Authentication bypass in Schneider Electric Modicon M580 and Modicon M580 Safety PLCs stems from an incorrectly implemented authentication algorithm (CWE-303) that can be abused when an application project built at a lower application level is running on the controller. Remote attackers can compromise the confidentiality, integrity, and availability of the PLC, per the vendor's CVSS 4.0 base score of 9.2. No public exploit has been identified at time of analysis and the issue is not listed in CISA KEV.
Privilege escalation to root in Schneider Electric PowerLogic T300 (versions 2.9.8-5620 and prior) is achievable by an authenticated SSH user through OS command injection in the device's operating system console. An attacker with high-privilege SSH access can inject shell metacharacters into user-controlled console input that the device fails to properly sanitize, breaking out of the intended command context to execute arbitrary commands as root and perform unauthorized administrative operations. No public exploit code or CISA KEV listing has been identified at time of analysis; the CVSS 4.0 score of 8.7 reflects subsequent-system impact rated High, consistent with the device's ICS/energy-metering deployment context.
Server-Side Request Forgery in Schneider Electric EcoStruxure IT Data Center Expert (formerly StruxureWare Data Center Expert) versions 9.1.2 and prior enables a privileged authenticated attacker to send crafted, unvalidated parameters to a server endpoint, causing the platform to make unauthorized outbound or internal requests. The resulting impact spans unauthorized command execution and disclosure of server-side data - a unusually severe outcome for SSRF, likely achieved by pivoting through the SSRF to reach privileged internal services. No public exploit has been identified at time of analysis, and the vulnerability is not listed in CISA KEV.
Remote code execution is possible in Schneider Electric EcoStruxure IT Data Center Expert (formerly StruxureWare Data Center Expert) versions 9.1.2 and prior via an argument injection flaw (CWE-88) in backup configuration parameter handling. An attacker holding a privileged account can supply crafted arguments that are passed unsanitized to an underlying backup command, resulting in arbitrary OS-level code execution on the server. No public exploit code or active exploitation has been identified at time of analysis, but the network-reachable attack vector and full CIA impact make this a meaningful risk for any organization operating this data center infrastructure management platform.
OS command injection in Schneider Electric NetBotz 5 (models 750 and 755) environmental monitoring appliances allows arbitrary Linux OS command execution when a system backup that has been maliciously modified is restored on the device. Exploitation requires high-privilege administrative access and adjacent network positioning, substantially narrowing the realistic threat population to insiders or supply-chain compromise scenarios. No public exploit code has been identified at time of analysis, and the vulnerability is not listed in CISA KEV.
Local privilege escalation and authentication bypass in Schneider Electric EcoStruxure Cybersecurity Admin Expert allows a local, high-privileged attacker to abuse weak protection of stored credentials (CWE-522) to modify credentials without authorization and bypass authentication, potentially pivoting to compromise the OT/industrial devices the tool manages. Schneider Electric published security notice SEVD-2026-195-02, and the CVSS 4.0 base score is 8.7 (High) with a scope change into subsequent systems. There is no public exploit identified at time of analysis and it is not listed in CISA KEV.
Authenticated command injection in Schneider Electric PowerLogic P7 power metering devices allows a privileged user to execute arbitrary OS commands with elevated privileges over a network-exposed service, fully compromising device integrity, confidentiality, and availability. The flaw (CWE-78) stems from improper neutralization of special elements passed to an underlying OS command. No public exploit identified at time of analysis, and the device is not listed in CISA KEV; EPSS data was not provided.
Denial-of-service in Schneider Electric PowerLogic P7 power metering devices allows remote, unauthenticated attackers to crash the device's HMI and configuration functionality by sending malformed requests to exposed network interfaces. The flaw stems from a NULL pointer dereference (CWE-476) that renders local management and configuration unavailable until recovery. No public exploit identified at time of analysis, and the issue is not listed in CISA KEV; the CVSS 4.0 base score of 8.7 reflects a high availability impact with no confidentiality or integrity exposure.
Credential exposure in Schneider Electric EasyLogic T150 (formerly Saitel DR) and Saitel DP Remote Terminal Units & Controllers allows an unauthenticated attacker to recover credentials that are insufficiently protected within device firmware or system files (CWE-522). The recovered credentials can then be used to fully compromise the device when the attacker also has physical access. No public exploit identified at time of analysis and the issue is not listed in CISA KEV; vendor advisory SEVD-2026-160-02 covers the affected OT products.
Server-side file disclosure in Schneider Electric EcoStruxure IT Data Center Expert v9.1.1 and prior allows authenticated users to read arbitrary files on the underlying host by submitting crafted XML payloads to SOAP service endpoints. The flaw stems from improper restriction of XML External Entity references (CWE-611) in the SOAP API. No public exploit identified at time of analysis, but CISA SSVC marks the issue as automatable with partial technical impact.
Schneider Electric EcoStruxure Panel Server can revert credentials to insecure default values under rare circumstances, allowing remote unauthenticated attackers to gain unauthorized access using known factory credentials. This CWE-1188 vulnerability enables complete confidential information disclosure (CVSS 8.2 High). Exploitation requires specific timing conditions (AT:P - Attack Timing: Present) to catch the window when credentials reset. EPSS data not available; no CISA KEV listing or public POC identified at time of analysis, suggesting targeted rather than widespread exploitation risk.
Unauthorized file disclosure in Schneider Electric Saitel DP and EasyLogic T150 (formerly Saitel DR) Remote Terminal Units lets a low-privileged remote attacker read sensitive files outside intended directories via improper server-side file path handling. The advisory tagging also associates the flaw with an authentication-bypass angle, and the primary impact is confidentiality of files on the affected OT/ICS controllers. There is no public exploit identified at time of analysis, EPSS risk is very low (0.06%, 17th percentile), and CISA SSVC rates exploitation as none.
Weak session token generation in Schneider Electric industrial protection relays and energy management systems allows remote attackers to hijack authenticated user sessions via network-based prediction attacks. Affects 36 product variants across Easergy MiCOM P30/P40/C264, PowerLogic P5/P7/T-series, EcoStruxure Power Automation/Operation platforms, and iPMFLS systems. CVSS 8.7 reflects high confidentiality and integrity impact with user interaction required. No active exploitation confirmed (not in CISA KEV), but authentication bypass via session prediction enables privilege escalation in critical infrastructure environments. EPSS data not provided - risk assessment relies on CVSS vector and operational technology context.
Code injection (CWE-94) in Schneider Electric EcoStruxure Automation Expert allows an authenticated user who opens a malicious project file to execute untrusted commands on the engineering workstation, resulting in limited compromise and potential loss of confidentiality, integrity, and availability of subsequent systems. Exploitation requires local access, low-level privileges, and victim interaction (opening the crafted file), so it is a social-engineering-driven local RCE rather than a remote network attack. There is no public exploit identified at time of analysis and the EPSS score is very low (0.02%, 6th percentile), indicating minimal expectation of widespread exploitation.
Remote code execution in Schneider Electric EcoStruxure Foxboro DCS Control Software allows a locally authenticated administrator to compromise the engineering workstation by opening a maliciously crafted project file, which triggers unsafe deserialization (CWE-502) leading to loss of confidentiality, integrity, and availability. The flaw affects operators of Foxboro distributed control systems and requires the victim to open the attacker-supplied file. There is no public exploit identified at time of analysis, and EPSS estimates only a 0.22% 30-day exploitation probability, consistent with a high-privilege, local, user-interaction-dependent issue rather than a mass-exploitable one.
A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Credential interception vulnerability in Schneider Electric SCADAPack RTUs (Remote Terminal Units) exposes authentication information over the network, enabling unauthorized access to RTU functionality. Affected products span the SCADAPack 3xx, 32, 47x/470R, and 57x families - all version ranges per CPE wildcards - used extensively in critical infrastructure sectors such as oil and gas pipelines, water systems, and electrical utilities. No public exploit code or active exploitation (CISA KEV) has been identified at time of analysis, but successful exploitation yields full credential disclosure and subsequent unauthorized control of industrial RTU assets.
Unrestricted authentication attempts against Schneider Electric PowerChute™ Serial Shutdown expose user accounts to brute-force compromise when redirect handling is disabled in the application configuration. The absence of any rate-limiting or account-lockout mechanism (CWE-307) allows an attacker to submit unlimited credential-guessing requests over the network until valid credentials are found. No public exploit code has been identified at time of analysis, and this CVE does not appear in the CISA KEV catalog.
HQL injection in Schneider Electric NetBotz 5 models 750 and 755 allows an authenticated attacker on the same adjacent network segment to inject malicious Hibernate Query Language statements through the appliance's web service interface or web UI, gaining limited unauthorized read and write access to the NetBotz database. The CVSS 4.0 score of 5.1 reflects a constrained attack surface - both network adjacency and a valid low-privilege account are prerequisites. No public exploit has been identified at time of analysis, and the vulnerability is not listed in the CISA KEV catalog.
Denial-of-service in Schneider Electric PowerLogic P7 power monitoring devices allows an authenticated attacker to crash a network-exposed service by sending a specially crafted request that triggers a reachable assertion (CWE-617), fully disrupting availability. The CVSS 4.0 score of 6.9 reflects the high-privilege prerequisite (PR:H) that constrains exploitation to actors with administrative credentials, while the availability impact is rated high (VA:H) with no confidentiality or integrity consequences. No public exploit code and no active exploitation via CISA KEV have been identified at time of analysis.
Incorrect file permission assignment on Schneider Electric EasyLogic T150 (formerly Saitel DR) and Saitel DP Remote Terminal Units exposes password hashes stored in system files to unauthorized reading by privileged local users. An attacker who has already obtained privileged local access to the RTU can read these improperly protected files, extract credential hashes, and perform offline cracking to achieve account compromise. No public exploit code exists at time of analysis, and the vulnerability has not been listed in CISA KEV, but the high confidentiality impact on credential material in OT/ICS environments warrants attention.
Source code disclosure vulnerability in Schneider Electric EcoStruxure Machine Expert HVAC versions prior to 1.10.0 allows authorized users with local access to view protected source code stored in cleartext, resulting in loss of confidentiality and potential exposure of proprietary logic. The vulnerability requires local authenticated access and is rooted in improper protection of sensitive information at rest; no active exploitation or public exploit code has been identified.
Schneider Electric PowerChute™ Serial Shutdown versions 1.4 and prior expose confidential information through log file insertion when a Web Admin user executes a malicious file supplied by an attacker. The vulnerability (CWE-532) results in low confidentiality impact with local access required and user interaction; no public exploit code or active exploitation has been identified, and the overall CVSS score of 2.4 reflects limited real-world risk despite information disclosure classification.
CRLF injection in Schneider Electric PowerChute™ Serial Shutdown versions 1.4 and prior allows authenticated Web Admin users to reset application user credentials by manipulating the POST /setPCBEDesc request payload, achieving limited availability impact with CVSS 5.3 and confirmed actively exploited status (CISA KEV).
Improper validation of input quantity in Schneider Electric PowerChute Serial Shutdown versions 1.4 and prior allows authenticated Web Admin users to truncate event and data logs via crafted POST /logsettings requests, compromising log integrity and audit trail reliability. The vulnerability requires valid admin credentials and network access but poses direct impact to forensic and compliance capabilities. No public exploit code or active exploitation has been confirmed at time of analysis.
Denial of service in Schneider Electric PowerChute Serial Shutdown versions 1.4 and prior allows authenticated Web Admin users to trigger uncontrolled resource consumption by flooding the system with POST requests to the /helpabout endpoint, causing excessive troubleshooting zip file creation and service degradation. Attack requires valid admin credentials and network access to the web interface; CVSS 5.3 reflects low availability impact with no confidentiality or integrity compromise.
Schneider Electric PowerChute Serial Shutdown v1.4 and prior allows remote credential brute force attacks due to missing rate limiting on authentication endpoints, enabling attackers to enumerate valid credentials across multiple API endpoints with no authentication prerequisite. The vulnerability has a CVSS score of 6.9 with network-based attack vector and no user interaction required, though the impact is limited to information disclosure rather than full account takeover.
Log injection via improper output encoding in Schneider Electric PowerChute™ Serial Shutdown allows unauthenticated remote attackers to forge or inject malicious log entries by sending crafted POST requests to the /j_security_check endpoint, potentially obscuring attack trails or triggering false alerts.
PowerChute Serial Shutdown allows authenticated administrative users to overwrite critical system files via path traversal in the POST /REST/upssleep endpoint when maliciously crafting request payloads, potentially causing complete system compromise or denial of service. The vulnerability requires high-privilege Web Admin credentials and adjacent network access, but results in total integrity and availability impact across the affected system. No public exploit code has been identified at the time of analysis.
Schneider Electric Easergy MiCOM protective relays contain hard-coded SNMP credentials that allow unauthenticated remote attackers to access sensitive device information and system configurations. An attacker can directly query the SNMP port (UDP 161) without authentication to retrieve operational data, relay status, and device parameters. This vulnerability affects 12 product lines across multiple versions and is classified as an authentication bypass with a CVSS 6.9 (medium-to-high confidentiality impact).
Cross-site scripting in Schneider Electric Modicon PLC embedded web servers (M258, LMC058, M251, M241) allows authenticated low-privilege attackers to inject persistent JavaScript payloads that execute in a victim engineer's browser upon hovering over a crafted element. In industrial OT environments, successful exploitation could compromise engineering workstation sessions, steal credentials used to configure programmable logic controllers, or manipulate displayed process data. No public exploit code exists and the CVE is absent from CISA KEV; EPSS at 0.05% (14th percentile) confirms low current exploitation likelihood, though the ICS context elevates operational consequence beyond what raw scores suggest.
Partial Denial of Service against Schneider Electric Modicon M241, M251, and M262 programmable logic controllers (PLCs) is achievable by unauthenticated remote attackers via the Machine Expert programming protocol. Exploitation requires only network reachability to the affected PLC - no credentials or user interaction - allowing an attacker to send malformed payloads that exhaust active communication channels through improper resource release (CWE-404). No public exploit code exists and EPSS is very low (0.05%), but the network-accessible attack surface with zero authentication in OT environments elevates operational risk beyond the Medium CVSS rating suggests.
Arbitrary code execution with administrative privileges in Schneider Electric EcoStruxure Power Monitoring Expert (2022 through 2024 R2) and EcoStruxure Power Operation (2022, 2024) allows a locally authenticated attacker to run code by sending a crafted data stream that triggers unsafe object deserialization (CWE-502). Authentication is required (CVSS 4.0 PR:L) and the vector is local, but successful exploitation fully compromises the host with high confidentiality, integrity, and availability impact. There is no public exploit identified at time of analysis, and the EPSS probability is very low (0.07%, 20th percentile).
Arbitrary code execution in Schneider Electric EcoStruxure Power Build - Rapsody occurs when a user imports a maliciously crafted SSD project file, triggering a use-after-free condition (CWE-416) that yields full confidentiality, integrity and availability impact on the engineering workstation. Exploitation requires the victim to actively open the attacker-supplied file, so it is a client-side/local vector rather than a remotely reachable service. There is no public exploit identified at time of analysis and EPSS probability is very low (0.02%), consistent with a targeted social-engineering delivery rather than mass exploitation.
Heap memory corruption via double free in Schneider Electric's EcoStruxure Power Build - Rapsody enables arbitrary code execution when an engineer imports a crafted SSD project file delivered by an attacker. The vulnerability spans all localized editions of the software (French, Belgian Dutch, Spanish, International, and Belgian French) with no upper version bound confirmed in NVD CPE data. No public exploit has been identified and no CISA KEV listing exists; however, the file-based social engineering delivery path is realistic and well-suited to targeted attacks against industrial design personnel.
unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Uncontrolled Resource Consumption vulnerability could allow attackers to cause denial of service by exhausting system resources.
the network and potentially impacting connected devices. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Missing Authorization vulnerability could allow attackers to access resources or perform actions without proper authorization checks.
of service and loss of confidentiality & integrity when application user opens a malicious Zelio Soft 2 project file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
access, loss of confidentiality, integrity and availability of the workstation when non-admin authenticated user tries to perform privilege escalation by tampering with the binaries. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
credentials when a specially crafted message is sent to the device. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
privilege escalation, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
call in the Foxboro.sys driver. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. No vendor patch available.
kernel memory leak when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver. Rated high severity (CVSS 7.1), this vulnerability is low attack complexity. No vendor patch available.
Traversal') vulnerability exists that could result in remote code execution when an authenticated user executes a saved project file that has been tampered by a malicious actor. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
cause denial of service, device reboot, or an attacker gaining full control of the relay when a specially crafted reset token is entered into the front panel of the device. Rated medium severity (CVSS 6.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
cause privilege escalation when a valid user replaces a trusted file name on the system and reboots the machine. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
escalation when logged in as a non-administrative user. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
device’s web interface when an attacker sends a specially crafted HTTP request. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Out-of-bounds Read vulnerability could allow attackers to read data from memory outside the intended buffer boundaries.
cause escalation of privileges when an attacker abuses a limited admin account. Rated medium severity (CVSS 6.4).
exposure of SNMP credentials when an attacker has access to the controller logs. Rated medium severity (CVSS 4.5), this vulnerability is low attack complexity.
exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request. Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, low attack complexity. This Buffer Copy without Size Check vulnerability could allow attackers to overflow a buffer to corrupt adjacent memory.
device when an attacker sends a specially crafted HTTP request. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity.
user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. This Incorrect Default Permissions vulnerability could allow attackers to access resources due to overly permissive default settings.
Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request. Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, low attack complexity. This Path Traversal vulnerability could allow attackers to access files and directories outside the intended path.
when sending a malformed POST request and particular configuration parameters are set. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
interface over the product network interface. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
prevent user to update the device firmware and prevent proper behavior of the webserver when specific files or directories are removed from the filesystem. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker logged in with a user level account to gain higher privileges by providing a harmful serialized object. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local. Rated high severity (CVSS 7.1), this vulnerability is low attack complexity. No vendor patch available.
A CWE-494: Download of Code Without Integrity Check vulnerability exists that could allow a privileged user to install an untrusted firmware. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-601:URL Redirection to Untrusted Site (‘Open Redirect’) vulnerability exists that could cause disclosure of information through phishing attempts over HTTP. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause a file system enumeration and file download when an attacker navigates. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Cross-Site Scripting (XSS) vulnerability could allow attackers to inject malicious scripts into web pages viewed by other users.
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability exists that could cause compromise of a user’s browser when an attacker with admin privileges has modified system. Rated medium severity (CVSS 4.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-494 Download of Code Without Integrity Check vulnerability exists that could allow modified firmware to be uploaded when an authorized admin user begins a firmware update procedure which could. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote code execution when the transfer command is used over the network. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update Service that could allow a local attacker to change update source, potentially leading to remote code. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity.
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause memory corruption when an authenticated user opens a tampered log file from. Rated medium severity (CVSS 5.3), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
A CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability exists that could cause user privilege escalation if a local user sends specific string input to a local. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. This Buffer Copy without Size Check vulnerability could allow attackers to overflow a buffer to corrupt adjacent memory.
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE tampers with backups which are then manually. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE uploads or tampers with install packages. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
A CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service, and potentially kernel execution when a malicious actor with local user access crafts a. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
A CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, elevation of privilege, and potentially kernel execution when a malicious actor with local user access. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. No vendor patch available.
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity.
A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity.
Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This OS Command Injection vulnerability could allow attackers to execute arbitrary operating system commands on the host.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity.
A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain unauthorized access over a hijacked session in PME after the legitimate user has signed out of. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Authentication bypass in Schneider Electric Modicon M580 and Modicon M580 Safety PLCs stems from an incorrectly implemented authentication algorithm (CWE-303) that can be abused when an application project built at a lower application level is running on the controller. Remote attackers can compromise the confidentiality, integrity, and availability of the PLC, per the vendor's CVSS 4.0 base score of 9.2. No public exploit has been identified at time of analysis and the issue is not listed in CISA KEV.
Privilege escalation to root in Schneider Electric PowerLogic T300 (versions 2.9.8-5620 and prior) is achievable by an authenticated SSH user through OS command injection in the device's operating system console. An attacker with high-privilege SSH access can inject shell metacharacters into user-controlled console input that the device fails to properly sanitize, breaking out of the intended command context to execute arbitrary commands as root and perform unauthorized administrative operations. No public exploit code or CISA KEV listing has been identified at time of analysis; the CVSS 4.0 score of 8.7 reflects subsequent-system impact rated High, consistent with the device's ICS/energy-metering deployment context.
Server-Side Request Forgery in Schneider Electric EcoStruxure IT Data Center Expert (formerly StruxureWare Data Center Expert) versions 9.1.2 and prior enables a privileged authenticated attacker to send crafted, unvalidated parameters to a server endpoint, causing the platform to make unauthorized outbound or internal requests. The resulting impact spans unauthorized command execution and disclosure of server-side data - a unusually severe outcome for SSRF, likely achieved by pivoting through the SSRF to reach privileged internal services. No public exploit has been identified at time of analysis, and the vulnerability is not listed in CISA KEV.
Remote code execution is possible in Schneider Electric EcoStruxure IT Data Center Expert (formerly StruxureWare Data Center Expert) versions 9.1.2 and prior via an argument injection flaw (CWE-88) in backup configuration parameter handling. An attacker holding a privileged account can supply crafted arguments that are passed unsanitized to an underlying backup command, resulting in arbitrary OS-level code execution on the server. No public exploit code or active exploitation has been identified at time of analysis, but the network-reachable attack vector and full CIA impact make this a meaningful risk for any organization operating this data center infrastructure management platform.
OS command injection in Schneider Electric NetBotz 5 (models 750 and 755) environmental monitoring appliances allows arbitrary Linux OS command execution when a system backup that has been maliciously modified is restored on the device. Exploitation requires high-privilege administrative access and adjacent network positioning, substantially narrowing the realistic threat population to insiders or supply-chain compromise scenarios. No public exploit code has been identified at time of analysis, and the vulnerability is not listed in CISA KEV.
Local privilege escalation and authentication bypass in Schneider Electric EcoStruxure Cybersecurity Admin Expert allows a local, high-privileged attacker to abuse weak protection of stored credentials (CWE-522) to modify credentials without authorization and bypass authentication, potentially pivoting to compromise the OT/industrial devices the tool manages. Schneider Electric published security notice SEVD-2026-195-02, and the CVSS 4.0 base score is 8.7 (High) with a scope change into subsequent systems. There is no public exploit identified at time of analysis and it is not listed in CISA KEV.
Authenticated command injection in Schneider Electric PowerLogic P7 power metering devices allows a privileged user to execute arbitrary OS commands with elevated privileges over a network-exposed service, fully compromising device integrity, confidentiality, and availability. The flaw (CWE-78) stems from improper neutralization of special elements passed to an underlying OS command. No public exploit identified at time of analysis, and the device is not listed in CISA KEV; EPSS data was not provided.
Denial-of-service in Schneider Electric PowerLogic P7 power metering devices allows remote, unauthenticated attackers to crash the device's HMI and configuration functionality by sending malformed requests to exposed network interfaces. The flaw stems from a NULL pointer dereference (CWE-476) that renders local management and configuration unavailable until recovery. No public exploit identified at time of analysis, and the issue is not listed in CISA KEV; the CVSS 4.0 base score of 8.7 reflects a high availability impact with no confidentiality or integrity exposure.
Credential exposure in Schneider Electric EasyLogic T150 (formerly Saitel DR) and Saitel DP Remote Terminal Units & Controllers allows an unauthenticated attacker to recover credentials that are insufficiently protected within device firmware or system files (CWE-522). The recovered credentials can then be used to fully compromise the device when the attacker also has physical access. No public exploit identified at time of analysis and the issue is not listed in CISA KEV; vendor advisory SEVD-2026-160-02 covers the affected OT products.
Server-side file disclosure in Schneider Electric EcoStruxure IT Data Center Expert v9.1.1 and prior allows authenticated users to read arbitrary files on the underlying host by submitting crafted XML payloads to SOAP service endpoints. The flaw stems from improper restriction of XML External Entity references (CWE-611) in the SOAP API. No public exploit identified at time of analysis, but CISA SSVC marks the issue as automatable with partial technical impact.
Schneider Electric EcoStruxure Panel Server can revert credentials to insecure default values under rare circumstances, allowing remote unauthenticated attackers to gain unauthorized access using known factory credentials. This CWE-1188 vulnerability enables complete confidential information disclosure (CVSS 8.2 High). Exploitation requires specific timing conditions (AT:P - Attack Timing: Present) to catch the window when credentials reset. EPSS data not available; no CISA KEV listing or public POC identified at time of analysis, suggesting targeted rather than widespread exploitation risk.
Unauthorized file disclosure in Schneider Electric Saitel DP and EasyLogic T150 (formerly Saitel DR) Remote Terminal Units lets a low-privileged remote attacker read sensitive files outside intended directories via improper server-side file path handling. The advisory tagging also associates the flaw with an authentication-bypass angle, and the primary impact is confidentiality of files on the affected OT/ICS controllers. There is no public exploit identified at time of analysis, EPSS risk is very low (0.06%, 17th percentile), and CISA SSVC rates exploitation as none.
Weak session token generation in Schneider Electric industrial protection relays and energy management systems allows remote attackers to hijack authenticated user sessions via network-based prediction attacks. Affects 36 product variants across Easergy MiCOM P30/P40/C264, PowerLogic P5/P7/T-series, EcoStruxure Power Automation/Operation platforms, and iPMFLS systems. CVSS 8.7 reflects high confidentiality and integrity impact with user interaction required. No active exploitation confirmed (not in CISA KEV), but authentication bypass via session prediction enables privilege escalation in critical infrastructure environments. EPSS data not provided - risk assessment relies on CVSS vector and operational technology context.
Code injection (CWE-94) in Schneider Electric EcoStruxure Automation Expert allows an authenticated user who opens a malicious project file to execute untrusted commands on the engineering workstation, resulting in limited compromise and potential loss of confidentiality, integrity, and availability of subsequent systems. Exploitation requires local access, low-level privileges, and victim interaction (opening the crafted file), so it is a social-engineering-driven local RCE rather than a remote network attack. There is no public exploit identified at time of analysis and the EPSS score is very low (0.02%, 6th percentile), indicating minimal expectation of widespread exploitation.
Remote code execution in Schneider Electric EcoStruxure Foxboro DCS Control Software allows a locally authenticated administrator to compromise the engineering workstation by opening a maliciously crafted project file, which triggers unsafe deserialization (CWE-502) leading to loss of confidentiality, integrity, and availability. The flaw affects operators of Foxboro distributed control systems and requires the victim to open the attacker-supplied file. There is no public exploit identified at time of analysis, and EPSS estimates only a 0.22% 30-day exploitation probability, consistent with a high-privilege, local, user-interaction-dependent issue rather than a mass-exploitable one.
A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Credential interception vulnerability in Schneider Electric SCADAPack RTUs (Remote Terminal Units) exposes authentication information over the network, enabling unauthorized access to RTU functionality. Affected products span the SCADAPack 3xx, 32, 47x/470R, and 57x families - all version ranges per CPE wildcards - used extensively in critical infrastructure sectors such as oil and gas pipelines, water systems, and electrical utilities. No public exploit code or active exploitation (CISA KEV) has been identified at time of analysis, but successful exploitation yields full credential disclosure and subsequent unauthorized control of industrial RTU assets.
Unrestricted authentication attempts against Schneider Electric PowerChute™ Serial Shutdown expose user accounts to brute-force compromise when redirect handling is disabled in the application configuration. The absence of any rate-limiting or account-lockout mechanism (CWE-307) allows an attacker to submit unlimited credential-guessing requests over the network until valid credentials are found. No public exploit code has been identified at time of analysis, and this CVE does not appear in the CISA KEV catalog.
HQL injection in Schneider Electric NetBotz 5 models 750 and 755 allows an authenticated attacker on the same adjacent network segment to inject malicious Hibernate Query Language statements through the appliance's web service interface or web UI, gaining limited unauthorized read and write access to the NetBotz database. The CVSS 4.0 score of 5.1 reflects a constrained attack surface - both network adjacency and a valid low-privilege account are prerequisites. No public exploit has been identified at time of analysis, and the vulnerability is not listed in the CISA KEV catalog.
Denial-of-service in Schneider Electric PowerLogic P7 power monitoring devices allows an authenticated attacker to crash a network-exposed service by sending a specially crafted request that triggers a reachable assertion (CWE-617), fully disrupting availability. The CVSS 4.0 score of 6.9 reflects the high-privilege prerequisite (PR:H) that constrains exploitation to actors with administrative credentials, while the availability impact is rated high (VA:H) with no confidentiality or integrity consequences. No public exploit code and no active exploitation via CISA KEV have been identified at time of analysis.
Incorrect file permission assignment on Schneider Electric EasyLogic T150 (formerly Saitel DR) and Saitel DP Remote Terminal Units exposes password hashes stored in system files to unauthorized reading by privileged local users. An attacker who has already obtained privileged local access to the RTU can read these improperly protected files, extract credential hashes, and perform offline cracking to achieve account compromise. No public exploit code exists at time of analysis, and the vulnerability has not been listed in CISA KEV, but the high confidentiality impact on credential material in OT/ICS environments warrants attention.
Source code disclosure vulnerability in Schneider Electric EcoStruxure Machine Expert HVAC versions prior to 1.10.0 allows authorized users with local access to view protected source code stored in cleartext, resulting in loss of confidentiality and potential exposure of proprietary logic. The vulnerability requires local authenticated access and is rooted in improper protection of sensitive information at rest; no active exploitation or public exploit code has been identified.
Schneider Electric PowerChute™ Serial Shutdown versions 1.4 and prior expose confidential information through log file insertion when a Web Admin user executes a malicious file supplied by an attacker. The vulnerability (CWE-532) results in low confidentiality impact with local access required and user interaction; no public exploit code or active exploitation has been identified, and the overall CVSS score of 2.4 reflects limited real-world risk despite information disclosure classification.
CRLF injection in Schneider Electric PowerChute™ Serial Shutdown versions 1.4 and prior allows authenticated Web Admin users to reset application user credentials by manipulating the POST /setPCBEDesc request payload, achieving limited availability impact with CVSS 5.3 and confirmed actively exploited status (CISA KEV).
Improper validation of input quantity in Schneider Electric PowerChute Serial Shutdown versions 1.4 and prior allows authenticated Web Admin users to truncate event and data logs via crafted POST /logsettings requests, compromising log integrity and audit trail reliability. The vulnerability requires valid admin credentials and network access but poses direct impact to forensic and compliance capabilities. No public exploit code or active exploitation has been confirmed at time of analysis.
Denial of service in Schneider Electric PowerChute Serial Shutdown versions 1.4 and prior allows authenticated Web Admin users to trigger uncontrolled resource consumption by flooding the system with POST requests to the /helpabout endpoint, causing excessive troubleshooting zip file creation and service degradation. Attack requires valid admin credentials and network access to the web interface; CVSS 5.3 reflects low availability impact with no confidentiality or integrity compromise.
Schneider Electric PowerChute Serial Shutdown v1.4 and prior allows remote credential brute force attacks due to missing rate limiting on authentication endpoints, enabling attackers to enumerate valid credentials across multiple API endpoints with no authentication prerequisite. The vulnerability has a CVSS score of 6.9 with network-based attack vector and no user interaction required, though the impact is limited to information disclosure rather than full account takeover.
Log injection via improper output encoding in Schneider Electric PowerChute™ Serial Shutdown allows unauthenticated remote attackers to forge or inject malicious log entries by sending crafted POST requests to the /j_security_check endpoint, potentially obscuring attack trails or triggering false alerts.
PowerChute Serial Shutdown allows authenticated administrative users to overwrite critical system files via path traversal in the POST /REST/upssleep endpoint when maliciously crafting request payloads, potentially causing complete system compromise or denial of service. The vulnerability requires high-privilege Web Admin credentials and adjacent network access, but results in total integrity and availability impact across the affected system. No public exploit code has been identified at the time of analysis.
Schneider Electric Easergy MiCOM protective relays contain hard-coded SNMP credentials that allow unauthenticated remote attackers to access sensitive device information and system configurations. An attacker can directly query the SNMP port (UDP 161) without authentication to retrieve operational data, relay status, and device parameters. This vulnerability affects 12 product lines across multiple versions and is classified as an authentication bypass with a CVSS 6.9 (medium-to-high confidentiality impact).
Cross-site scripting in Schneider Electric Modicon PLC embedded web servers (M258, LMC058, M251, M241) allows authenticated low-privilege attackers to inject persistent JavaScript payloads that execute in a victim engineer's browser upon hovering over a crafted element. In industrial OT environments, successful exploitation could compromise engineering workstation sessions, steal credentials used to configure programmable logic controllers, or manipulate displayed process data. No public exploit code exists and the CVE is absent from CISA KEV; EPSS at 0.05% (14th percentile) confirms low current exploitation likelihood, though the ICS context elevates operational consequence beyond what raw scores suggest.
Partial Denial of Service against Schneider Electric Modicon M241, M251, and M262 programmable logic controllers (PLCs) is achievable by unauthenticated remote attackers via the Machine Expert programming protocol. Exploitation requires only network reachability to the affected PLC - no credentials or user interaction - allowing an attacker to send malformed payloads that exhaust active communication channels through improper resource release (CWE-404). No public exploit code exists and EPSS is very low (0.05%), but the network-accessible attack surface with zero authentication in OT environments elevates operational risk beyond the Medium CVSS rating suggests.
Arbitrary code execution with administrative privileges in Schneider Electric EcoStruxure Power Monitoring Expert (2022 through 2024 R2) and EcoStruxure Power Operation (2022, 2024) allows a locally authenticated attacker to run code by sending a crafted data stream that triggers unsafe object deserialization (CWE-502). Authentication is required (CVSS 4.0 PR:L) and the vector is local, but successful exploitation fully compromises the host with high confidentiality, integrity, and availability impact. There is no public exploit identified at time of analysis, and the EPSS probability is very low (0.07%, 20th percentile).
Arbitrary code execution in Schneider Electric EcoStruxure Power Build - Rapsody occurs when a user imports a maliciously crafted SSD project file, triggering a use-after-free condition (CWE-416) that yields full confidentiality, integrity and availability impact on the engineering workstation. Exploitation requires the victim to actively open the attacker-supplied file, so it is a client-side/local vector rather than a remotely reachable service. There is no public exploit identified at time of analysis and EPSS probability is very low (0.02%), consistent with a targeted social-engineering delivery rather than mass exploitation.
Heap memory corruption via double free in Schneider Electric's EcoStruxure Power Build - Rapsody enables arbitrary code execution when an engineer imports a crafted SSD project file delivered by an attacker. The vulnerability spans all localized editions of the software (French, Belgian Dutch, Spanish, International, and Belgian French) with no upper version bound confirmed in NVD CPE data. No public exploit has been identified and no CISA KEV listing exists; however, the file-based social engineering delivery path is realistic and well-suited to targeted attacks against industrial design personnel.
unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Uncontrolled Resource Consumption vulnerability could allow attackers to cause denial of service by exhausting system resources.
the network and potentially impacting connected devices. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Missing Authorization vulnerability could allow attackers to access resources or perform actions without proper authorization checks.
of service and loss of confidentiality & integrity when application user opens a malicious Zelio Soft 2 project file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
access, loss of confidentiality, integrity and availability of the workstation when non-admin authenticated user tries to perform privilege escalation by tampering with the binaries. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
credentials when a specially crafted message is sent to the device. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
privilege escalation, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
call in the Foxboro.sys driver. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. No vendor patch available.
kernel memory leak when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver. Rated high severity (CVSS 7.1), this vulnerability is low attack complexity. No vendor patch available.
Traversal') vulnerability exists that could result in remote code execution when an authenticated user executes a saved project file that has been tampered by a malicious actor. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
cause denial of service, device reboot, or an attacker gaining full control of the relay when a specially crafted reset token is entered into the front panel of the device. Rated medium severity (CVSS 6.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
cause privilege escalation when a valid user replaces a trusted file name on the system and reboots the machine. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
escalation when logged in as a non-administrative user. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
device’s web interface when an attacker sends a specially crafted HTTP request. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Out-of-bounds Read vulnerability could allow attackers to read data from memory outside the intended buffer boundaries.
cause escalation of privileges when an attacker abuses a limited admin account. Rated medium severity (CVSS 6.4).
exposure of SNMP credentials when an attacker has access to the controller logs. Rated medium severity (CVSS 4.5), this vulnerability is low attack complexity.
exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request. Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, low attack complexity. This Buffer Copy without Size Check vulnerability could allow attackers to overflow a buffer to corrupt adjacent memory.
device when an attacker sends a specially crafted HTTP request. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity.
user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. This Incorrect Default Permissions vulnerability could allow attackers to access resources due to overly permissive default settings.
Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request. Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, low attack complexity. This Path Traversal vulnerability could allow attackers to access files and directories outside the intended path.
when sending a malformed POST request and particular configuration parameters are set. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
interface over the product network interface. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
prevent user to update the device firmware and prevent proper behavior of the webserver when specific files or directories are removed from the filesystem. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker logged in with a user level account to gain higher privileges by providing a harmful serialized object. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local. Rated high severity (CVSS 7.1), this vulnerability is low attack complexity. No vendor patch available.
A CWE-494: Download of Code Without Integrity Check vulnerability exists that could allow a privileged user to install an untrusted firmware. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-601:URL Redirection to Untrusted Site (‘Open Redirect’) vulnerability exists that could cause disclosure of information through phishing attempts over HTTP. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause a file system enumeration and file download when an attacker navigates. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Cross-Site Scripting (XSS) vulnerability could allow attackers to inject malicious scripts into web pages viewed by other users.
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability exists that could cause compromise of a user’s browser when an attacker with admin privileges has modified system. Rated medium severity (CVSS 4.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-494 Download of Code Without Integrity Check vulnerability exists that could allow modified firmware to be uploaded when an authorized admin user begins a firmware update procedure which could. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote code execution when the transfer command is used over the network. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update Service that could allow a local attacker to change update source, potentially leading to remote code. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity.
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause memory corruption when an authenticated user opens a tampered log file from. Rated medium severity (CVSS 5.3), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
A CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability exists that could cause user privilege escalation if a local user sends specific string input to a local. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. This Buffer Copy without Size Check vulnerability could allow attackers to overflow a buffer to corrupt adjacent memory.
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE tampers with backups which are then manually. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE uploads or tampers with install packages. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
A CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service, and potentially kernel execution when a malicious actor with local user access crafts a. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
A CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, elevation of privilege, and potentially kernel execution when a malicious actor with local user access. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. No vendor patch available.
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity.
A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity.
Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This OS Command Injection vulnerability could allow attackers to execute arbitrary operating system commands on the host.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity.
A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain unauthorized access over a hijacked session in PME after the legitimate user has signed out of. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.