Skip to main content

DIAEnergie CVE-2026-78316

| EUVDEUVD-2026-64761 HIGH
SQL Injection (CWE-89)
2026-08-24 Deltaww GHSA-h94p-9wc2-8mj4
8.8
CVSS 3.1 · Vendor: Deltaww
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Recon
    Obtain low-privilege DIAEnergie credentials
  2. Delivery
    Send crafted SQL payload over network
  3. Exploit
    Inject into unsanitized query parameter
  4. Install
    Manipulate backend SQL execution
  5. C2
    Invoke database OS-command execution feature
  6. Execute
    Execute arbitrary commands as database service account
  7. Impact
    Full server compromise

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Parameterized queries, prepared statements
MITRE ATT&CK

2 techniques across 2 tactics: Initial Access, Persistence

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

The CVSS PR:L metric confirms that a valid low-privilege DIAEnergie application account is required - unauthenticated exploitation is not supported by the available data. Beyond that credential requirement, attack complexity is low (AC:L), meaning no race condition, specific timing, or complex multi-step pre-condition is necessary. The attack is delivered over the network (AV:N) with no user interaction required. The specific vulnerable parameter or endpoint is not named in the available advisory summary; full technical details require review of the vendor advisory PDF. Exploitation is bounded by the need for at least one application credential and by whether the underlying database service has OS-command execution capabilities enabled; if those database features are disabled, the impact may be limited to data exfiltration and integrity loss rather than full RCE.

Impact

The CVSS 3.1 vector (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) scores 8.8, reflecting network-accessible exploitation with low attack complexity and only low-privilege credentials required - a combination historically associated with rapid weaponization once disclosed. No EPSS score is present in the available data, which limits probabilistic exploitation forecasting; the absence of a CISA KEV listing means active exploitation is not confirmed, but this should not be taken as evidence of safety given the OT context. The RCE-class outcome of an SQL injection vulnerability in industrial energy management software means a successful attack could disrupt energy monitoring, manipulate operational data, or serve as a pivot into segmented OT networks. The PR:L requirement does provide a meaningful limit: attackers must possess at least one valid application credential, reducing but not eliminating exposure, particularly in environments with broadly provisioned user accounts.

Exploit ScenarioDerived

An attacker holding a low-privilege DIAEnergie account submits a crafted SQL payload through a vulnerable application parameter over the network. The unsanitized input reaches the backend database, where the attacker leverages a database command-execution mechanism to issue operating system commands under the database service account context. This results in full server compromise and potential lateral movement into the broader OT network infrastructure.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.7% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Aug 24, 2026

SQL injection in Delta DIAEnergie versions up to and including v1.11.00.002 enables authenticated network-based attackers to achieve remote code execution on the underlying server. Carrying a CVSS base score of 8.8 with low-privilege, low-complexity network access required, this flaw poses serious risk to operational technology environments that depend on this energy management platform for monitoring and control. No public exploit code or CISA KEV listing has been identified at time of analysis, though Delta Electronics has self-disclosed the issue via vendor advisory PCSA-2026-00015.

RemediationAI

Consult Delta's advisory PCSA-2026-00015 at https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00015_DIAEnergie%20SQL%20Injection%20Vulberabilities_v1.0.pdf for the official patched release; an exact patched version number was not independently confirmed from available intelligence beyond the advisory reference itself. As a compensating control before patching, restrict network access to the DIAEnergie interface using firewall rules or VLAN segmentation so only authorized management hosts can reach the application - this reduces the attacker pool but does not eliminate risk from insider threats or compromised credentials. Additionally, audit and minimize the set of accounts with any level of DIAEnergie application access, and review whether the database backend has OS-level execution features (e.g., xp_cmdshell) enabled, disabling them if not required, which would break the SQL injection to RCE chain even if the injection itself is triggered.

Affected VersionsENISA

DIAEnergie 0 ≤1.11.00.002

Affected Packages

euvd diaenergie no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

DIAEnergie is an energy management system developed by Delta Electronics (deltaww), typically deployed in industrial and OT environments to monitor and manage energy consumption across facilities. The root cause is CWE-89 (Improper Neutralization of Special Elements used in an SQL Command): user-controlled input reaches backend SQL queries without adequate sanitization, allowing attackers to manipulate query logic. In severe SQL injection chains of this class - particularly against databases exposing OS-level execution features such as xp_cmdshell on Microsoft SQL Server or stacked-query abuse - arbitrary operating system commands can be executed under the database service account, explaining the RCE classification. The CPE cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:* confirms all releases through v1.11.00.002 are within scope per ENISA EUVD-2026-64761.

Know when Diaenergie gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (Deltaww) PRIMARY 8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
vuln.today AI 8.8 HIGH

Network-accessible SQL injection exploitable with low-privilege credentials; high C/I/A reflects RCE capability; no scope change as OT pivot is not confirmed in description.

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (Deltaww).

CVSS VectorVendor: Deltaww

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionCVE.org

SQL Injection in Delta DIAEnergie v1.11.00.002 allows attacker to remote code execution.

Executive ViewAI

Why It Matters

Delta DIAEnergie energy management platform (versions ≤v1.11.00.002) contains a high-severity SQL injection vulnerability enabling remote code execution on the underlying server. The vulnerability requires authenticated network access and no public exploit has been identified at time of analysis, but Delta's self-disclosure creates awareness that threat actors will investigate the flaw. Organizations using DIAEnergie for critical energy infrastructure monitoring and control face operational technology risk if their environments are not properly isolated and access-controlled.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations: Restrict DIAEnergie management interface access to dedicated administrative networks using network segmentation and firewall rules; enforce multi-factor authentication for all administrative accounts; deploy database activity monitoring and web application firewall rules to detect and block SQL injection patterns; enforce least-privilege database user credentials with minimal required permissions; maintain comprehensive audit logging with alerting on abnormal database query patterns and privileged administrative access.

Threat Intelligence Overview

EPSS Score
0.7%
Top 51% exploitable
Prevalence
Low
niche industrial energy management software, OT sector deployment
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.7%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

45
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +44
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

SQL injection exploits the way applications construct database queries by mixing user input directly into SQL statements.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

CVE-2024-4548 CRITICAL POC
9.8 May 06

An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalcula

CVE-2024-4547 CRITICAL POC
9.8 May 06

A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalculat

CVE-2024-4549 HIGH POC
7.5 May 06

A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. Rated high severity (CV

CVE-2022-33005 MEDIUM POC
6.1 Jun 27

A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1

CVE-2026-78308 CRITICAL
9.8 Sep 24

Improper authentication in Delta Electronics DIAEnergie before 1.11.00.022 allows authentication bypass, enabling remote

CVE-2024-25574 CRITICAL
9.8 Apr 01

SQL injection vulnerability exists in GetDIAE_usListParameters. Rated critical severity (CVSS 9.8), this vulnerability i

CVE-2022-43775 CRITICAL
9.8 Oct 26

The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to ga

CVE-2022-43774 CRITICAL
9.8 Oct 26

The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacke

CVE-2022-3214 CRITICAL
9.8 Sep 16

Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-c

CVE-2022-1378 CRITICAL
9.8 May 02

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p

CVE-2022-1377 CRITICAL
9.8 May 02

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_r

CVE-2022-1376 CRITICAL
9.8 May 02

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy