Skip to main content

Infrasuite Device Master CVE-2023-1133

CRITICAL
Deserialization of Untrusted Data (CWE-502)
2023-03-27 ics-cert@hq.dhs.gov
9.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A08:2025 - Software or Data Integrity Failures
ASVS 5.0
V1 - Encoding and Sanitization Safe deserialization, type allowlists
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Initial Access

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available.

Exploit ScenarioDerived

A remote attacker could execute arbitrary code through malicious serialized objects by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability.

Emergency Immediate action required. Why: CRITICAL + EPSS > 30%, no patch available.
No patch listed yet 50.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid deserializing untrusted data. Use safe serialization formats (JSON). Implement integrity checks and type allowlists.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Deserialization of Untrusted Data (CWE-502), which allows attackers to execute arbitrary code through malicious serialized objects. Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated attacker to remotely execute arbitrary code. Affected products include: Deltaww Infrasuite Device Master. Version information: prior to 1.0.5.

Know when Infrasuite Device Master gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionNVD

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated attacker to remotely execute arbitrary code.

Threat Intelligence Overview

EPSS Score
50.0%
Top 1% exploitable
Exploit
POC
Public exploit code exists
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC Yes
EPSS 50.0%
Patch available No
Active threat Yes
Deciding rule
CRITICAL + EPSS > 30%, no patch available
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Immediate
Exploitation· derived
Active
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
High

Priority Score

134
Low Medium High Critical
KEV: 0
EPSS: +50
CVSS: +49
PoC: +20
Weaponized: +15
Threat intel: 0
Gov advisory: 0

Attack Technique

Insecure deserialization occurs when an application converts serialized data (a stream of bytes representing an object's state) back into a living object without proper validation.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

Affected Products (CPE)NVD

cpe:2.3:a:deltaww:infrasuite_device_master:*:*:*:*:*:*:*:*
CVE-2023-47207 CRITICAL
9.8 Nov 30

In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to

CVE-2023-39226 CRITICAL
9.8 Nov 30

In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to

CVE-2023-30765 CRITICAL
9.8 Jul 10

​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an

CVE-2023-34347 CRITICAL
9.8 Jul 10

​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which

CVE-2023-1142 CRITICAL
9.8 Mar 27

In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve sy

CVE-2023-1140 CRITICAL
9.8 Mar 27

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker

CVE-2022-41779 CRITICAL
9.8 Oct 31

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verif

CVE-2022-41772 CRITICAL
9.8 Oct 31

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters us

CVE-2022-41657 CRITICAL
9.8 Oct 31

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized

CVE-2022-40202 CRITICAL
9.8 Oct 31

The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper aut

CVE-2022-38142 CRITICAL
9.8 Oct 31

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through

CVE-2022-41629 CRITICAL
9.1 Oct 31

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunn

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy