Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessObtain local access to device
-
DeliveryDump firmware image or memory
-
ExploitExtract hardcoded static key
-
ExecutionForge signed firmware update package
-
PersistInstall malicious firmware
-
ImpactGain full administrative control
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A04:2025 - Cryptographic Failures
ASVS 5.0
V11 - Cryptography Key management, no hard-coded keys
|
| Exploitation Conditions | Requires local access to the device to read the firmware image or a memory dump and recover the embedded static authentication key (the key is hardcoded and identical across the SGE-PLC1000/SGE-PLC50 v9.0.2 firmware line). With the key, the attacker forges a firmware update package that satisfies the device's authentication/integrity checks, so the practical prerequisite is the ability to deliver a firmware update (local management interface or maintenance channel). Limiting factors: no remote network vector (AV:L), exploitation is physical/logical-local, and it is confined to firmware version 9.0.2 of these two Circutor product lines; no user interaction by a victim is needed once local access is achieved. |
| Impact | This is a genuine but access-gated weakness rather than a mass-exploitable emergency. The vendor CVSS 4.0 vector (AV:L/AC:L/PR:N/UI:N, VC:H/VI:H/VA:H, 8.6) correctly encodes the core constraint: exploitation requires LOCAL access to the device (AV:L), after which the hardcoded static key can be extracted from a firmware image or memory dump and used to forge fully valid firmware update packages granting full administrative control. The high 8.6 comes from full CIA impact, not from remote reachability. All signals point AWAY from imminent widespread abuse: EPSS is 0.02% (6th percentile), there is no CISA KEV listing (no public exploit identified at time of analysis), and no POC is referenced - only the INCIBE-CERT vendor advisory. There is no SSVC data in the input. Note a scope tension worth verifying: the CVSS 4.0 vector lists PR:N (no privileges) yet the description requires local access to extract the key - PR:N here reflects that no login/authentication is needed once physical or logical local access is obtained, not that the flaw is remotely reachable; defenders should read AV:L as the true gate. Because the key is static and shared across the firmware line, a single extraction yields a class-break capability (forge firmware for any device of that model/version), which raises long-term risk despite the low near-term exploitation probability - this is a targeted-attacker / supply-chain concern rather than an internet-worm concern. |
| Exploit ScenarioDerived | An attacker with local access to a Circutor SGE-PLC1000 or SGE-PLC50 concentrator (physical access, a compromised maintenance workstation, or an extracted firmware image) analyzes the firmware or a memory dump to recover the hardcoded static authentication key. Using that key they craft a firmware update package that passes all integrity/authentication checks, install it, and obtain full administrative control of the smart-grid PLC device. No public exploit or POC is currently identified, and exploitation is gated by the local-access requirement. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv2 – Sep 26, 2026
Hardcoded cryptographic key exposure in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 lets an attacker who has local access to the device recover the embedded static authentication key from the firmware image or a memory dump and then forge firmware update packages that the device accepts as genuine, effectively bypassing access controls and obtaining full administrative privileges. The weakness is access-gated rather than remotely reachable: the CVSS vector is AV:L (local) with PR:N (no authentication required once local access is achieved), and the assessed CVSS:3.1 score is 8.6-equivalent (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). No public exploit code has been identified at time of analysis and the EPSS score is only 0.02% (percentile 6%), so this is a genuine but low-volume, physically/local-scoped risk concentrated in these two Circutor product lines at firmware version 9.0.2.
Earlier versions of this analysis (1)
RemediationAI
No vendor-released patch has been identified at time of analysis; check the INCIBE-CERT advisory (https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0) and the NVD entry (https://nvd.nist.gov/vuln/detail/CVE-2025-11781) for an updated firmware release, and contact Circutor directly for a fixed image before assuming one exists. Because the defect is an embedded static key that cannot be rotated without new firmware, prioritize compensating controls: enforce strict physical and maintenance-channel access control so unauthorized parties cannot read the firmware image, memory, or the update interface (this is the primary barrier, since the attack requires local access - trade-off is operational overhead for field service and tamper-evident enclosures/seals); block or disable remote/diagnostic firmware-update paths such as vendor update servers, TFTP/USB update routines, and maintenance ports on any device that does not strictly require them (trade-off: field updates must then be performed manually through a hardened, supervised procedure); and segment these devices onto an isolated OT network with no inbound path to management interfaces so a compromised neighbor cannot reach the update channel (trade-off: complicates remote monitoring and telemetry). Until a fixed image exists, verify firmware integrity by comparing cryptographic hashes of update packages against an out-of-band, vendor-published baseline before installation, and monitor device logs for unexpected firmware flashes or configuration resets as an indicator of abuse. Given the low EPSS (0.02%, percentile 6%) and absence of any identified public exploit, these measures can be staged rather than treated as an emergency, but devices with untrusted physical access should be remediated first.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The issue is a classic CWE-321 (Use of Hard-coded Cryptographic Key) defect in the firmware of Circutor's SGE-PLC1000 and SGE-PLC50 devices, which are power-line-communication/concentrator-class units used in industrial and smart-metering deployments. Instead of generating or securely provisioning a per-device signing/authentication key, the firmware ships a single static key that is identical across the whole v9.0.2 firmware line; that key gates the integrity/authenticity check applied to firmware update packages. Because firmware images are frequently extractable (via vendor update files, JTAG, or a simple memory dump on a device to which the attacker has physical or maintenance access), the key material is recoverable rather than protected. Once recovered, the attacker can sign or package arbitrary firmware that satisfies the device's own validation logic, so the update mechanism - the very control intended to prevent unauthorized code from running - becomes the delivery vehicle for full administrative compromise. CPE data confirms the affected surface as cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2 and cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2, and EUVD lists the affected version simply as Circutor 9.0.2. The independent assessment stresses that exploitation is confined to firmware version 9.0.2 of these two product lines and requires local/logical access plus the ability to deliver a firmware update (local management interface or maintenance channel); there is no remote network vector.
Know when Sge Plc1000 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Local access needed to extract the key and push firmware (AV:L), but no authentication once local (PR:N); forged firmware yields full admin so C/I/A all High.
Primary rating from Vendor (incibe).
CVSS VectorVendor: incibe
Lifecycle Timeline
3DescriptionCVE.org
Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create valid firmware update packages. This bypasses all intended access controls and grants full administrative privileges.
Executive ViewAI
Circutor SGE-PLC1000/SGE-PLC50 devices running firmware v9.0.2 contain hardcoded cryptographic keys that allow attackers with local access to bypass authentication and gain administrative control. Organizations using these industrial control devices face immediate risk of unauthorized firmware modification and system compromise, with no vendor patch currently available.
Implement strict physical access controls to prevent local device access; disable or restrict firmware update functionality where operationally feasible; segment affected devices from corporate networks and critical infrastructure; monitor device logs and firmware integrity; require multi-factor authentication for any administrative access; perform regular firmware integrity verification; consider temporary isolation of non-critical affected devices pending patch availability.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
More in Sge Plc1000 Firmware
View allStack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' functi
Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function,
SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker
Stack-based buffer overflow in the Circutor SGE-PLC1000 and SGE-PLC50 power line communication devices running firmware
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an
Authenticated command injection in Circutor SGE-PLC1000 and SGE-PLC50 gateways running firmware 9.0.2 lets a low-privile
A stack-based buffer overflow in the AddEvent() function of Circutor SGE-PLC1000 and SGE-PLC50 power-line communication
Authenticated adjacent-network attackers can execute arbitrary shell commands on Circutor SGE-PLC1000 and SGE-PLC50 devi
Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 smart-grid PLC concentrators running firmware v9.0.2 a
Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 allows authenticated attackers on an a
Heap-based buffer overflow in the management interface of Circutor SGE-PLC1000 and SGE-PLC50 concentrators running firmw
EUVD-2025-200235
NVD
CVE.org
EPSS
VulDB
GitHub PoC
Exploit-DB