Skip to main content

Sge Plc1000 Firmware CVE-2025-11787

| EUVDEUVD-2025-200229 HIGH
OS Command Injection (CWE-78)
2025-12-02 cve-coordination@incibe.es
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

3
EUVD ID Assigned
Mar 15, 2026 - 14:04 euvd
EUVD-2025-200229
Analysis Generated
Mar 15, 2026 - 14:04 vuln.today
CVE Published
Dec 02, 2025 - 13:15 nvd
HIGH 8.8

DescriptionCVE.org

Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the 'GetDNS()', 'CheckPing()' and 'TraceRoute()' functions.

Analysis

Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the 'GetDNS()', 'CheckPing()' and 'TraceRoute()' functions.

Technical ContextAI

Command injection allows an attacker to execute arbitrary OS commands on the host system through a vulnerable application that passes user input to system shells. This vulnerability is classified as OS Command Injection (CWE-78).

RemediationAI

Avoid passing user input to system commands. Use language-specific APIs instead of shell commands. If unavoidable, use strict input validation and escaping.

CVE-2025-11779 CRITICAL
9.8 Dec 02

Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The 'SetLan' function is invoked when

CVE-2025-11783 CRITICAL
9.8 Dec 02

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The vulnerability is found in the 'A

CVE-2025-11786 CRITICAL
9.8 Dec 02

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'SetUserPassword()' function,

CVE-2025-11785 CRITICAL
9.8 Dec 02

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' functi

CVE-2025-11784 CRITICAL
9.8 Dec 02

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' functio

CVE-2025-11782 CRITICAL
9.8 Dec 02

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'ShowDownload()' function uses “

CVE-2025-11778 CRITICAL
9.8 Dec 02

Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely

CVE-2025-11788 CRITICAL
9.8 Dec 02

Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowSupervisorParameters()' f

CVE-2025-11780 CRITICAL
9.8 Dec 02

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function,

CVE-2021-33841 CRITICAL
9.8 Jun 09

SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker

CVE-2021-33842 HIGH
8.8 Jun 09

Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an

CVE-2025-11781 HIGH
7.8 Dec 02

Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded

Share

CVE-2025-11787 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy