Diaenergie
CVE-2024-4547
CRITICAL
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from Vendor (tenable) · only source for this CVE.
CVSS VectorVendor: tenable
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionCVE.org
A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateScript' message, which is splitted into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field
AnalysisAI
A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateScript' message, which is splitted into 4 fields using the '~' character as. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-20. A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateScript' message, which is splitted into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field Affected products include: Deltaww Diaenergie.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
More in Diaenergie
View allAn SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalcula
A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. Rated high severity (CV
A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1
SQL injection vulnerability exists in GetDIAE_usListParameters. Rated critical severity (CVSS 9.8), this vulnerability i
The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to ga
The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacke
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-c
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_r
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_s
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_u
Same weakness CWE-20 – Improper Input Validation