Circutor SGE-PLC1000 CVE-2025-11788

| EUVDEUVD-2025-200228 HIGH
Heap-based Buffer Overflow (CWE-122)
2025-12-02 cve-coordination@incibe.es
8.5
CVSS 4.0 · Vendor: incibe
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Obtain low-privilege device credentials
  2. Delivery
    Send oversized 'meter' parameter
  3. Exploit
    Overflow fixed-size heap buffer via sprintf()
  4. Execution
    Corrupt heap memory / crash service
  5. Impact
    Disrupt or control grid concentrator

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Heap buffer bounds checking
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Requires network access to the device management interface and valid low-privilege authentication (CVSS PR:L) to reach the vulnerable ShowSupervisorParameters()/GetParameter(meter) code path on Circutor SGE-PLC1000 or SGE-PLC50 firmware v9.0.2; the attacker must supply an oversized 'meter' parameter value. No user interaction is needed. Limiting factors: authentication is mandatory (not unauthenticated), only firmware 9.0.2 is confirmed affected, and real-world reachability depends on whether the concentrator's management interface is exposed beyond the utility/OT network.

Impact

The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H with subsequent-system SC:H/SA:H) scores 8.5 and indicates a network-reachable heap overflow requiring only low privileges and no user interaction, with high confidentiality and availability impact plus a scope change onto downstream systems. However, exploitation signals point to low real-world urgency: EPSS is only 0.06% (20th percentile), there is no CISA KEV listing, and no public proof-of-concept is referenced in the INCIBE advisory or NVD entry. The PR:L requirement means an attacker must already hold valid (even low-level) credentials to the device's web/management interface, which meaningfully limits opportunistic mass exploitation. The vendor sets VI:N (no integrity impact) which is somewhat conservative for a classic sprintf() heap overflow that could plausibly enable memory corruption and code execution; whether this yields only DoS/info-leak or full code execution is not established in the available data and should be verified with Circutor/INCIBE. Net: a genuinely dangerous class of bug (heap overflow in OT gear) but currently a moderate priority given authentication gating, very low EPSS, no KEV, and no known exploit - patch on a normal OT maintenance cycle unless the device is internet-exposed.

Exploit ScenarioDerived

An attacker who has obtained low-privilege credentials to the SGE-PLC1000/SGE-PLC50 management interface sends a crafted request whose 'meter' parameter is excessively long; ShowSupervisorParameters() passes it through GetParameter(meter) into a fixed-size buffer via sprintf() with no bounds check, overflowing the heap. This causes device crash/denial of service and potentially memory corruption leading to code execution on the concentrator. No public exploit code is referenced at the time of analysis.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv2 – Sep 26, 2026

Heap-based buffer overflow in the management interface of Circutor SGE-PLC1000 and SGE-PLC50 concentrators running firmware 9.0.2 lets an attacker who can reach the device over the network and authenticate with low privileges corrupt heap memory by supplying an oversized 'meter' parameter, yielding high confidentiality and availability impact without any user interaction. The flaw sits in ShowSupervisorParameters(), which passes the unbounded 'meter' value obtained through GetParameter(meter) into a fixed-size buffer via sprintf(). No public exploit code has been identified at time of analysis, and the EPSS score is low at 0.06% (20th percentile), so risk is driven primarily by exposure of the concentrator's management interface rather than by observed exploitation activity.

Earlier versions of this analysis (1)
v1 Mar 15, 2026 - 14:04 CVSS 9.8

RemediationAI

No vendor-released patch version is identified in the available data for CVE-2025-11788, so the primary action is to track the INCIBE-CERT advisory (https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0) and the NVD entry (https://nvd.nist.gov/vuln/detail/CVE-2025-11788) for a Circutor firmware update covering SGE-PLC1000/SGE-PLC50 9.0.2, and to apply it as soon as Circutor publishes a fixed release. In the interim, the most effective compensating control is to remove network reachability to the concentrator's management interface: place SGE-PLC1000/SGE-PLC50 devices on a dedicated OT/utility VLAN, block management-port access from corporate or internet-facing networks at the firewall, and allow only the specific administrative jump hosts that require access, accepting that this constrains remote administration and any centralized monitoring that relies on those ports. Where the web management service is not operationally required, disable it or restrict it to local/console administration only, at the cost of losing remote configuration capability. Because the vulnerable path requires valid low-privilege credentials (CVSS PR:L in both the 4.0 and 3.1 assessments), enforce unique strong credentials, remove or disable unused accounts, and change default passwords to reduce who can reach ShowSupervisorParameters() at all. Add IDS/IPS or device-log monitoring for abnormally long 'meter' parameter values and for repeated management-interface crashes or restarts, which are the observable signs of attempted exploitation (note that this is detection, not prevention, and produces false positives on legitimate bulk configuration traffic).

Affected VersionsENISA

Circutor 9.0.2

Affected Packages

euvd circutor no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The affected devices are Circutor SGE-PLC1000 and SGE-PLC50 firmware 9.0.2 (CPE cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2 and cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2), power-line-communication concentrators used in smart-metering and industrial/OT deployments to aggregate data from downstream meters. The vulnerability is CWE-122 (heap-based buffer overflow): the function ShowSupervisorParameters() accepts a user-controlled string through GetParameter(meter) and writes it into a heap-allocated buffer of fixed size using sprintf(), a routine that performs no bounds checking. Because no length validation is applied, an oversized 'meter' parameter overflows the destination buffer, corrupting adjacent heap metadata and objects; depending on allocation layout this can crash the process (availability impact), leak memory contents (confidentiality impact), or, in principle, be shaped toward further corruption of the concentrator's process state. Any attack surface is the web/management interface of the concentrator, which is normally reachable only from the utility or OT network.

Know when Sge Plc1000 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (incibe) PRIMARY 8.5 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:H/SI:N/SA:H
vuln.today AI 8.1 HIGH

Network-reachable and low-complexity but gated by low-privilege authentication (PR:L); heap overflow yields memory disclosure (C:H) and crash/DoS (A:H), with integrity impact unproven (I:N).

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (incibe).

CVSS VectorVendor: incibe

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
None
Vulnerable system: Availability
High
Subsequent system: Confidentiality
High
Subsequent system: Integrity
None
Subsequent system: Availability
High

Lifecycle Timeline

4
Severity Changed
Sep 26, 2026 - 00:22 NVD
CRITICAL HIGH
CVSS changed
Sep 26, 2026 - 00:22 NVD
9.8 (CRITICAL) 8.5 (HIGH)
CVE Published
Dec 02, 2025 - 13:15 cve.org
HIGH 8.5
CVE Published
Dec 02, 2025 - 13:15 nvd
CRITICAL 9.8

DescriptionCVE.org

Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowSupervisorParameters()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.

Executive ViewAI

Why It Matters

A critical heap buffer overflow vulnerability (CVE-2025-11788) affects Circutor SGE-PLC1000/SGE-PLC50 devices running v9.0.2, allowing unauthenticated remote attackers to execute arbitrary code with no patch currently available. Organizations operating these industrial control devices face immediate risk of system compromise, operational disruption, and potential safety incidents if exploited.

Business Impact: Severe
Compensating Controls

Implement network segmentation to restrict access to SGE-PLC devices to authorized networks only; deploy WAF/IDS rules to detect and block oversized meter parameter inputs and buffer overflow attack patterns; disable the ShowSupervisorParameters() function if operationally feasible; restrict administrative access via IP whitelisting; enable detailed logging and alerting on parameter input anomalies; consider deploying an intrusion prevention system (IPS) in line with affected device traffic; implement rate limiting on parameter API endpoints; monitor Circutor security advisories closely for patch release.

Threat Intelligence Overview

EPSS Score
0.1%
Top 80% exploitable
Prevalence
Low
niche Circutor smart-grid PLC data concentrators, utility/industrial deployment only
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact
Very High

Priority Score

42
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +42
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

A heap overflow occurs when a program writes data beyond the bounds of a buffer allocated in the heap memory region.

CVE-2025-11785 CRITICAL
9.8 Dec 02

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' functi

CVE-2025-11778 CRITICAL
9.8 Dec 02

Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely

CVE-2025-11780 CRITICAL
9.8 Dec 02

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function,

CVE-2021-33841 CRITICAL
9.8 Jun 09

SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker

CVE-2025-11779 CRITICAL
9.4 Dec 02

Stack-based buffer overflow in the Circutor SGE-PLC1000 and SGE-PLC50 power line communication devices running firmware

CVE-2021-33842 HIGH
8.8 Jun 09

Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an

CVE-2025-11781 HIGH
8.6 Dec 02

Hardcoded cryptographic key exposure in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 lets an attacker who has loca

CVE-2025-11787 HIGH
8.5 Dec 02

Authenticated command injection in Circutor SGE-PLC1000 and SGE-PLC50 gateways running firmware 9.0.2 lets a low-privile

CVE-2025-11783 HIGH
8.5 Dec 02

A stack-based buffer overflow in the AddEvent() function of Circutor SGE-PLC1000 and SGE-PLC50 power-line communication

CVE-2025-11786 HIGH
8.5 Dec 02

Authenticated adjacent-network attackers can execute arbitrary shell commands on Circutor SGE-PLC1000 and SGE-PLC50 devi

CVE-2025-11784 HIGH
8.5 Dec 02

Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 smart-grid PLC concentrators running firmware v9.0.2 a

CVE-2025-11782 HIGH
8.5 Dec 02

Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 allows authenticated attackers on an a

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy