Skip to main content

DIAEnergie CVE-2026-78311

| EUVDEUVD-2026-85820 HIGH
SQL Injection (CWE-89)
2026-09-24 Deltaww GHSA-ccmx-8vcq-6rh5
8.8
CVSS 3.1 · Vendor: Deltaww
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate with low-privilege account
  2. Delivery
    Send crafted HTTP request with SQL payload
  3. Exploit
    Injection executes in backend database
  4. Execution
    Read or modify arbitrary records
  5. Impact
    Full database compromise

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Parameterized queries, prepared statements
MITRE ATT&CK

2 techniques across 2 tactics: Initial Access, Persistence

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Requires a valid low-privileged authenticated session on the DIAEnergie web application (PR:L) reachable over the network; no user interaction is needed. The exact vulnerable input is not disclosed in the advisory, so defenders cannot pin the injection to a specific feature or endpoint from available data. The primary limiting factor is the authentication requirement - an attacker must already possess or obtain valid credentials, though this barrier is weakened where DIAEnergie is exposed and where the companion auth-bypass (CVE-2026-78308) from the same PCSA-2026-00014 batch could supply access. Upgrading to DIAEnergie 1.11.00.022 or later remediates the issue.

Impact

This is a genuine, actionable priority for organizations running DIAEnergie, though not a drop-everything emergency. The vendor CVSS 3.1 vector (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H = 8.8) describes a network-reachable, low-complexity SQL injection requiring only low-privilege authentication and no user interaction, yielding full confidentiality, integrity, and availability impact - consistent with a classic CWE-89 flaw where an authenticated application user can escalate to full database compromise. However, several risk-tempering signals are missing: there is NO EPSS score provided, the CVE is NOT on the CISA KEV list, and no public exploit code (POC) has been identified. Exploitation status is therefore 'no public exploit identified at time of analysis' - do not treat this as actively exploited. The single-source, self-reported nature (Delta's own PCSA advisory) means CVSS is vendor-assigned and not independently corroborated by NVD analysis. Net: the technical severity is real and the 8.8 is defensible, but the PR:L requirement (a valid low-privileged account) plus the lack of exploitation evidence places this as high-but-not-critical operational risk, weighted by the fact that DIAEnergie is deployed in industrial/energy environments where such compromise can affect operational data. DIAEnergie has a history of frequent SQL injection findings and prior CISA ICS advisories, which raises the baseline likelihood that a working exploit will eventually surface.

Exploit ScenarioDerived

An attacker with a valid low-privilege DIAEnergie account (or one obtained via a companion flaw such as the auth-bypass CVE-2026-78308 in the same advisory batch) sends a crafted HTTP request containing malicious SQL through a vulnerable parameter. The injected query executes against the backend database, letting the attacker read, modify, or destroy stored energy-management data and potentially achieve deeper system access. No public exploit code is currently available, but the low attack complexity makes weaponization straightforward once endpoint details are known.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
Patch available 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Sep 24, 2026

SQL injection in Delta Electronics DIAEnergie before version 1.11.00.022 allows an attacker holding a valid low-privileged account to read from and write to the platform's backend database, putting the confidentiality, integrity, and availability of its operational data at risk. The flaw is network reachable (AV:N), requires only a low-privileged session (PR:L), and needs no user interaction; it is not confirmed as actively exploited (no CISA KEV listing) and no public exploit code has been identified at time of analysis. Delta released the fix in advisory PCSA-2026-00014 alongside a batch of related DIAEnergie flaws, including an authentication bypass (CVE-2026-78308) that could supply the very credentials this SQL injection depends on.

RemediationAI

The primary fix is to upgrade DIAEnergie to version 1.11.00.022 or later, the vendor-released patch documented in Delta's PCSA-2026-00014 advisory at https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00014_DIAEnergie%20Multiple%20Vulberabilities%20(CVE-2026-78308%20~%2078313).pdf, which addresses this SQL injection together with the sibling DIAEnergie flaws from the same batch. Because exploitation requires a valid low-privileged session, interim compensating controls should target the authentication and exposure barrier rather than the injection itself: place DIAEnergie behind a VPN or restrict it to trusted management networks and firewall off direct internet access (trade-off: reduced convenience for remote operators and third-party integrators, and a possible need for jump hosts); enforce least-privilege accounts, purge dormant or shared logins, and rotate credentials, enabling MFA where the product supports it (trade-off: added account administration overhead and potential workflow friction for shift staff). Note that the same advisory batch includes an authentication bypass (CVE-2026-78308), so credential hygiene and network segmentation alone are not reliable substitutes for patching, and defenders should monitor database and application logs for anomalous query patterns, SQL error bursts, or unusual data access as a detective control where the fix cannot be applied immediately.

Affected VersionsENISA

DIAEnergie 0 <1.11.00.022

Affected Packages

euvd diaenergie fix: 1.11.00.022

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

DIAEnergie is Delta Electronics' industrial energy management and HMI/SCADA-adjacent software used to monitor, visualize, and analyze power consumption across industrial facilities; the CPE cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:* confirms the entire pre-1.11.00.022 release line is in scope. The root cause is CWE-89, improper neutralization of special elements used in an SQL command: the web application builds database queries from user-supplied input without adequate parameterization or escaping, so an authenticated user can append or restructure SQL statements executed against the backend database. The assessed vector CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H indicates low attack complexity from the network once any account is held, no user interaction, and high impact across confidentiality, integrity, and availability, while the scope remains unchanged (S:U), meaning the damage is contained to the application and its data store rather than extending to the host or adjacent systems. That combination supports data exfiltration, tampering with energy/process records, and denial of service through destructive or resource-intensive queries. The vendor advisory does not disclose the specific vulnerable parameter or endpoint, so defenders cannot pin the injection to a named feature from available data; the remediation is delivered as a version bump rather than a documented query-level change, which points to input-handling fixes in the web application layer. Notably, this CVE is part of the PCSA-2026-00014 batch (CVE-2026-78308 through CVE-2026-78313), and the companion authentication-bypass issue materially weakens the PR:L prerequisite by potentially handing an unauthenticated attacker the session this injection requires.

Know when Diaenergie gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (Deltaww) PRIMARY 8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
vuln.today AI 8.8 HIGH

Network-reachable low-complexity SQLi needing an authenticated low-priv account (PR:L); classic CWE-89 grants full DB read/write/destroy, so C:H/I:H/A:H, scope unchanged.

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (Deltaww).

CVSS VectorVendor: Deltaww

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
Patch available
Sep 24, 2026 - 10:01 EUVD
CVE Published
Sep 24, 2026 - 08:42 cve.org
HIGH 8.8

DescriptionCVE.org

SQL Injection vulnerability in DIAEnergie.

This issue affects DIAEnergie: before 1.11.00.022.

Executive ViewAI

Why It Matters

Delta Electronics DIAEnergie, the industrial energy management platform used to collect and act on operational energy data, is exposed to a database injection flaw that any holder of a low-privileged account could use to read and alter backend operational records. Because the flaw is network-reachable and requires no user interaction, a single shared or compromised operator credential could translate into broad unauthorized changes to the data leadership depends on for operational and compliance reporting. Delta has published a fix in version 1.11.00.022 under advisory PCSA-2026-00014, so the exposure is closable through a managed upgrade rather than an architectural change.

Business Impact: High
Compensating Controls

Apply vendor patch (upgrade to 1.11.00.022).

Threat Intelligence Overview

EPSS Score
0.2%
Top 87% exploitable
Prevalence
Low
niche ICS energy-management software, industry-specific deployment footprint
Social Media
2
Sightings
Data Quality
6 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.2%
Patch available Yes
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

44
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +44
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

SQL injection exploits the way applications construct database queries by mixing user input directly into SQL statements.

CVE-2024-4548 CRITICAL POC
9.8 May 06

An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalcula

CVE-2024-4547 CRITICAL POC
9.8 May 06

A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalculat

CVE-2024-4549 HIGH POC
7.5 May 06

A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. Rated high severity (CV

CVE-2022-33005 MEDIUM POC
6.1 Jun 27

A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1

CVE-2026-78308 CRITICAL
9.8 Sep 24

Improper authentication in Delta Electronics DIAEnergie before 1.11.00.022 allows authentication bypass, enabling remote

CVE-2024-25574 CRITICAL
9.8 Apr 01

SQL injection vulnerability exists in GetDIAE_usListParameters. Rated critical severity (CVSS 9.8), this vulnerability i

CVE-2022-43775 CRITICAL
9.8 Oct 26

The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to ga

CVE-2022-43774 CRITICAL
9.8 Oct 26

The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacke

CVE-2022-3214 CRITICAL
9.8 Sep 16

Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-c

CVE-2022-1378 CRITICAL
9.8 May 02

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p

CVE-2022-1377 CRITICAL
9.8 May 02

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_r

CVE-2022-1376 CRITICAL
9.8 May 02

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy