026-00015 (https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00015_DIAEnergie%20SQL%20Injection%20Vulberabilities_v1.0.pdf) for the official patched version; no specific fix version number is named in the available intelligence, so the advisory PDF must be reviewed directly to obtain the exact upgrade target. Patch available per vendor advisory - upgrade DIAEnergie to the version specified therein. As a compensating control pending patching, restrict network access to the DIAEnergie application server using firewall rules or network segmentation so that only authorized users and systems can reach it; this does not eliminate the vulnerability but raises the bar for exploitation by reducing exposure to untrusted users. Additionally, enforce least-privilege account controls and audit all accounts with access to the DIAEnergie interface to reduce the pool of credentials that satisfy the PR:L prerequisite. Disabling OS-command execution capabilities in the underlying database engine (e.g., disabling xp_cmdshell on MSSQL) may limit RCE impact even if SQL injection occurs, but does not remediate the underlying injection flaw.

Affected VersionsENISA

DIAEnergie 0 ≤1.11.00.002

Affected Packages

euvd diaenergie no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

DIAEnergie (CPE: cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*) is Delta Electronics' industrial energy management system, typically deployed in OT/ICS environments for monitoring and managing energy consumption. CWE-89 (Improper Neutralization of Special Elements used in an SQL Command) indicates that user-supplied input is incorporated directly into SQL queries without adequate sanitization or parameterization. In server-side energy management applications, SQL injection frequently leads to RCE when the underlying database engine supports procedural extensions capable of spawning OS processes (e.g., MSSQL's xp_cmdshell or equivalent mechanisms). The CVSS vector AV:N/AC:L/PR:L confirms the flaw is reachable over the network by any authenticated user without elevated privileges.

Know when Diaenergie gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (Deltaww) PRIMARY 8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
vuln.today AI 8.8 HIGH

Network-reachable SQL injection requiring only low-privilege authentication; full C/I/A impact via RCE; no scope change beyond the vulnerable host.

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (Deltaww).

CVSS VectorVendor: Deltaww

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionCVE.org

SQL Injection in Delta DIAEnergie v1.11.00.002 allows attacker to remote code execution.

Executive ViewAI

Why It Matters

Delta DIAEnergie industrial energy management platform (versions up to 1.11.00.002) contains a critical SQL injection vulnerability enabling remote code execution on affected systems. This directly threatens operational continuity and system integrity for organizations relying on this platform, particularly in energy sectors where unavailability carries severe business consequences. No vendor-released patch is available at time of analysis, requiring immediate interim mitigation.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Deploy network-level access restrictions limiting connectivity to authorized administrative users only. Enforce strong authentication on all system accounts with multi-factor authentication where supported. Enable detailed database query logging and real-time monitoring for SQL injection patterns. Deploy Web Application Firewall rules blocking known SQL injection attack vectors if the system accepts external input. Maintain isolated, tested backup systems available for rapid recovery. Coordinate with vendor on interim security advisories that may contain application-level detection or filtering measures.

Threat Intelligence Overview

EPSS Score
0.7%
Top 51% exploitable
Prevalence
Low
niche industrial energy management system, OT/ICS sector
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.7%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

45
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +44
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

SQL injection exploits the way applications construct database queries by mixing user input directly into SQL statements.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

CVE-2024-4548 CRITICAL POC
9.8 May 06

An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalcula

CVE-2024-4547 CRITICAL POC
9.8 May 06

A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalculat

CVE-2024-4549 HIGH POC
7.5 May 06

A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. Rated high severity (CV

CVE-2022-33005 MEDIUM POC
6.1 Jun 27

A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1

CVE-2026-78308 CRITICAL
9.8 Sep 24

Improper authentication in Delta Electronics DIAEnergie before 1.11.00.022 allows authentication bypass, enabling remote

CVE-2024-25574 CRITICAL
9.8 Apr 01

SQL injection vulnerability exists in GetDIAE_usListParameters. Rated critical severity (CVSS 9.8), this vulnerability i

CVE-2022-43775 CRITICAL
9.8 Oct 26

The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to ga

CVE-2022-43774 CRITICAL
9.8 Oct 26

The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacke

CVE-2022-3214 CRITICAL
9.8 Sep 16

Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-c

CVE-2022-1378 CRITICAL
9.8 May 02

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p

CVE-2022-1377 CRITICAL
9.8 May 02

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_r

CVE-2022-1376 CRITICAL
9.8 May 02

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy