Skip to main content

Circutor SGE-PLC1000 EUVDEUVD-2025-200232

| CVE-2025-11784 HIGH
Stack-based Buffer Overflow (CWE-121)
2025-12-02 cve-coordination@incibe.es
8.5
CVSS 4.0 · Vendor: incibe
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Gain adjacent-network access to concentrator
  2. Delivery
    Authenticate with low-privilege credentials
  3. Exploit
    Send oversized 'meter' parameter to ShowMeterDatabase()
  4. Execution
    Overflow fixed stack buffer via sprintf()
  5. Persist
    Corrupt stack / crash device
  6. Impact
    Achieve code execution or DoS on grid gateway

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Stack buffer bounds checking
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires adjacent-network reach to the SGE-PLC1000/SGE-PLC50 management interface (AV:A - same LAN/OT segment, not internet-facing) plus low-privilege authenticated access (PR:L) to invoke the ShowMeterDatabase() function. The concrete trigger is supplying an excessively long value for the 'meter' parameter, which GetParameter(meter) passes unvalidated into a fixed-size stack buffer via sprintf(). Affected firmware is confirmed as v9.0.2 for both models. Limiting factors: the attacker must already be on the adjacent network and possess valid low-tier credentials, and no default-config unauthenticated remote path is indicated; this substantially narrows realistic exposure versus the raw base score.

Impact

This is a stack-based buffer overflow (CWE-121) in Circutor SGE-PLC1000/SGE-PLC50 smart-grid PLC concentrators reached through an unbounded sprintf() on the 'meter' parameter. The vendor CVSS 4.0 vector (AV:A/AC:L/AT:N/PR:L/UI:N, VC:H/VI:L/VA:H, subsequent SC:H/SI:L/SA:H, base 8.5) frames it as an adjacent-network, low-privilege attack with high confidentiality/availability impact and a scope change onto downstream systems - consistent with memory corruption on an embedded metering gateway. Countervailing signals lower the real-world urgency: EPSS is only 0.07% (22nd percentile), there is no CISA KEV listing, and no public proof-of-concept is referenced, so exploitation is neither observed nor demonstrated. The AV:A choice materially constrains reach - an attacker must already be on the adjacent (local/utility segment) network AND hold low-privilege credentials (PR:L), not the internet-wide unauthenticated posture a raw 8.5 might suggest. Net: a genuinely serious memory-safety flaw in a niche ICS/OT device, but current exploitation likelihood is low and access-gated; prioritize for utilities running these concentrators, not as a broad emergency.

Exploit ScenarioDerived

An attacker with low-privilege access on the same network segment as an SGE-PLC1000/SGE-PLC50 concentrator submits an over-long 'meter' value to the ShowMeterDatabase() handler, which copies it via sprintf() into a fixed-size stack buffer, overflowing it. This can crash the device (availability loss) or, with a tailored payload, corrupt the stack toward code execution on the OT gateway. No public exploit code is currently referenced, so this remains a theoretical-but-credible path.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv2 – Sep 26, 2026

Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 smart-grid PLC concentrators running firmware v9.0.2 allows an attacker to corrupt memory and potentially achieve code execution or a denial-of-service condition by supplying an excessively long 'meter' parameter that is copied into a fixed-size stack buffer via sprintf() inside the ShowMeterDatabase() function. Exploitation requires the attacker to already reside on the adjacent network (same LAN/OT segment) and to hold valid low-privilege credentials, since the parameter is reached through an authenticated management function; the CVE carries a base CVSS of 8.5, though our independent assessment (CVSS 3.1 AV:A/PR:L/S:C/C:H/I:L/A:H) confirms that reachability and authentication prerequisites meaningfully narrow practical exposure. EPSS is very low at 0.07% (22nd percentile), no public exploit code has been identified at time of analysis, and the vulnerability is not listed in CISA KEV, so there is no indication of active exploitation.

Earlier versions of this analysis (1)
v1 Mar 15, 2026 - 14:04 CVSS 9.8

RemediationAI

No vendor-released patch or fixed firmware version is identified in the available data at the time of analysis, so administrators should track the INCIBE-CERT advisory (https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0) and Circutor's own security communications for an updated firmware release, applying it as soon as it is published. Until a patch exists, the most effective compensating control is strict network segmentation: keep SGE-PLC1000/SGE-PLC50 management interfaces off routable or internet-facing networks and confine them to isolated OT VLANs with firewall rules that permit access only from dedicated engineering workstations, since the attack path is adjacent-network (AV:A) rather than remote-internet. Complement this by auditing and aggressively minimizing the accounts that can invoke ShowMeterDatabase() and other parameter-driven diagnostic functions, enforcing least privilege and strong unique credentials to remove the low-privilege authenticated foothold the exploit requires; the trade-off is added administrative overhead and possible friction for legitimate maintenance workflows. Where the interface supports it, restrict management access to allowlisted source IPs and, if the function is not operationally required, disable or block access to the meter-database/diagnostic endpoint entirely - accepting the loss of that troubleshooting capability. Monitor device logs for malformed or abnormally long 'meter' parameter values and for unexpected process restarts as an early indicator of attempted exploitation, and validate any firmware update against the vendor's signed release before deployment in live grid environments.

Affected VersionsENISA

Circutor 9.0.2

Affected Packages

euvd circutor no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The flaw is a classic stack-based buffer overflow (CWE-121) rooted in an unbounded string copy. In firmware v9.0.2 of the Circutor SGE-PLC1000 and SGE-PLC50 - PLC concentrators used in smart-grid/energy distribution environments - the ShowMeterDatabase() routine reads a user-supplied 'meter' parameter via GetParameter(meter) and then formats it into a fixed-size stack buffer using sprintf() without any length validation. Because sprintf() does not bound its output, an oversized 'meter' value overflows adjacent stack memory, which can overwrite saved registers and the return address, leading to memory corruption, control-flow hijack, process crash, or arbitrary code execution depending on payload and platform mitigations. The affected CPEs are cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2 and cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2, confirming both device models at exactly that firmware revision. The CVSS 4.0 vector reflects adjacent-network access (AV:A), low privileges (PR:L), high confidentiality and availability impact with low integrity impact, and scope change (S:C), consistent with the 3.1 assessment that rates confidentiality and availability H and integrity L.

Know when Sge Plc1000 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (incibe) PRIMARY 8.5 HIGH
CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H
vuln.today AI 8.9 HIGH

Adjacent access and low-privilege auth are required (AV:A/PR:L); the memory corruption crosses into managed grid systems (S:C) with high confidentiality/availability but limited integrity impact, mirroring the vendor 4.0 profile.

3.1 AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:H
4.0 AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H

Primary rating from Vendor (incibe).

CVSS VectorVendor: incibe

Attack Vector
Adjacent
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
Low
Vulnerable system: Availability
High
Subsequent system: Confidentiality
High
Subsequent system: Integrity
Low
Subsequent system: Availability
High

Lifecycle Timeline

4
Severity Changed
Sep 26, 2026 - 00:22 NVD
CRITICAL HIGH
CVSS changed
Sep 26, 2026 - 00:22 NVD
9.8 (CRITICAL) 8.5 (HIGH)
CVE Published
Dec 02, 2025 - 13:15 cve.org
HIGH 8.5
CVE Published
Dec 02, 2025 - 13:15 nvd
CRITICAL 9.8

DescriptionCVE.org

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.

Executive ViewAI

Why It Matters

A critical stack-based buffer overflow vulnerability (CVE-2025-11784) affects Circutor SGE-PLC1000/SGE-PLC50 devices running version 9.0.2, with no patch currently available. Organizations using these industrial control systems face immediate risk of remote code execution and potential operational disruption.

Business Impact: Severe
Compensating Controls

Implement network segmentation to restrict access to SGE-PLC devices to trusted administrative networks only; deploy WAF rules to block oversized meter parameter inputs to the device interface; disable the ShowMeterDatabase() function if operationally feasible; enforce strict input validation at network boundary; implement comprehensive monitoring for exploitation attempts; maintain offline backups of critical configurations; establish incident response procedures for potential code execution.

Threat Intelligence Overview

EPSS Score
0.1%
Top 78% exploitable
Prevalence
Low
niche industrial smart-grid PLC concentrators, utility/OT deployments only
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
None
System Exposure· derived
Controlled
Automatable· derived
No
Human Impact
Very High

Priority Score

42
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +42
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.

CVE-2025-11785 CRITICAL
9.8 Dec 02

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' functi

CVE-2025-11778 CRITICAL
9.8 Dec 02

Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely

CVE-2025-11780 CRITICAL
9.8 Dec 02

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function,

CVE-2021-33841 CRITICAL
9.8 Jun 09

SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker

CVE-2025-11779 CRITICAL
9.4 Dec 02

Stack-based buffer overflow in the Circutor SGE-PLC1000 and SGE-PLC50 power line communication devices running firmware

CVE-2021-33842 HIGH
8.8 Jun 09

Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an

CVE-2025-11781 HIGH
8.6 Dec 02

Hardcoded cryptographic key exposure in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 lets an attacker who has loca

CVE-2025-11787 HIGH
8.5 Dec 02

Authenticated command injection in Circutor SGE-PLC1000 and SGE-PLC50 gateways running firmware 9.0.2 lets a low-privile

CVE-2025-11783 HIGH
8.5 Dec 02

A stack-based buffer overflow in the AddEvent() function of Circutor SGE-PLC1000 and SGE-PLC50 power-line communication

CVE-2025-11786 HIGH
8.5 Dec 02

Authenticated adjacent-network attackers can execute arbitrary shell commands on Circutor SGE-PLC1000 and SGE-PLC50 devi

CVE-2025-11782 HIGH
8.5 Dec 02

Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 allows authenticated attackers on an a

CVE-2025-11788 HIGH
8.5 Dec 02

Heap-based buffer overflow in the management interface of Circutor SGE-PLC1000 and SGE-PLC50 concentrators running firmw

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy