Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessAuthenticate to device management interface
-
DeliveryAccess network diagnostic function (GetDNS/CheckPing/TraceRoute)
-
ExploitInject shell metacharacters into diagnostic parameter
-
ExecutionExecute arbitrary OS commands on device
-
ImpactFull compromise of grid concentrator
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK
2 techniques across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Requires an authenticated low-privilege session on the Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 management interface, then invocation of the built-in network diagnostic features backed by the GetDNS(), CheckPing() or TraceRoute() functions, into which shell metacharacters are injected. Limiting factors: authentication is mandatory (PR:L), the specific firmware version 9.0.2 must be running, the affected diagnostic functionality must be reachable, and the vendor's CVSS 4.0 marks user interaction as required (UI:A) - reducing realistic risk below the raw network-vector score. Exposure is further bounded by the ICS deployment context, where these devices are typically on segmented operational networks rather than the open internet. |
| Impact | This is a genuine but access-gated flaw. The CVSS 4.0 vector (AV:N/AC:L/PR:L/UI:A/VC:H/VI:H/VA:H) scores 8.5 and describes network-reachable, low-complexity OS command injection yielding full compromise of the device OS - but two factors temper it: PR:L means an authenticated (albeit low-privilege) session is required, and the vendor asserts UI:A (active user interaction). EPSS is low at 0.29% (52nd percentile), there is no CISA KEV listing and no public exploit identified at time of analysis, so exploitation is not currently probable or observed. The residual risk is driven less by mass-exploitation likelihood and more by the device class: these are ICS/OT smart-grid data concentrators where any authenticated OS command execution is high-consequence. Note a signal tension worth flagging: the CVSS 4.0 UI:A (interaction required) is questionable for a classic self-service command-injection where an authenticated operator submits the payload directly into a diagnostic function they themselves invoke - verify with the INCIBE advisory whether a second user is genuinely in the loop. |
| Exploit ScenarioDerived | An attacker with low-privilege authenticated access to the SGE-PLC1000/SGE-PLC50 web/management interface enters shell metacharacters into the DNS, ping, or traceroute diagnostic input (GetDNS/CheckPing/TraceRoute), which are passed unsanitized to an OS shell, executing arbitrary commands on the device. No public proof-of-concept was identified at time of analysis; exploitation follows a well-understood diagnostic-function command-injection pattern. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv2 – Sep 26, 2026
Authenticated command injection in Circutor SGE-PLC1000 and SGE-PLC50 gateways running firmware 9.0.2 lets a low-privilege user of the management interface run arbitrary operating-system commands through the GetDNS(), CheckPing() and TraceRoute() diagnostic functions, which pass unsanitized input to the underlying shell. The vendor scores this 8.5 under CVSS 4.0 with PR:L and UI:A, and our independent CVSS 3.1 assessment agrees on high confidentiality, integrity and availability impact while emphasizing that exploitation is gated behind a valid authenticated session and the ICS deployment context. EPSS is low at 0.29% (52nd percentile), the CVE is not in CISA KEV, and no public exploit code was identified at time of analysis, so this is a genuine but access-gated flaw rather than an internet-exposed, unauthenticated remote compromise.
Earlier versions of this analysis (1)
RemediationAI
No patched firmware version is identified in the available data, so remediation should begin by consulting the Circutor/INCIBE advisory at https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0 for an updated firmware release and applying it as soon as Circutor publishes one. Until a fixed build is available, compensating controls are necessary: place the management interface of the SGE-PLC1000/SGE-PLC50 on a dedicated, tightly firewalled OT management VLAN and block HTTP/HTTPS access from user, corporate IT and internet-facing networks, accepting the trade-off that remote administration must be performed from a jump host inside the trusted segment; restrict and audit all accounts that can reach the diagnostics pages, since even low-privilege authenticated users can exploit this flaw, and remove or disable unused accounts to reduce the attack surface; if the diagnostic pages are not operationally required, restrict access to them or disable the affected GetDNS/CheckPing/TraceRoute functionality where the firmware allows it, with the trade-off of losing built-in network troubleshooting and possibly requiring alternative diagnostic tooling; and monitor device logs and network traffic for shell metacharacter patterns or unexpected outbound connections from the gateway as a detection measure. Because the vulnerability is not in CISA KEV and no public exploit has been observed, these steps should be prioritized according to the exposure of the management interface and the criticality of the affected energy-sector process.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This is a classic OS command injection (CWE-78, improper neutralization of special elements used in an OS command) in the firmware's network diagnostic tooling. The CPE strings cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2 and cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2 identify the affected code base, and the vulnerable functions GetDNS(), CheckPing() and TraceRoute() are the diagnostic wrappers that most likely shell out to utilities such as nslookup, ping and traceroute without sanitizing user-supplied hostnames or addresses, allowing shell metacharacters to be interpreted by the OS. The vendor's CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:A, with VC:H/VI:H/VA:H but SC:N/SI:N/SA:N) shows high impact confined to the device itself rather than a subsequent-system blast radius, and our independent CVSS 3.1 assessment (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) reaches a similar high-severity conclusion. Because these are power-line communication gateways used in energy/ICS environments, the practical reachability of the management interface depends heavily on network segmentation between IT and OT zones.
Know when Sge Plc1000 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Network-reachable diagnostic feature requiring a low-privilege authenticated session (PR:L); attacker submits their own injection so UI:N, and OS command execution gives full C/I/A on the device.
Primary rating from Vendor (incibe).
CVSS VectorVendor: incibe
Lifecycle Timeline
3DescriptionCVE.org
Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the 'GetDNS()', 'CheckPing()' and 'TraceRoute()' functions.
Executive ViewAI
A critical command injection vulnerability affects Circutor SGE-PLC1000/SGE-PLC50 devices running version 9.0.2, allowing attackers to execute arbitrary commands on affected industrial control systems. Organizations using these programmable logic controllers face immediate risk of system compromise, operational disruption, and potential safety incidents until a vendor patch becomes available.
Implement network segmentation and restrict access to affected devices using firewall rules and VLANs; disable or restrict the vulnerable functions (GetDNS, CheckPing, TraceRoute) at the application level if possible; monitor network traffic to these devices for suspicious command patterns; implement strict input validation at any interface communicating with these PLCs; establish 24/7 monitoring for indicators of compromise; prepare incident response procedures for potential exploitation.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
More in Sge Plc1000 Firmware
View allStack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' functi
Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function,
SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker
Stack-based buffer overflow in the Circutor SGE-PLC1000 and SGE-PLC50 power line communication devices running firmware
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an
Hardcoded cryptographic key exposure in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 lets an attacker who has loca
A stack-based buffer overflow in the AddEvent() function of Circutor SGE-PLC1000 and SGE-PLC50 power-line communication
Authenticated adjacent-network attackers can execute arbitrary shell commands on Circutor SGE-PLC1000 and SGE-PLC50 devi
Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 smart-grid PLC concentrators running firmware v9.0.2 a
Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 allows authenticated attackers on an a
Heap-based buffer overflow in the management interface of Circutor SGE-PLC1000 and SGE-PLC50 concentrators running firmw
EUVD-2025-200229
NVD
CVE.org
EPSS
VulDB
GitHub PoC
Exploit-DB