Lantronix SLC8000 EUVDEUVD-2026-84512

| CVE-2026-80147 CRITICAL
Stack-based Buffer Overflow (CWE-121)
2026-09-22 VulnCheck GHSA-gqp9-cvw4-f6q4
9.4
CVSS 4.0 · Vendor: VulnCheck
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Reach terminal/CLI management interface
  2. Delivery
    Authenticate as any low-privilege user
  3. Exploit
    Invoke undocumented mfc eeprom write command
  4. Execution
    Supply oversized input overflowing stack buffer
  5. Persist
    Hijack control into system() call
  6. Impact
    Execute arbitrary code, pivot to serial-attached devices

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Stack buffer bounds checking
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires the attacker to authenticate as any user (including low-privilege) to the device's terminal or CLI management interface, then invoke the undocumented 'mfc eeprom write' command with input larger than the fixed stack buffer. Limiting factors: authentication is required (PR:L), so exposure hinges on the management interface being network-reachable and on credential strength; the command is undocumented, so the attacker must know it exists (the revrb.net and VulnCheck write-ups now disclose it). Affected: SLC8000 before 9.7.0.2, EMG8500/EMG7500 before 9.7.0.1, and all firmware of SLB882/SLCx-03/SLCx-02 (no patch exists for the latter three). Successful exploitation impacts both the device and downstream serial-attached equipment.

Impact

This is a genuine high-priority issue where nearly all signals align toward serious risk. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N with VC:H/VI:H/VA:H and subsequent-system SC:H/SI:H/SA:H) describes low-complexity, network-reachable, authenticated code execution that also compromises downstream serial-attached systems - earning a well-founded 9.4. CWE-121 stack overflow flowing into a system() call is a classic reliable-RCE primitive, and a patch is available from Lantronix, all of which raise the credibility of the technical severity. Countervailing signals temper the urgency: EPSS is not provided, there is no CISA KEV listing, and no public POC is referenced (only a VulnCheck advisory and a revrb.net write-up), so there is no evidence of active or automated exploitation - this reads as a serious-but-not-yet-weaponized flaw. The main limiter is PR:L: an attacker must first authenticate to the terminal or CLI, so exposure depends heavily on whether the management interface is network-reachable and how credential hygiene is managed. Note the SC/SI/SA:H subsequent-system impact is the reason my independent CVSS 3.1 mapping uses scope-change (S:C), yielding ~9.9. A caveat for defenders: SLB882, SLCx-03, and SLCx-02 have NO fix across all firmware versions, so for those models this remains an unpatchable exposure requiring compensating controls.

Exploit ScenarioDerived

An attacker who can reach the console-server's terminal or CLI management interface authenticates as any user (even a low-privilege account) and invokes the undocumented 'mfc eeprom write' command with an oversized argument, overflowing a bounded stack buffer that is subsequently passed to system(). This yields arbitrary code execution on the device and can cascade to the serial-attached equipment it manages. No public exploit code is identified at time of analysis, but a VulnCheck advisory and a revrb.net technical write-up describe the mechanism in detail.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
Patch available 0.8% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Sep 22, 2026

An authenticated stack-based buffer overflow in Lantronix SLC8000, EMG8500/EMG7500, SLB882 and SLCx-02/SLCx-03 console management devices lets a user who can reach the terminal or CLI interface invoke an undocumented 'mfc eeprom write' command and supply oversized input that overflows a fixed stack buffer before the data is handed to a system() call, potentially yielding arbitrary code execution with full loss of confidentiality, integrity and availability on the device and on serial-attached downstream equipment. The flaw is scored 9.4 (CVSS 4.0, PR:L, scope-changed downstream impact) and requires authentication as any user, including low-privilege accounts, so exposure depends on whether the management interface is network-reachable and on credential strength. Vendor firmware fixes are available for SLC8000 (9.7.0.2), EMG8500 (9.7.0.1) and EMG7500 (9.7.0.1); no public exploit code was identified at time of analysis, though the undocumented command has now been publicly documented by VulnCheck and revrb.net, and SLB882/SLCx-03/SLCx-02 have no vendor patch.

RemediationAI

Apply the vendor firmware fixes: upgrade SLC8000 to firmware v9.7.0.2 (package 9.7.0.2R1 at https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/) and upgrade EMG8500 and EMG7500 to firmware v9.7.0.1 (packages 9.7.0.1R2 at https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ and https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/), per the VulnCheck advisory at https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-write. For SLB882, SLCx-03 and SLCx-02 no vendor-released patch was identified at time of analysis, so compensating controls are required: restrict the terminal/CLI management interface to a dedicated, tightly firewalled management VLAN or bastion jump host rather than exposing it to general networks (trade-off: administrators lose direct remote CLI access and must route through the jump host, adding latency and a single point of failure); disable unused management services such as telnet and unencrypted HTTP in favour of SSH/HTTPS where the platform allows (trade-off: some legacy management tooling may depend on those protocols); enforce strong, unique credentials and least-privilege accounts, since exploitation requires only any authenticated user including low-privilege ones, and rotate credentials that may have been shared (trade-off: credential rotation and vaulting add operational overhead); and monitor CLI sessions and logs for use of the undocumented 'mfc eeprom write' command or unexpectedly long command arguments as a detection signal for attempted exploitation, while segmenting and auditing serial-attached downstream devices in case the appliance itself is compromised.

Affected VersionsENISA

SLB882 *
SLCx-02 *
EMG7500 0 <9.7.0.1
EMG8500 0 <9.7.0.1
SLC8000 0 <9.7.0.2
SLCx-03 *

Affected Packages

euvd emg7500 fix: 9.7.0.1
euvd emg8500 fix: 9.7.0.1
euvd slc8000 fix: 9.7.0.2

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 3 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The root cause is CWE-121, a stack-based buffer overflow, in the CLI/terminal command parser of Lantronix out-of-band and serial console management appliances. The undocumented 'mfc eeprom write' command copies an attacker-supplied argument into a fixed-size stack buffer without bounds checking, and the resulting buffer content is subsequently passed to a system() call - combining a classic overflow with command-execution primitives in the same code path. Because the affected devices are deployed as out-of-band management gateways, they commonly sit on dedicated management networks and hold serial or console links to routers, switches, servers and other infrastructure; that architecture is why the CVSS 4.0 vector (CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H) and the independent CVSS 3.1 assessment (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H) both capture subsequent-system impact beyond the appliance itself. The PR:L metric confirms the attacker must already hold credentials for the terminal or CLI interface, and the attack is delivered over the network to a reachable management interface; the 'mfc eeprom write' command is undocumented, so successful exploitation presumes the attacker knows the command name, which the revrb.net and VulnCheck write-ups now publicly disclose.

Know when Slc8000 gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (VulnCheck) PRIMARY 9.4 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
vuln.today AI 9.9 CRITICAL

Network-reachable CLI with low-privilege auth (PR:L, AC:L); scope change (S:C) because code execution cascades to downstream serial-attached devices, giving full C/I/A impact.

3.1 AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Primary rating from Vendor (VulnCheck).

CVSS VectorVendor: VulnCheck

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
High
Subsequent system: Integrity
High
Subsequent system: Availability
High

DescriptionCVE.org

Lantronix SLC8000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.

Executive ViewAI

Why It Matters

Lantronix SLC8000, EMG8500/EMG7500, SLB882 and SLCx-02/SLCx-03 console management devices contain a critical authenticated buffer overflow that can let a low-privilege user with CLI access run arbitrary code, causing full loss of confidentiality, integrity, and availability on the device and on serial-attached downstream equipment. Leadership should prioritize this because these consoles often provide out-of-band or OT access, so a compromise can cascade into connected infrastructure. Vendor patches are available for SLC8000, EMG8500, and EMG7500, and no public exploit identified at time of analysis.

Business Impact: Severe
Compensating Controls

Apply vendor patch. For SLB882 and SLCx-02/SLCx-03 with no exact fix version listed, restrict CLI and network access, enforce strong unique credentials, segment management interfaces, and monitor for 'mfc eeprom write' abuse.

Threat Intelligence Overview

EPSS Score
0.8%
Top 45% exploitable
Prevalence
Low
niche out-of-band console servers for industrial and datacenter infrastructure
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 0.8%
Patch available Yes
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact
Very High
Technical Impact
Total

Priority Score

48
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +47
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

CVE-2026-80155 CRITICAL
10.0 Sep 22

Unauthenticated remote attackers can completely compromise the web management portal of Lantronix console servers, readi

CVE-2026-80144 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix out-of-band console managers (SLC8000, EMG8500/EMG7500, SLB882, SLCx-03, SL

CVE-2026-80143 CRITICAL
9.4 Sep 22

Authenticated OS command injection in Lantronix out-of-band management appliances (SLC8000, EMG8500, EMG7500, SLB882, SL

CVE-2026-80152 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix SLC8000 console servers (before firmware v9.7.0.3), EMG8500/EMG7500 (before

CVE-2026-80151 CRITICAL
9.4 Sep 22

Root-level command injection in Lantronix console servers - SLC8000, EMG8500, EMG7500, SLB882, SLCx-03 and SLCx-02 - let

CVE-2026-80145 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix console/out-of-band management appliances (SLC8000, EMG8500, EMG7500, SLB88

CVE-2026-80156 CRITICAL
9.4 Sep 22

Authenticated file-write path traversal in the Lantronix web management portal lets a logged-in attacker upload a crafte

CVE-2026-80146 CRITICAL
9.4 Sep 22

Authenticated remote code execution in Lantronix SLC8000, EMG8500/EMG7500, SLB882, SLCx-03, and SLCx-02 console servers

CVE-2026-80154 HIGH
8.9 Sep 22

Predictable session-token generation in the web management portal of Lantronix SLC8000, EMG8500, EMG7500, SLB882, SLCx-0

CVE-2026-80150 HIGH
7.7 Sep 22

Server-side request forgery in the WebSSH/WebTelnet listener of Lantronix SLC8000 (before firmware 9.7.0.3), EMG8500/EMG

CVE-2026-80149 HIGH
7.7 Sep 22

Unauthenticated server-side request forgery in the Lantronix SLC8000, EMG8500/EMG7500 and SLB882 console servers lets an

CVE-2026-80148 HIGH
7.7 Sep 22

Unauthenticated server-side request forgery in the WebSSH/WebTelnet web terminal listener of Lantronix SLC8000 console s

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy