Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessObtain low-privilege device credentials
-
DeliverySend oversized 'meter' parameter
-
ExploitOverflow fixed-size heap buffer via sprintf()
-
ExecutionCorrupt heap memory / crash service
-
ImpactDisrupt or control grid concentrator
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Heap buffer bounds checking
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Requires network access to the device management interface and valid low-privilege authentication (CVSS PR:L) to reach the vulnerable ShowSupervisorParameters()/GetParameter(meter) code path on Circutor SGE-PLC1000 or SGE-PLC50 firmware v9.0.2; the attacker must supply an oversized 'meter' parameter value. No user interaction is needed. Limiting factors: authentication is mandatory (not unauthenticated), only firmware 9.0.2 is confirmed affected, and real-world reachability depends on whether the concentrator's management interface is exposed beyond the utility/OT network. |
| Impact | The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H with subsequent-system SC:H/SA:H) scores 8.5 and indicates a network-reachable heap overflow requiring only low privileges and no user interaction, with high confidentiality and availability impact plus a scope change onto downstream systems. However, exploitation signals point to low real-world urgency: EPSS is only 0.06% (20th percentile), there is no CISA KEV listing, and no public proof-of-concept is referenced in the INCIBE advisory or NVD entry. The PR:L requirement means an attacker must already hold valid (even low-level) credentials to the device's web/management interface, which meaningfully limits opportunistic mass exploitation. The vendor sets VI:N (no integrity impact) which is somewhat conservative for a classic sprintf() heap overflow that could plausibly enable memory corruption and code execution; whether this yields only DoS/info-leak or full code execution is not established in the available data and should be verified with Circutor/INCIBE. Net: a genuinely dangerous class of bug (heap overflow in OT gear) but currently a moderate priority given authentication gating, very low EPSS, no KEV, and no known exploit - patch on a normal OT maintenance cycle unless the device is internet-exposed. |
| Exploit ScenarioDerived | An attacker who has obtained low-privilege credentials to the SGE-PLC1000/SGE-PLC50 management interface sends a crafted request whose 'meter' parameter is excessively long; ShowSupervisorParameters() passes it through GetParameter(meter) into a fixed-size buffer via sprintf() with no bounds check, overflowing the heap. This causes device crash/denial of service and potentially memory corruption leading to code execution on the concentrator. No public exploit code is referenced at the time of analysis. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv2 – Sep 26, 2026
Heap-based buffer overflow in the management interface of Circutor SGE-PLC1000 and SGE-PLC50 concentrators running firmware 9.0.2 lets an attacker who can reach the device over the network and authenticate with low privileges corrupt heap memory by supplying an oversized 'meter' parameter, yielding high confidentiality and availability impact without any user interaction. The flaw sits in ShowSupervisorParameters(), which passes the unbounded 'meter' value obtained through GetParameter(meter) into a fixed-size buffer via sprintf(). No public exploit code has been identified at time of analysis, and the EPSS score is low at 0.06% (20th percentile), so risk is driven primarily by exposure of the concentrator's management interface rather than by observed exploitation activity.
Earlier versions of this analysis (1)
RemediationAI
No vendor-released patch version is identified in the available data for CVE-2025-11788, so the primary action is to track the INCIBE-CERT advisory (https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0) and the NVD entry (https://nvd.nist.gov/vuln/detail/CVE-2025-11788) for a Circutor firmware update covering SGE-PLC1000/SGE-PLC50 9.0.2, and to apply it as soon as Circutor publishes a fixed release. In the interim, the most effective compensating control is to remove network reachability to the concentrator's management interface: place SGE-PLC1000/SGE-PLC50 devices on a dedicated OT/utility VLAN, block management-port access from corporate or internet-facing networks at the firewall, and allow only the specific administrative jump hosts that require access, accepting that this constrains remote administration and any centralized monitoring that relies on those ports. Where the web management service is not operationally required, disable it or restrict it to local/console administration only, at the cost of losing remote configuration capability. Because the vulnerable path requires valid low-privilege credentials (CVSS PR:L in both the 4.0 and 3.1 assessments), enforce unique strong credentials, remove or disable unused accounts, and change default passwords to reduce who can reach ShowSupervisorParameters() at all. Add IDS/IPS or device-log monitoring for abnormally long 'meter' parameter values and for repeated management-interface crashes or restarts, which are the observable signs of attempted exploitation (note that this is detection, not prevention, and produces false positives on legitimate bulk configuration traffic).
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The affected devices are Circutor SGE-PLC1000 and SGE-PLC50 firmware 9.0.2 (CPE cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2 and cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2), power-line-communication concentrators used in smart-metering and industrial/OT deployments to aggregate data from downstream meters. The vulnerability is CWE-122 (heap-based buffer overflow): the function ShowSupervisorParameters() accepts a user-controlled string through GetParameter(meter) and writes it into a heap-allocated buffer of fixed size using sprintf(), a routine that performs no bounds checking. Because no length validation is applied, an oversized 'meter' parameter overflows the destination buffer, corrupting adjacent heap metadata and objects; depending on allocation layout this can crash the process (availability impact), leak memory contents (confidentiality impact), or, in principle, be shaped toward further corruption of the concentrator's process state. Any attack surface is the web/management interface of the concentrator, which is normally reachable only from the utility or OT network.
Know when Sge Plc1000 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:H/SI:N/SA:H
Network-reachable and low-complexity but gated by low-privilege authentication (PR:L); heap overflow yields memory disclosure (C:H) and crash/DoS (A:H), with integrity impact unproven (I:N).
Primary rating from Vendor (incibe).
CVSS VectorVendor: incibe
Lifecycle Timeline
4DescriptionCVE.org
Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowSupervisorParameters()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
Executive ViewAI
A critical heap buffer overflow vulnerability (CVE-2025-11788) affects Circutor SGE-PLC1000/SGE-PLC50 devices running v9.0.2, allowing unauthenticated remote attackers to execute arbitrary code with no patch currently available. Organizations operating these industrial control devices face immediate risk of system compromise, operational disruption, and potential safety incidents if exploited.
Implement network segmentation to restrict access to SGE-PLC devices to authorized networks only; deploy WAF/IDS rules to detect and block oversized meter parameter inputs and buffer overflow attack patterns; disable the ShowSupervisorParameters() function if operationally feasible; restrict administrative access via IP whitelisting; enable detailed logging and alerting on parameter input anomalies; consider deploying an intrusion prevention system (IPS) in line with affected device traffic; implement rate limiting on parameter API endpoints; monitor Circutor security advisories closely for patch release.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
A heap overflow occurs when a program writes data beyond the bounds of a buffer allocated in the heap memory region.
More in Sge Plc1000 Firmware
View allStack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' functi
Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function,
SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker
Stack-based buffer overflow in the Circutor SGE-PLC1000 and SGE-PLC50 power line communication devices running firmware
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an
Hardcoded cryptographic key exposure in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 lets an attacker who has loca
Authenticated command injection in Circutor SGE-PLC1000 and SGE-PLC50 gateways running firmware 9.0.2 lets a low-privile
A stack-based buffer overflow in the AddEvent() function of Circutor SGE-PLC1000 and SGE-PLC50 power-line communication
Authenticated adjacent-network attackers can execute arbitrary shell commands on Circutor SGE-PLC1000 and SGE-PLC50 devi
Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 smart-grid PLC concentrators running firmware v9.0.2 a
Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 allows authenticated attackers on an a
EUVD-2025-200228
NVD
CVE.org
EPSS
VulDB
GitHub PoC
Exploit-DB