Skip to main content

Lantronix SLC8000 CVE-2026-80145

| EUVDEUVD-2026-84509 CRITICAL
OS Command Injection (CWE-78)
2026-09-22 VulnCheck GHSA-6665-q8xg-hw4c
9.4
CVSS 4.0 · Vendor: VulnCheck
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate to terminal/CLI with 'services' permission
  2. Delivery
    Issue `set cifs password` with shell metacharacters
  3. Exploit
    Unsanitized input reaches system() call
  4. Execution
    Execute arbitrary commands as root
  5. Impact
    Compromise device and pivot to serial-attached devices

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK

2 techniques across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Requires an authenticated account with the 'services' permission on the affected Lantronix device, reachable via the terminal or CLI management interface; the attacker then supplies shell metacharacters through the set cifs password command parameter. Limiting factors: the 'services' privilege (PR:H) is not a default low-privilege role, exploitation is confined to whoever can reach the management CLI (best practice keeps this on a segmented management network), and the fully-affected exposure applies to SLB882/SLCx-03/SLCx-02 (no patch) plus unpatched SLC8000 (<9.7.0.2) and EMG8500/EMG7500 (<9.7.0.1). No user interaction beyond the attacker's own CLI session is needed.

Impact

The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:H/UI:N with full VC:H/VI:H/VA:H and subsequent-system SC:H/SI:H/SA:H) rates this 9.4 Critical, driven by root-level shell execution and cascading impact onto downstream serial-attached devices. However, PR:H is the decisive limiter: exploitation requires an authenticated account holding the specific 'services' permission, so this is a privilege-escalation/lateral-movement primitive for an already-trusted operator rather than an internet-facing pre-auth RCE. No EPSS score, KEV listing, or POC is present in the provided intelligence, so there is no signal of active or automated exploitation - this is a 'high-CVSS, real-but-gated' issue rather than a mass-exploitation emergency. The signals are internally consistent (network-reachable management CLI, low complexity once authenticated), but the practical risk hinges entirely on how tightly the 'services' role and management-plane network access are controlled. Note the incomplete patch story: SLB882, SLCx-03, and SLCx-02 have NO fix across all firmware versions, which elevates residual risk for those specific models.

Exploit ScenarioDerived

An attacker who has obtained (or been legitimately granted) a Lantronix account with the 'services' permission logs into the device's terminal or CLI interface and issues the set cifs password command with a crafted value containing shell metacharacters (e.g., a password embedding ; or $(...)). The unsanitized parameter is passed to a system() call, executing the injected commands as root, yielding full device compromise and a pivot toward downstream serial-attached equipment. No public exploit code is identified at time of analysis, but the technique is trivial once the required authenticated CLI access is held.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
Patch available 2.5% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Sep 22, 2026

Authenticated command injection in Lantronix console/out-of-band management appliances (SLC8000, EMG8500, EMG7500, SLB882, SLCx-03, SLCx-02) lets an attacker who already holds the 'services' permission reach the terminal or CLI interface and run arbitrary shell commands as root via a crafted set cifs password argument, resulting in complete loss of confidentiality, integrity and availability on the device and possible cascading impact on serial-attached downstream equipment. CVSS 4.0 rates this 9.4 (Critical) on an AV:N/AC:L/PR:H/UI:N vector with full VC:H/VI:H/VA:H and subsequent-system SC:H/SI:H/SA:H, and our independent CVSS 3.1 assessment (AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H) agrees on severity. The vendor has shipped patched firmware for SLC8000 (9.7.0.2) and for EMG8500/EMG7500 (9.7.0.1), while SLB882, SLCx-03 and SLCx-02 have no fix identified in any firmware version; no public exploit code was identified at time of analysis, and CISA KEV does not list this issue.

RemediationAI

Vendor-released patch: upgrade Lantronix SLC8000 to firmware v9.7.0.2 (image 9.7.0.2R1 from https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/) and EMG8500/EMG7500 to firmware v9.7.0.1 (image 9.7.0.1R2 from https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ and https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/); for SLB882, SLCx-03 and SLCx-02, no vendor-released patch was identified at time of analysis, so those deployments must rely on compensating controls until a fix ships. Specific controls, with their trade-offs: (1) immediately audit and remove the 'services' permission from every account that does not strictly require it, since the privilege is the sole gate on exploitation - this may break automation or delegated console administration; (2) restrict management CLI and terminal access to a dedicated, segmented management VLAN or jump host with firewall ACLs so an attacker cannot reach the vulnerable interface from user or internet-facing networks - this requires network re-architecture and can complicate remote support if not paired with an out-of-band path; (3) disable or leave unconfigured CIFS/SMB-backed features and avoid issuing set cifs password on unpatched units, blocking the vulnerable command path at the cost of losing CIFS-based file/log export; (4) enable and forward authentication and CLI command logging to a SIEM, alerting on any use of set cifs password or shell metacharacters in parameters, which detects but does not prevent exploitation; and (5) for SLB882/SLCx-03/SLCx-02 specifically, treat the devices as untrusted, isolate their serial-attached downstream equipment with separate credentials and monitoring, and plan hardware replacement or vendor escalation since no firmware fix is available. Apply the vendor firmware updates first on internet- or broadly reachable units and validate that the fixed image is the one documented in the VulnCheck advisory (https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-set-cifs-password).

Affected VersionsENISA

SLC8000 0 <9.7.0.2
SLB882 *
EMG7500 0 <9.7.0.1
SLCx-03 *
SLCx-02 *
EMG8500 0 <9.7.0.1

Affected Packages

euvd emg7500 fix: 9.7.0.1
euvd emg8500 fix: 9.7.0.1
euvd slc8000 fix: 9.7.0.2

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 3 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The root cause is CWE-78 (Improper Neutralization of Special Elements used in an OS Command), the classic command-injection class: the appliance's CLI handler for the set cifs password command concatenates the user-supplied parameter into a command string that is handed to a C library system() call, so shell metacharacters embedded in the password argument are interpreted by the underlying shell rather than treated as opaque data. Because the CLI process runs with elevated privileges, the injected payload executes as root on the appliance's embedded Linux firmware, and the CPE data confirms the affected product families are the Lantronix SLC8000, EMG8500, EMG7500, SLB882, SLCx-03 and SLCx-02 out-of-band console/terminal servers (cpe:2.3:a:lantronix:*). These devices sit at the management edge of network infrastructure, proxying serial console sessions to routers, switches and OT gear, so root compromise of the console server itself yields a pivot to everything wired to its serial ports. The prerequisite is a legitimate account carrying the 'services' permission, which is an administrative/privileged role rather than a default low-privilege account (reflected as PR:H in both the CVSS 4.0 vector and our CVSS 3.1 reassessment) and the attacker must be able to reach the terminal or CLI management interface, typically exposed only on a management network.

Know when Slc8000 gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (VulnCheck) PRIMARY 9.4 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
vuln.today AI 9.1 CRITICAL

Network-reachable CLI with low complexity but PR:H for the required 'services' permission; S:C because root RCE reaches downstream serial-attached devices beyond the security scope, with full C/I/A loss.

3.1 AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Primary rating from Vendor (VulnCheck).

CVSS VectorVendor: VulnCheck

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
High
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
High
Subsequent system: Integrity
High
Subsequent system: Availability
High

DescriptionCVE.org

Lantronix SLC8000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set cifs password command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.

Executive ViewAI

Why It Matters

Lantronix console and out-of-band management appliances - SLC8000, EMG8500, EMG7500, SLB882, SLCx-03 and SLCx-02 - contain a critical authenticated command-injection flaw that grants root-level control of the device to anyone already holding the 'services' permission. Because these appliances are the trusted recovery and management path into serial-attached network, industrial and facility equipment, a compromised unit can be used to disable monitoring, alter configurations or cut off management access to the systems behind it. Leadership should treat this as an out-of-band continuity risk: remediation is available for only three of the six affected platforms, leaving the remaining models exposed for the foreseeable future.

Business Impact: High
Compensating Controls

Apply vendor patch where available - SLC8000 (firmware 9.7.0.2) and EMG8500/EMG7500 (firmware 9.7.0.1). For SLB882, SLCx-03 and SLCx-02 no vendor-released patch has been identified at time of analysis: interim mitigations are to restrict management-interface access to a dedicated management VLAN or hardened jump host, enforce least privilege and minimize the number of accounts holding the 'services' permission, rotate credentials and keys for those accounts, enable session logging and alerting on CLI/terminal activity, and segment serial-attached downstream equipment so it cannot be reached or reconfigured from a compromised appliance.

Threat Intelligence Overview

EPSS Score
2.5%
Top 16% exploitable
Prevalence
Low
niche embedded out-of-band console servers for industrial/datacenter serial management
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 2.5%
Patch available Yes
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

50
Low Medium High Critical
KEV: 0
EPSS: +3
CVSS: +47
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

CVE-2026-80155 CRITICAL
10.0 Sep 22

Unauthenticated remote attackers can completely compromise the web management portal of Lantronix console servers, readi

CVE-2026-80144 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix out-of-band console managers (SLC8000, EMG8500/EMG7500, SLB882, SLCx-03, SL

CVE-2026-80143 CRITICAL
9.4 Sep 22

Authenticated OS command injection in Lantronix out-of-band management appliances (SLC8000, EMG8500, EMG7500, SLB882, SL

CVE-2026-80152 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix SLC8000 console servers (before firmware v9.7.0.3), EMG8500/EMG7500 (before

CVE-2026-80151 CRITICAL
9.4 Sep 22

Root-level command injection in Lantronix console servers - SLC8000, EMG8500, EMG7500, SLB882, SLCx-03 and SLCx-02 - let

CVE-2026-80156 CRITICAL
9.4 Sep 22

Authenticated file-write path traversal in the Lantronix web management portal lets a logged-in attacker upload a crafte

CVE-2026-80147 CRITICAL
9.4 Sep 22

An authenticated stack-based buffer overflow in Lantronix SLC8000, EMG8500/EMG7500, SLB882 and SLCx-02/SLCx-03 console m

CVE-2026-80146 CRITICAL
9.4 Sep 22

Authenticated remote code execution in Lantronix SLC8000, EMG8500/EMG7500, SLB882, SLCx-03, and SLCx-02 console servers

CVE-2026-80154 HIGH
8.9 Sep 22

Predictable session-token generation in the web management portal of Lantronix SLC8000, EMG8500, EMG7500, SLB882, SLCx-0

CVE-2026-80150 HIGH
7.7 Sep 22

Server-side request forgery in the WebSSH/WebTelnet listener of Lantronix SLC8000 (before firmware 9.7.0.3), EMG8500/EMG

CVE-2026-80149 HIGH
7.7 Sep 22

Unauthenticated server-side request forgery in the Lantronix SLC8000, EMG8500/EMG7500 and SLB882 console servers lets an

CVE-2026-80148 HIGH
7.7 Sep 22

Unauthenticated server-side request forgery in the WebSSH/WebTelnet web terminal listener of Lantronix SLC8000 console s

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy