Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessAuthenticate with low-privilege DIAEnergie account
-
DeliveryIdentify request with user-controlled key/ID
-
ExploitTamper ID to reference unauthorized object
-
ExecutionServer skips ownership check
-
ImpactRead other users' sensitive data
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Object-level authorization, IDOR prevention
|
| Exploitation Conditions | Requires a valid authenticated session to DIAEnergie at low privilege (PR:L) - this is NOT unauthenticated. Exploitation then depends on an application function that accepts a user-controlled key/identifier (record ID, report ID, or object reference) and fails to verify the requesting user's authorization for that object. No user interaction by a victim is needed (UI:N), and it is network-reachable (AV:N) against the DIAEnergie web/API interface. The main limiting factor is the credential requirement, confining realistic abuse to legitimate low-privilege users, malicious insiders, or attackers who have already obtained credentials; impact is bounded to unauthorized data disclosure (C:L) with no integrity or availability effect. |
| Impact | This is a genuine but low-priority issue, not a high-CVSS scare. The vendor CVSS 3.1 base of 4.3 (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N) is internally consistent with CWE-639 (Authorization Bypass Through User-Controlled Key, i.e. IDOR/BOLA): a network-reachable, low-complexity flaw exploitable by an already-authenticated low-privilege user, yielding only limited confidentiality impact with no integrity or availability effect. All exploitation signals point AWAY from urgency: no EPSS score is provided, the CVE is NOT in CISA KEV, and no public POC is referenced - exploitation status is therefore 'no public exploit identified at time of analysis.' There is no SSVC data supplied. The single limiting factor that most constrains real risk is PR:L: an attacker must first hold valid low-privilege credentials to the DIAEnergie application, so this is a horizontal/vertical data-access-broadening flaw for insiders or post-compromise actors rather than a pre-auth internet worm. No data conflicts are present; the description and CVSS vector agree. Note the CVE is self-reported by the vendor (Deltaww) via a single advisory PDF with no independent NVD enrichment, so severity rests solely on vendor assertion. |
| Exploit ScenarioDerived | An authenticated low-privilege DIAEnergie user modifies a user-controlled identifier (such as a record, report, or object ID) in an API or web request to reference data belonging to another user or tenant that they are not authorized to view, and the application returns it without an ownership check. No public exploit code is referenced, and exploitation requires valid application credentials first. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Sep 24, 2026
An authorization bypass through a user-controlled key (CWE-639) exists in Delta Electronics DIAEnergie versions before 1.11.00.022, allowing a low-privilege authenticated user to reference objects or records belonging to other users and read data they are not authorized to access. The flaw is network-reachable (AV:N) and requires no victim interaction (UI:N), but exploitation is gated behind a valid low-privilege session (PR:L), so realistic abuse is limited to malicious insiders, legitimate users exceeding their privileges, or attackers who have already obtained credentials; impact is bounded to confidentiality (C:L) with no integrity or availability effect, giving a CVSS 3.1 base score of 4.3. No public exploit code has been identified at time of analysis and the issue is not confirmed actively exploited (CISA KEV), making this a genuine but low-priority weakness rather than a high-severity emergency.
RemediationAI
Upgrade DIAEnergie to version 1.11.00.022 or later, which is the vendor-released fix identified for this and the related CVE-2026-78308 through CVE-2026-78313 issues; consult the Delta advisory PCSA-2026-00014 at https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00014_DIAEnergie%20Multiple%20Vulberabilities%20(CVE-2026-78308%20~%2078313).pdf for the complete patching instructions and any sequencing guidance. Where immediate upgrading is not possible, apply compensating controls that address the object-level authorization gap rather than relying on generic defense in depth: restrict network reachability of the DIAEnergie web/API interface to trusted management VLANs or a VPN jump host (side effect: adds latency and may complicate remote reporting workflows), audit and reduce the number of low-privilege accounts that can reach object-returning endpoints (side effect: role consolidation can increase per-account blast radius if those credentials leak), terminate idle sessions aggressively and enforce MFA on all DIAEnergie logins to make credential-based exploitation harder (side effect: operational friction for shift and field staff), and enable and review access logs on DIAEnergie API calls for sequential or cross-tenant identifier enumeration, which may indicate IDOR probing (side effect: log volume and the need for tuning). Note that because authorization is enforced only at the object level in the vulnerable code, web application firewalls and generic input validation are unlikely to fully mitigate the flaw and should be treated as detection aids, not fixes.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
CWE-639 (Authorization Bypass Through User-Controlled Key) is the classic insecure direct object reference (IDOR) pattern: an application endpoint accepts a client-supplied identifier - a record ID, report ID, meter or tag reference, or similar object key - and returns the associated resource without verifying that the requesting principal is entitled to that object. In DIAEnergie, Delta's industrial energy management / SCADA-adjacent platform, such endpoints are exposed through the web/API interface, which is why the vector is AV:N with AC:L. Because the request is made with a valid low-privilege account (PR:L), the platform's authentication layer is satisfied and the missing piece is purely object-level authorization; no victim user needs to click or interact (UI:N). The CPE cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:* confirms the affected scope is the DIAEnergie application across the version range below 1.11.00.022 rather than a specific module, and the CVE is part of a coordinated Delta advisory batch (PCSA-2026-00014) covering CVE-2026-78308 through CVE-2026-78313, indicating a broader hardening pass on the product's authorization and input handling. Practical consequence is enumeration and disclosure of data belonging to other tenants, sites, or higher-privileged roles - in an industrial energy context that can mean meter readings, configuration details, or operational metadata - but the absent integrity and availability components mean the bug cannot by itself alter or disrupt energy-management data.
Know when Diaenergie gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
Network-reachable IDOR requiring authenticated low-privilege access (PR:L), no user interaction, yielding only limited data disclosure (C:L) with no integrity/availability impact.
Primary rating from Vendor (Deltaww).
CVSS VectorVendor: Deltaww
Lifecycle Timeline
1DescriptionCVE.org
Authorization Bypass Through User-Controlled Key in DIAEnergie.
This issue affects DIAEnergie: before 1.11.00.022.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
More in Diaenergie
View allAn SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalcula
A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalculat
A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. Rated high severity (CV
A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1
Improper authentication in Delta Electronics DIAEnergie before 1.11.00.022 allows authentication bypass, enabling remote
SQL injection vulnerability exists in GetDIAE_usListParameters. Rated critical severity (CVSS 9.8), this vulnerability i
The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to ga
The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacke
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-c
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_r
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p
EUVD-2026-85821
GHSA-854f-fmg9-6cvm
NVD
CVE.org
EPSS
Vulnrichment
VulDB
Exploit-DB