Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
ReconObtain low-privilege DIAEnergie credentials
-
DeliverySend crafted SQL payload over network
-
ExploitInject into unsanitized query parameter
-
InstallManipulate backend SQL execution
-
C2Invoke database OS-command execution feature
-
ExecuteExecute arbitrary commands as database service account
-
ImpactFull server compromise
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Parameterized queries, prepared statements
MITRE ATT&CK
2 techniques across 2 tactics: Initial Access, Persistence The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | The CVSS PR:L metric confirms that a valid low-privilege DIAEnergie application account is required - unauthenticated exploitation is not supported by the available data. Beyond that credential requirement, attack complexity is low (AC:L), meaning no race condition, specific timing, or complex multi-step pre-condition is necessary. The attack is delivered over the network (AV:N) with no user interaction required. The specific vulnerable parameter or endpoint is not named in the available advisory summary; full technical details require review of the vendor advisory PDF. Exploitation is bounded by the need for at least one application credential and by whether the underlying database service has OS-command execution capabilities enabled; if those database features are disabled, the impact may be limited to data exfiltration and integrity loss rather than full RCE. |
| Impact | The CVSS 3.1 vector (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) scores 8.8, reflecting network-accessible exploitation with low attack complexity and only low-privilege credentials required - a combination historically associated with rapid weaponization once disclosed. No EPSS score is present in the available data, which limits probabilistic exploitation forecasting; the absence of a CISA KEV listing means active exploitation is not confirmed, but this should not be taken as evidence of safety given the OT context. The RCE-class outcome of an SQL injection vulnerability in industrial energy management software means a successful attack could disrupt energy monitoring, manipulate operational data, or serve as a pivot into segmented OT networks. The PR:L requirement does provide a meaningful limit: attackers must possess at least one valid application credential, reducing but not eliminating exposure, particularly in environments with broadly provisioned user accounts. |
| Exploit ScenarioDerived | An attacker holding a low-privilege DIAEnergie account submits a crafted SQL payload through a vulnerable application parameter over the network. The unsanitized input reaches the backend database, where the attacker leverages a database command-execution mechanism to issue operating system commands under the database service account context. This results in full server compromise and potential lateral movement into the broader OT network infrastructure. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Aug 24, 2026
SQL injection in Delta DIAEnergie versions up to and including v1.11.00.002 enables authenticated network-based attackers to achieve remote code execution on the underlying server. Carrying a CVSS base score of 8.8 with low-privilege, low-complexity network access required, this flaw poses serious risk to operational technology environments that depend on this energy management platform for monitoring and control. No public exploit code or CISA KEV listing has been identified at time of analysis, though Delta Electronics has self-disclosed the issue via vendor advisory PCSA-2026-00015.
RemediationAI
Consult Delta's advisory PCSA-2026-00015 at https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00015_DIAEnergie%20SQL%20Injection%20Vulberabilities_v1.0.pdf for the official patched release; an exact patched version number was not independently confirmed from available intelligence beyond the advisory reference itself. As a compensating control before patching, restrict network access to the DIAEnergie interface using firewall rules or VLAN segmentation so only authorized management hosts can reach the application - this reduces the attacker pool but does not eliminate risk from insider threats or compromised credentials. Additionally, audit and minimize the set of accounts with any level of DIAEnergie application access, and review whether the database backend has OS-level execution features (e.g., xp_cmdshell) enabled, disabling them if not required, which would break the SQL injection to RCE chain even if the injection itself is triggered.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
DIAEnergie is an energy management system developed by Delta Electronics (deltaww), typically deployed in industrial and OT environments to monitor and manage energy consumption across facilities. The root cause is CWE-89 (Improper Neutralization of Special Elements used in an SQL Command): user-controlled input reaches backend SQL queries without adequate sanitization, allowing attackers to manipulate query logic. In severe SQL injection chains of this class - particularly against databases exposing OS-level execution features such as xp_cmdshell on Microsoft SQL Server or stacked-query abuse - arbitrary operating system commands can be executed under the database service account, explaining the RCE classification. The CPE cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:* confirms all releases through v1.11.00.002 are within scope per ENISA EUVD-2026-64761.
Know when Diaenergie gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Network-accessible SQL injection exploitable with low-privilege credentials; high C/I/A reflects RCE capability; no scope change as OT pivot is not confirmed in description.
Primary rating from Vendor (Deltaww).
CVSS VectorVendor: Deltaww
DescriptionCVE.org
SQL Injection in Delta DIAEnergie v1.11.00.002 allows attacker to remote code execution.
Executive ViewAI
Delta DIAEnergie energy management platform (versions ≤v1.11.00.002) contains a high-severity SQL injection vulnerability enabling remote code execution on the underlying server. The vulnerability requires authenticated network access and no public exploit has been identified at time of analysis, but Delta's self-disclosure creates awareness that threat actors will investigate the flaw. Organizations using DIAEnergie for critical energy infrastructure monitoring and control face operational technology risk if their environments are not properly isolated and access-controlled.
No vendor-released patch identified at time of analysis. Interim mitigations: Restrict DIAEnergie management interface access to dedicated administrative networks using network segmentation and firewall rules; enforce multi-factor authentication for all administrative accounts; deploy database activity monitoring and web application firewall rules to detect and block SQL injection patterns; enforce least-privilege database user credentials with minimal required permissions; maintain comprehensive audit logging with alerting on abnormal database query patterns and privileged administrative access.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
SQL injection exploits the way applications construct database queries by mixing user input directly into SQL statements.
Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.
More in Diaenergie
View allAn SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalcula
A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalculat
A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. Rated high severity (CV
A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1
Improper authentication in Delta Electronics DIAEnergie before 1.11.00.022 allows authentication bypass, enabling remote
SQL injection vulnerability exists in GetDIAE_usListParameters. Rated critical severity (CVSS 9.8), this vulnerability i
The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to ga
The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacke
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-c
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_r
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p
EUVD-2026-64761
GHSA-h94p-9wc2-8mj4
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB