Skip to main content

Lantronix SLC8000 CVE-2026-80156

| EUVDEUVD-2026-84523 CRITICAL
Path Traversal (CWE-22)
2026-09-22 VulnCheck GHSA-hmch-26g2-q5qx
9.4
CVSS 4.0 · Vendor: VulnCheck
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Obtain authenticated portal access
  2. Delivery
    Craft filename with backslash+forward-slash
  3. Exploit
    Bypass upload path validation
  4. Execution
    Write file outside upload dir
  5. Persist
    Execute code on device
  6. Impact
    Pivot to serial-connected devices

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V5 - File Handling Path canonicalization, traversal prevention
MITRE ATT&CK

2 techniques across 2 tactics: Discovery, Collection

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Requires an authenticated session on the Lantronix web management portal (PR:H) reachable over the network; the specific trigger is the upload endpoint's filename validation, which strips backslash characters but then fails to check for forward slashes, so a filename containing BOTH characters escapes the intended upload directory and writes to any writable filesystem path. No user interaction is needed beyond the attacker's own authenticated request. Limiting factors: management portal must be network-accessible to the attacker and valid credentials (or credential compromise) are required - devices with the portal restricted to isolated management networks and strong admin credentials are substantially less exposed. Affected: SLC8000 before v9.7.0.5, EMG8500/EMG7500 before v9.7.0.1, and all firmware of SLB882/SLCx-03/SLCx-02 (no listed fix).

Impact

This is a genuine high-priority issue, not a high-CVSS-but-low-risk artifact. The vendor CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:H/UI:N with full VC:H/VI:H/VA:H and subsequent-system SC:H/SI:H/SA:H, score 9.4) describes a network-reachable, low-complexity path-traversal-to-arbitrary-file-write that yields RCE on out-of-band console servers - devices that by design manage other equipment, so the SC/SI/SA:H (downstream serial-connected devices) is credible rather than inflated. The one real gate is PR:H: exploitation requires an authenticated session on the web management portal, which meaningfully lowers mass-exploitation likelihood versus an unauthenticated flaw. No EPSS score, no CISA KEV listing, and no explicitly-flagged public exploit code are provided, so current status is 'no public exploit identified at time of analysis' - however, two detailed technical writeups (VulnCheck advisory and the revrb.net 'revrb-lantern' post) publicly document the exact validation-bypass mechanism (backslash stripping without a subsequent forward-slash check), which substantially lowers the barrier to weaponization even though no packaged PoC is confirmed. Net: elevated risk for exposed/administratively-accessible Lantronix OOB devices, tempered by the authentication requirement and absence of confirmed in-the-wild use.

Exploit ScenarioDerived

An attacker who has (or has obtained via weak/default/reused credentials) an authenticated session to the Lantronix web management portal submits an upload whose filename contains both a backslash and a forward slash; the validation strips the backslash but fails to re-check for the forward slash, letting the file be written outside the intended directory to any writable path, which is then leveraged for code execution. Public technical advisories from VulnCheck and revrb.net document the precise bypass, so reliable exploit development is straightforward even though no turnkey PoC is confirmed. Because these are out-of-band console servers, successful RCE can pivot to the serial-connected downstream infrastructure they manage.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
Patch available 1.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Sep 22, 2026

Authenticated file-write path traversal in the Lantronix web management portal lets a logged-in attacker upload a crafted filename that escapes the intended upload directory and writes arbitrary files to any writable location on the device, a primitive that can be leveraged for remote code execution and results in complete loss of confidentiality, integrity, and availability on the console server. Affected are SLC8000 units below firmware v9.7.0.5, EMG8500/EMG7500 below firmware v9.7.0.1, and all firmware versions of SLB882, SLCx-03, and SLCx-02 (no vendor fix published for those three models). Exploitation requires a valid authenticated session on the network-reachable management portal (CVSS v4.0 PR:H, AV:N), so exposure is highest where the portal is internet-facing or reachable from untrusted segments; there is no public exploit identified at time of analysis and the issue is not listed on CISA KEV, but the assessed impact and the embedded out-of-band role of these devices justify treating it as high priority.

RemediationAI

Vendor-released patch: upgrade SLC8000 to firmware 9.7.0.5R2 (or later) from https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/ and EMG8500/EMG7500 to firmware 9.7.0.1R2 from https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ and https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ respectively. For SLB882, SLCx-03, and SLCx-02 no vendor-released patch is identified at time of analysis, so those units require compensating controls: remove the management portal from untrusted networks by placing it on an isolated management VLAN or behind a jump host/VPN with ACLs limiting access to known administrators (trade-off: adds operational friction for remote console access but removes the network-reachable attack surface this flaw depends on), disable or restrict the web upload functionality if the appliance's configuration permits it (trade-off: may break firmware/configuration file deployment workflows), and enforce unique, strong administrator credentials with rotation since a valid session is the sole prerequisite (trade-off: none beyond credential management overhead). Where uploads cannot be disabled, monitor the filesystem and web access logs for unexpected files written outside the normal upload directory or for filenames containing mixed backslash and forward-slash sequences, and review serial-attached downstream devices for signs of lateral abuse given the out-of-band position of these appliances.

Affected VersionsENISA

EMG7500 0 <9.7.0.1
SLCx-03 *
SLCx-02 *
SLC8000 0 <9.7.0.5
SLB882 *
EMG8500 0 <9.7.0.1

Affected Packages

euvd emg7500 fix: 9.7.0.1
euvd emg8500 fix: 9.7.0.1
euvd slc8000 fix: 9.7.0.5

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 3 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The root cause is a classic path-traversal logic error (CWE-22) inside the filename-sanitization routine of the web management portal's file-upload endpoint on Lantronix out-of-band and serial console management appliances. The validation code detects a backslash in the supplied filename and strips it, but because a backslash was seen it skips the subsequent check for forward slashes; a filename that contains both a backslash and forward-slash sequences therefore survives sanitization and is used to build the write path, allowing traversal out of the designated upload directory. These appliances are embedded systems with a writable filesystem that hosts the web management stack and configuration, so arbitrary-file-write becomes remote code execution by dropping or overwriting scripts, binaries, or startup configuration in an executed path. The faulted devices are branch-office/out-of-band management products (CPE entries: lantronix:slc8000, lantronix:emg8500, lantronix:emg7500, lantronix:slb882, lantronix:slcx-03, lantronix:slcx-02), and because they sit in front of serial-managed network gear, compromise of the appliance can extend to downstream serial-connected equipment. The vendor advisory and an independent write-up (VulnCheck, revrb.net) document the flaw; the supplied CVSS v4.0 vector reports PR:H, consistent with a valid management session being required.

Know when Slc8000 gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (VulnCheck) PRIMARY 9.4 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
vuln.today AI 9.1 CRITICAL

Network-reachable authenticated portal (PR:H) with low-complexity filename bypass yielding full device RCE; S:C because compromise reaches downstream serial-connected devices.

3.1 AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Primary rating from Vendor (VulnCheck).

CVSS VectorVendor: VulnCheck

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
High
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
High
Subsequent system: Integrity
High
Subsequent system: Availability
High

DescriptionCVE.org

Lantronix SLC8000 before firmware v9.7.0.5, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a path traversal vulnerability in the web management portal upload endpoint that allows authenticated attackers to write arbitrary data to any location on the device's filesystem, leading to remote code execution. The upload filename validation strips backslash characters but does not subsequently check for forward slashes when a backslash is detected; by supplying a filename containing both characters an attacker writes outside the intended upload directory to any writable path. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.

Executive ViewAI

Why It Matters

Lantronix console servers, including SLC8000, EMG8500/EMG7500, SLB882, SLCx-03, and SLCx-02, are impacted by a critical authenticated file-write path traversal vulnerability (CVE-2026-80156) that can lead to remote code execution and full compromise of these out-of-band management devices. This poses a severe risk to organizations relying on these devices for secure remote access to critical network infrastructure, as a successful exploit could disrupt operations and grant attackers control over connected systems. Although there is no public exploit identified at time of analysis, the absence of a patch for several models and the high impact underscore the need for immediate leadership attention.

Business Impact: Severe
Compensating Controls

Apply vendor patch.

Threat Intelligence Overview

EPSS Score
1.0%
Top 38% exploitable
Prevalence
Low
Niche Lantronix out-of-band console/terminal servers, industrial/IT-infrastructure deployments only
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 1.0%
Patch available Yes
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact
Very High
Technical Impact
Total

Priority Score

48
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +47
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Path traversal exploits occur when applications use user-controlled input to construct file system paths without proper validation.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

CVE-2026-80155 CRITICAL
10.0 Sep 22

Unauthenticated remote attackers can completely compromise the web management portal of Lantronix console servers, readi

CVE-2026-80144 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix out-of-band console managers (SLC8000, EMG8500/EMG7500, SLB882, SLCx-03, SL

CVE-2026-80143 CRITICAL
9.4 Sep 22

Authenticated OS command injection in Lantronix out-of-band management appliances (SLC8000, EMG8500, EMG7500, SLB882, SL

CVE-2026-80152 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix SLC8000 console servers (before firmware v9.7.0.3), EMG8500/EMG7500 (before

CVE-2026-80151 CRITICAL
9.4 Sep 22

Root-level command injection in Lantronix console servers - SLC8000, EMG8500, EMG7500, SLB882, SLCx-03 and SLCx-02 - let

CVE-2026-80145 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix console/out-of-band management appliances (SLC8000, EMG8500, EMG7500, SLB88

CVE-2026-80147 CRITICAL
9.4 Sep 22

An authenticated stack-based buffer overflow in Lantronix SLC8000, EMG8500/EMG7500, SLB882 and SLCx-02/SLCx-03 console m

CVE-2026-80146 CRITICAL
9.4 Sep 22

Authenticated remote code execution in Lantronix SLC8000, EMG8500/EMG7500, SLB882, SLCx-03, and SLCx-02 console servers

CVE-2026-80154 HIGH
8.9 Sep 22

Predictable session-token generation in the web management portal of Lantronix SLC8000, EMG8500, EMG7500, SLB882, SLCx-0

CVE-2026-80150 HIGH
7.7 Sep 22

Server-side request forgery in the WebSSH/WebTelnet listener of Lantronix SLC8000 (before firmware 9.7.0.3), EMG8500/EMG

CVE-2026-80149 HIGH
7.7 Sep 22

Unauthenticated server-side request forgery in the Lantronix SLC8000, EMG8500/EMG7500 and SLB882 console servers lets an

CVE-2026-80148 HIGH
7.7 Sep 22

Unauthenticated server-side request forgery in the WebSSH/WebTelnet web terminal listener of Lantronix SLC8000 console s

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy