Infrasuite Device Master
CVE-2022-41657
CRITICAL
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.
AnalysisAI
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Path Traversal vulnerability could allow attackers to access files and directories outside the intended path.
Technical ContextAI
This vulnerability is classified as Path Traversal (CWE-22), which allows attackers to access files and directories outside the intended path. Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution. Affected products include: Deltaww Infrasuite Device Master.
RemediationAI
A vendor patch is available. Apply the latest security update as soon as possible. Validate and canonicalize file paths. Use chroot or sandboxing. Reject input containing path separators or '../' sequences.
More in Infrasuite Device Master
View allDelta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status se
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to
Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an
Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve sy
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verif
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters us
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper aut
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunn
Same weakness CWE-22 – Path Traversal
View allShare
External POC / Exploit Code
Leaving vuln.today