An out-of-bounds read in the Circutor SGE-PLC1000 and SGE-PLC50 power-line communication concentrators running firmware 9.0.2 allows an authenticated user of the device's management interface to read memory beyond the bounds of the internal FilesDownload array. The DownloadFile function passes an attacker-supplied parameter through atoi() and then uses the resulting value directly as an array index, so an unusually large numeric value causes an out-of-bounds access that discloses adjacent memory contents; impact is limited to confidentiality (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N), with no integrity or availability effect and no code execution. Credentials are required to reach the vulnerable code path, EPSS places exploitation likelihood at roughly 0.05% (14th percentile), and no public exploit or confirmed active exploitation was identified at time of analysis.
Heap-based buffer overflow in the management interface of Circutor SGE-PLC1000 and SGE-PLC50 concentrators running firmware 9.0.2 lets an attacker who can reach the device over the network and authenticate with low privileges corrupt heap memory by supplying an oversized 'meter' parameter, yielding high confidentiality and availability impact without any user interaction. The flaw sits in ShowSupervisorParameters(), which passes the unbounded 'meter' value obtained through GetParameter(meter) into a fixed-size buffer via sprintf(). No public exploit code has been identified at time of analysis, and the EPSS score is low at 0.06% (20th percentile), so risk is driven primarily by exposure of the concentrator's management interface rather than by observed exploitation activity.
Authenticated command injection in Circutor SGE-PLC1000 and SGE-PLC50 gateways running firmware 9.0.2 lets a low-privilege user of the management interface run arbitrary operating-system commands through the GetDNS(), CheckPing() and TraceRoute() diagnostic functions, which pass unsanitized input to the underlying shell. The vendor scores this 8.5 under CVSS 4.0 with PR:L and UI:A, and our independent CVSS 3.1 assessment agrees on high confidentiality, integrity and availability impact while emphasizing that exploitation is gated behind a valid authenticated session and the ICS deployment context. EPSS is low at 0.29% (52nd percentile), the CVE is not in CISA KEV, and no public exploit code was identified at time of analysis, so this is a genuine but access-gated flaw rather than an internet-exposed, unauthenticated remote compromise.
Authenticated adjacent-network attackers can execute arbitrary shell commands on Circutor SGE-PLC1000 and SGE-PLC50 devices running firmware 9.0.2 by supplying shell metacharacters in the newPassword parameter of SetUserPassword(). The flaw combines an unsanitized sprintf() path into system() with CWE-121 stack-based buffer overflow conditions, requiring valid low-privilege access on the same network segment and no user interaction; it enables high confidentiality and availability impact and potential scope change onto subsequent systems. No public exploit code or CISA KEV listing was identified at time of analysis, and EPSS is 0.07% (22nd percentile).
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 smart-grid PLC concentrators running firmware v9.0.2 allows an attacker to corrupt memory and potentially achieve code execution or a denial-of-service condition by supplying an excessively long 'meter' parameter that is copied into a fixed-size stack buffer via sprintf() inside the ShowMeterDatabase() function. Exploitation requires the attacker to already reside on the adjacent network (same LAN/OT segment) and to hold valid low-privilege credentials, since the parameter is reached through an authenticated management function; the CVE carries a base CVSS of 8.5, though our independent assessment (CVSS 3.1 AV:A/PR:L/S:C/C:H/I:L/A:H) confirms that reachability and authentication prerequisites meaningfully narrow practical exposure. EPSS is very low at 0.07% (22nd percentile), no public exploit code has been identified at time of analysis, and the vulnerability is not listed in CISA KEV, so there is no indication of active exploitation.
A stack-based buffer overflow in the AddEvent() function of Circutor SGE-PLC1000 and SGE-PLC50 power-line communication devices running firmware v9.0.2 lets an attacker with adjacent-network access and valid low-privilege credentials overwrite a fixed 48-byte stack buffer using an over-long username, causing memory corruption and potentially remote code execution. Per the CVSS 4.0 vector (8.5) the attacker requires both adjacency to the same L2/management or substation segment (AV:A) and authentication (PR:L), with no user interaction, though exploit reliability for full code execution is described only as 'possible' and may be uncertain. No public exploit code was identified at time of analysis and EPSS is low at 0.24% (47th percentile), so real-world priority is better captured as MEDIUM despite the high base score.
Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 allows authenticated attackers on an adjacent network to overflow a 64-byte stack buffer via a crafted 'meter' parameter to the ShowDownload() function, potentially achieving code execution or denial of service. The vulnerability requires low-privileged credentials and local network access, and no public exploit has been identified at time of analysis (EPSS 0.07%).
Hardcoded cryptographic key exposure in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 lets an attacker who has local access to the device recover the embedded static authentication key from the firmware image or a memory dump and then forge firmware update packages that the device accepts as genuine, effectively bypassing access controls and obtaining full administrative privileges. The weakness is access-gated rather than remotely reachable: the CVSS vector is AV:L (local) with PR:N (no authentication required once local access is achieved), and the assessed CVSS:3.1 score is 8.6-equivalent (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). No public exploit code has been identified at time of analysis and the EPSS score is only 0.02% (percentile 6%), so this is a genuine but low-volume, physically/local-scoped risk concentrated in these two Circutor product lines at firmware version 9.0.2.
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the “meter” parameter.
Stack-based buffer overflow in the Circutor SGE-PLC1000 and SGE-PLC50 power line communication devices running firmware v9.0.2 allows an authenticated attacker on the adjacent management/OT network to corrupt memory and potentially achieve command execution on the device. The flaw lives in the SetLan routine, which is invoked from the index.cgi web application whenever an operator submits a new LAN/network configuration; the submitted parameters are not sanitised before being copied into a fixed-size stack buffer. Exploitation requires network reachability to the device's management web interface plus a valid low-privilege session (CVSS 4.0 AV:A/PR:L; assessed CVSS 3.1 AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H), and no public exploit code or confirmed active exploitation was identified at time of analysis, although EPSS places the flaw at roughly the 83rd percentile (1.97%) of predicted exploitation activity.
Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely exploit memory corruption through the 'read_packet()' function of the TACACSPLUS implementation.
An out-of-bounds read in the Circutor SGE-PLC1000 and SGE-PLC50 power-line communication concentrators running firmware 9.0.2 allows an authenticated user of the device's management interface to read memory beyond the bounds of the internal FilesDownload array. The DownloadFile function passes an attacker-supplied parameter through atoi() and then uses the resulting value directly as an array index, so an unusually large numeric value causes an out-of-bounds access that discloses adjacent memory contents; impact is limited to confidentiality (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N), with no integrity or availability effect and no code execution. Credentials are required to reach the vulnerable code path, EPSS places exploitation likelihood at roughly 0.05% (14th percentile), and no public exploit or confirmed active exploitation was identified at time of analysis.
Heap-based buffer overflow in the management interface of Circutor SGE-PLC1000 and SGE-PLC50 concentrators running firmware 9.0.2 lets an attacker who can reach the device over the network and authenticate with low privileges corrupt heap memory by supplying an oversized 'meter' parameter, yielding high confidentiality and availability impact without any user interaction. The flaw sits in ShowSupervisorParameters(), which passes the unbounded 'meter' value obtained through GetParameter(meter) into a fixed-size buffer via sprintf(). No public exploit code has been identified at time of analysis, and the EPSS score is low at 0.06% (20th percentile), so risk is driven primarily by exposure of the concentrator's management interface rather than by observed exploitation activity.
Authenticated command injection in Circutor SGE-PLC1000 and SGE-PLC50 gateways running firmware 9.0.2 lets a low-privilege user of the management interface run arbitrary operating-system commands through the GetDNS(), CheckPing() and TraceRoute() diagnostic functions, which pass unsanitized input to the underlying shell. The vendor scores this 8.5 under CVSS 4.0 with PR:L and UI:A, and our independent CVSS 3.1 assessment agrees on high confidentiality, integrity and availability impact while emphasizing that exploitation is gated behind a valid authenticated session and the ICS deployment context. EPSS is low at 0.29% (52nd percentile), the CVE is not in CISA KEV, and no public exploit code was identified at time of analysis, so this is a genuine but access-gated flaw rather than an internet-exposed, unauthenticated remote compromise.
Authenticated adjacent-network attackers can execute arbitrary shell commands on Circutor SGE-PLC1000 and SGE-PLC50 devices running firmware 9.0.2 by supplying shell metacharacters in the newPassword parameter of SetUserPassword(). The flaw combines an unsanitized sprintf() path into system() with CWE-121 stack-based buffer overflow conditions, requiring valid low-privilege access on the same network segment and no user interaction; it enables high confidentiality and availability impact and potential scope change onto subsequent systems. No public exploit code or CISA KEV listing was identified at time of analysis, and EPSS is 0.07% (22nd percentile).
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 smart-grid PLC concentrators running firmware v9.0.2 allows an attacker to corrupt memory and potentially achieve code execution or a denial-of-service condition by supplying an excessively long 'meter' parameter that is copied into a fixed-size stack buffer via sprintf() inside the ShowMeterDatabase() function. Exploitation requires the attacker to already reside on the adjacent network (same LAN/OT segment) and to hold valid low-privilege credentials, since the parameter is reached through an authenticated management function; the CVE carries a base CVSS of 8.5, though our independent assessment (CVSS 3.1 AV:A/PR:L/S:C/C:H/I:L/A:H) confirms that reachability and authentication prerequisites meaningfully narrow practical exposure. EPSS is very low at 0.07% (22nd percentile), no public exploit code has been identified at time of analysis, and the vulnerability is not listed in CISA KEV, so there is no indication of active exploitation.
A stack-based buffer overflow in the AddEvent() function of Circutor SGE-PLC1000 and SGE-PLC50 power-line communication devices running firmware v9.0.2 lets an attacker with adjacent-network access and valid low-privilege credentials overwrite a fixed 48-byte stack buffer using an over-long username, causing memory corruption and potentially remote code execution. Per the CVSS 4.0 vector (8.5) the attacker requires both adjacency to the same L2/management or substation segment (AV:A) and authentication (PR:L), with no user interaction, though exploit reliability for full code execution is described only as 'possible' and may be uncertain. No public exploit code was identified at time of analysis and EPSS is low at 0.24% (47th percentile), so real-world priority is better captured as MEDIUM despite the high base score.
Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 allows authenticated attackers on an adjacent network to overflow a 64-byte stack buffer via a crafted 'meter' parameter to the ShowDownload() function, potentially achieving code execution or denial of service. The vulnerability requires low-privileged credentials and local network access, and no public exploit has been identified at time of analysis (EPSS 0.07%).
Hardcoded cryptographic key exposure in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 lets an attacker who has local access to the device recover the embedded static authentication key from the firmware image or a memory dump and then forge firmware update packages that the device accepts as genuine, effectively bypassing access controls and obtaining full administrative privileges. The weakness is access-gated rather than remotely reachable: the CVSS vector is AV:L (local) with PR:N (no authentication required once local access is achieved), and the assessed CVSS:3.1 score is 8.6-equivalent (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). No public exploit code has been identified at time of analysis and the EPSS score is only 0.02% (percentile 6%), so this is a genuine but low-volume, physically/local-scoped risk concentrated in these two Circutor product lines at firmware version 9.0.2.
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the “meter” parameter.
Stack-based buffer overflow in the Circutor SGE-PLC1000 and SGE-PLC50 power line communication devices running firmware v9.0.2 allows an authenticated attacker on the adjacent management/OT network to corrupt memory and potentially achieve command execution on the device. The flaw lives in the SetLan routine, which is invoked from the index.cgi web application whenever an operator submits a new LAN/network configuration; the submitted parameters are not sanitised before being copied into a fixed-size stack buffer. Exploitation requires network reachability to the device's management web interface plus a valid low-privilege session (CVSS 4.0 AV:A/PR:L; assessed CVSS 3.1 AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H), and no public exploit code or confirmed active exploitation was identified at time of analysis, although EPSS places the flaw at roughly the 83rd percentile (1.97%) of predicted exploitation activity.
Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely exploit memory corruption through the 'read_packet()' function of the TACACSPLUS implementation.