Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessObtain low-privileged DIAEnergie account
-
DeliverySend crafted HTTP request with SQL payload
-
ExploitInject SQL into vulnerable query parameter
-
ExecutionInvoke OS command execution via database engine
-
ImpactExecute arbitrary code on host system
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Parameterized queries, prepared statements
MITRE ATT&CK
2 techniques across 2 tactics: Initial Access, Persistence The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires a valid low-privileged user account on the DIAEnergie platform - confirmed by CVSS PR:L; unauthenticated exploitation is not supported by the available vector. The attack is network-accessible (AV:N) with no user interaction (UI:N) and low complexity (AC:L), meaning no special environmental configuration beyond holding a valid session is needed. The RCE escalation beyond SQL injection is conditioned on the database backend supporting OS command execution features such as SQL Server's xp_cmdshell; if this feature is disabled at the database tier, exploitation may be limited to unauthorized data read/write rather than full OS-level code execution. Exploitation is bounded to DIAEnergie versions at or below v1.11.00.002; the scope metric S:U indicates no inherent lateral scope change within the base exploit chain. |
| Impact | The CVSS 3.1 score of 8.8 (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) reflects a network-accessible flaw with low attack complexity and low privilege requirements, yielding full confidentiality, integrity, and availability impact via confirmed RCE. The PR:L designation indicates some authenticated access is required - a meaningful but not prohibitive barrier in ICS environments where default, shared, or weakly managed credentials are prevalent. No EPSS score was provided in the available data, which is a gap that limits probabilistic exploitation modeling; this should be checked against current NVD or FIRST data. The CVE does not appear in CISA KEV and no public POC has been identified at time of analysis, suggesting exploitation has not yet been observed at scale. Despite this, the combination of network vector, low complexity, and RCE capability in an OT-adjacent energy management platform represents high operational risk: even organizations operating with limited security resources should treat this as a priority patch given the potential for disruption to energy monitoring and control functions. SSVC signals suggest the automatable dimension is likely yes - the network-reachable, low-complexity vector requires no environmental setup - and technical impact is total given OS-level code execution. |
| Exploit ScenarioDerived | An attacker with a low-privileged DIAEnergie user account sends a crafted HTTP request to the application, embedding SQL injection payloads in a vulnerable query parameter. The injected SQL manipulates the backend database to invoke OS-level command execution (e.g., via SQL Server xp_cmdshell), achieving remote code execution under the database service account's privileges. From this foothold, the attacker can exfiltrate energy management data, alter operational configurations, or pivot further into the OT network. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Aug 24, 2026
SQL injection in Delta DIAEnergie versions up to and including v1.11.00.002 enables authenticated network-accessible attackers to escalate from data manipulation to remote code execution on the underlying host. Confirmed by vendor advisory Delta PCSA-2026-00015 and EUVD-2026-64759, the vulnerability (CWE-89) carries a CVSS 3.1 score of 8.8, reflecting low attack complexity and full CIA impact. No public exploit or CISA KEV listing has been identified at time of analysis, but the RCE pathway in an energy management system warrants priority remediation.
RemediationAI
The primary remediation is to upgrade Delta DIAEnergie to a version above v1.11.00.002 per vendor advisory Delta PCSA-2026-00015 (https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00015_DIAEnergie%20SQL%20Injection%20Vulberabilities_v1.0.pdf); the exact fixed version number is not specified in available intelligence and must be confirmed directly from that advisory before deployment. If immediate patching is not feasible, compensating controls should include isolating the DIAEnergie interface behind a VPN or firewall to prevent access from untrusted network segments - this directly addresses the AV:N attack vector. At the database tier, disabling xp_cmdshell (or equivalent OS execution procedures) on the SQL Server backend will break the SQLi-to-RCE escalation pathway, limiting impact to data exposure rather than full system compromise, though this may affect DIAEnergie functionality and should be tested. Enforcing strong, unique credentials for all DIAEnergie accounts raises the bar against the PR:L condition. Generic network segmentation without specifically restricting the application port is insufficient - the restriction must target the DIAEnergie web service directly.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
Delta DIAEnergie (CPE: cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*) is an industrial energy management system (EMS) developed by Delta Electronics (Deltaww), used in building automation and industrial settings. The vulnerability is classified as CWE-89 (Improper Neutralization of Special Elements used in an SQL Command), meaning user-supplied input is incorporated into SQL queries without adequate sanitization or parameterization. In SQL Server environments - common for SCADA/ICS-adjacent applications - this class of flaw can be escalated to OS-level command execution via stored procedures such as xp_cmdshell, explaining the confirmed RCE capability. The CVSS vector AV:N confirms the vulnerable endpoint is reachable over the network, consistent with a web-based EMS interface.
Know when Diaenergie gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Network-accessible web interface with authenticated SQLi-to-RCE; PR:L because a valid account is required; full C/I/A reflects OS-level code execution capability.
Primary rating from Vendor (Deltaww).
CVSS VectorVendor: Deltaww
DescriptionCVE.org
SQL Injection in Delta DIAEnergie v1.11.00.002 allows attacker to remote code execution.
Executive ViewAI
Delta DIAEnergie versions through v1.11.00.002 contain a SQL injection vulnerability (CVE-2026-78314, CVSS 8.8) allowing authenticated users to achieve remote code execution on critical energy management systems. While no public exploit has been identified at time of analysis, the vulnerability poses significant organizational risk to operational continuity and data integrity. Immediate action to isolate and monitor affected systems is essential pending vendor patch availability.
No vendor-released patch identified at time of analysis. Interim mitigations include network access restriction and segmentation to minimize exposure surface, mandatory enforcement of authentication controls with periodic credential rotation, database-level monitoring and alerting on anomalous SQL patterns or unauthorized query execution, and network isolation to prevent lateral movement in event of compromise. Maintain monitoring of Delta vendor advisories for patch announcement and pre-stage deployment procedures to enable rapid remediation when available.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
SQL injection exploits the way applications construct database queries by mixing user input directly into SQL statements.
Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.
More in Diaenergie
View allAn SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalcula
A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalculat
A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. Rated high severity (CV
A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1
Improper authentication in Delta Electronics DIAEnergie before 1.11.00.022 allows authentication bypass, enabling remote
SQL injection vulnerability exists in GetDIAE_usListParameters. Rated critical severity (CVSS 9.8), this vulnerability i
The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to ga
The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacke
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-c
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_r
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p
EUVD-2026-64759
GHSA-67rf-2m7v-g5q7
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB