Skip to main content

Ecostruxure Power Operation CVE-2025-11739

HIGH
Deserialization of Untrusted Data (CWE-502)
2026-03-10 cybersecurity@se.com
8.5
CVSS 4.0 · Vendor: se
View

Vulnerability Assessment

Weakness
CWE
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Initial Access

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Act Now Prioritize within 24-48h. Why: Active threat signals + CRITICAL/HIGH severity.
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv2 – Jul 24, 2026

Arbitrary code execution with administrative privileges in Schneider Electric EcoStruxure Power Monitoring Expert (2022 through 2024 R2) and EcoStruxure Power Operation (2022, 2024) allows a locally authenticated attacker to run code by sending a crafted data stream that triggers unsafe object deserialization (CWE-502). Authentication is required (CVSS 4.0 PR:L) and the vector is local, but successful exploitation fully compromises the host with high confidentiality, integrity, and availability impact. There is no public exploit identified at time of analysis, and the EPSS probability is very low (0.07%, 20th percentile).

Earlier versions of this analysis (1)
v1 Mar 12, 2026 - 21:55

CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Know when Ecostruxure Power Operation gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (se) PRIMARY 8.5 HIGH
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (se) · only source for this CVE.

CVSS VectorVendor: se

Attack Vector
Local
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

3
CVSS changed
Jun 24, 2026 - 19:22 NVD
8.5 (HIGH)
CVE Published
Mar 10, 2026 - 18:17 nvd
N/A
CVE Published
Mar 10, 2026 - 18:17 cve.org
HIGH 8.5

DescriptionCVE.org

CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.

Executive ViewAI

Why It Matters

Schneider Electric's EcoStruxure Power Monitoring Expert and Power Operations platforms (versions 2022-2024 R2) contain a privilege escalation vulnerability allowing locally authenticated users to execute arbitrary code with administrative access, fully compromising power management systems and operational data integrity. This directly threatens critical infrastructure availability and reliability. While no public exploit currently exists, the lack of available patches elevates the importance of immediate access controls and compensating measures.

Recommended Action

Within 24 hours, inventory all systems running EcoStruxure Power Monitoring Expert (2022-2024 R2) or EcoStruxure Power Operations (2022, 2024), document all local user accounts with access, and verify audit logging is enabled on affected systems. Within 7 days, restrict local administrative access to essential personnel only, revoke unnecessary privileges from local accounts, and implement network segmentation to isolate power management infrastructure from general corporate networks where operationally feasible. Within 30 days, monitor Schneider Electric security advisories and vendor channels for patch releases, and apply any available patches immediately; simultaneously engage vendor support to request interim hardening guidance or workarounds for production systems.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations: (1) enforce principle of least privilege by restricting local system access and administrative rights to essential operations personnel only; (2) enable comprehensive audit logging and real-time monitoring for suspicious process execution and privilege escalation attempts on all affected EcoStruxure systems; (3) implement network segmentation to isolate power management platforms from general corporate networks; (4) establish regular documented review of active local user accounts and maintain baseline of authorized access; (5) restrict physical and remote access to systems running affected versions; (6) monitor Schneider Electric security channels for patch availability or published mitigations.

Threat Intelligence Overview

EPSS Score
0.1%
Top 80% exploitable
Threat Intel
1
1 source
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.1%
Patch available No
Active threat Yes
Deciding rule
Active threat signals + CRITICAL/HIGH severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Small
Automatable· derived
No
Human Impact
High

Priority Score

52
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +42
PoC: 0
Weaponized: 0
Threat intel: +10
Gov advisory: 0

Attack Technique

Insecure deserialization occurs when an application converts serialized data (a stream of bytes representing an object's state) back into a living object without proper validation.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

Affected Products (CPE)CVE.org

cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2022:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2023:-:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2023:r2:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2024:-:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2024:r2:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_power_operation:2022:*:*:*:*:*:*:*
cpe:2.3:a:schneider-electric:ecostruxure_power_operation:2024:*:*:*:*:*:*:*

Threat IntelligenceMISP

CISA Advisories
Sources: CISA (public domain)

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy