Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Network-accessible web interface with authenticated SQLi-to-RCE; PR:L because a valid account is required; full C/I/A reflects OS-level code execution capability.
Primary rating from Vendor (Deltaww).
CVSS VectorVendor: Deltaww
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
2DescriptionCVE.org
SQL Injection in Delta DIAEnergie v1.11.00.002 allows attacker to remote code execution.
AnalysisAI
SQL injection in Delta DIAEnergie versions up to and including v1.11.00.002 enables authenticated network-accessible attackers to escalate from data manipulation to remote code execution on the underlying host. Confirmed by vendor advisory Delta PCSA-2026-00015 and EUVD-2026-64759, the vulnerability (CWE-89) carries a CVSS 3.1 score of 8.8, reflecting low attack complexity and full CIA impact. …
Unlock full vulnerability intelligence
- Risk assessment & exploitation conditions
- Attack chain visualization
- Remediation with exact patch versions
- Threat intelligence from 22 sources
- Personal watchlist & email alerts
Free forever · No credit card required
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata
Vulnerability AssessmentAI
| Exploitation | Exploitation requires a valid low-privileged user account on the DIAEnergie platform - confirmed by CVSS PR:L; unauthenticated exploitation is not supported by the available vector. … Additional conditions and limiting factors are described in the full assessment. |
| Risk Assessment | The CVSS 3.1 score of 8.8 (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) reflects a network-accessible flaw with low attack complexity and low privilege requirements, yielding full confidentiality, integrity, and availability impact via confirmed RCE. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in. |
| Exploit Scenario | An attacker with a low-privileged DIAEnergie user account sends a crafted HTTP request to the application, embedding SQL injection payloads in a vulnerable query parameter. The injected SQL manipulates the backend database to invoke OS-level command execution (e.g., via SQL Server xp_cmdshell), achieving remote code execution under the database service account's privileges. … |
| Remediation | The primary remediation is to upgrade Delta DIAEnergie to a version above v1.11.00.002 per vendor advisory Delta PCSA-2026-00015 (https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00015_DIAEnergie%20SQL%20Injection%20Vulberabilities_v1.0.pdf); the exact fixed version number is not specified in available intelligence and must be confirmed directly from that advisory before deployment. … Detailed patch versions, workarounds, and compensating controls in full report. |
Recommended ActionAI
Within 24 hours, identify and document all Delta DIAEnergie installations with current version status, and restrict network access to these systems to essential authorized personnel only. …
Sign in for detailed remediation steps and compensating controls.
Threat intelligence, references, and detailed analysis are available after sign-in.
More in Diaenergie
View allAn SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalcula
A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalculat
A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. Rated high severity (CV
A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1
SQL injection vulnerability exists in GetDIAE_usListParameters. Rated critical severity (CVSS 9.8), this vulnerability i
The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to ga
The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacke
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-c
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_r
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_s
Same weakness CWE-89 – SQL Injection
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2026-64759
GHSA-67rf-2m7v-g5q7