Skip to main content

Schneider NetBotz CVE-2026-13337

| EUVDEUVD-2026-69134 MEDIUM
SQL Injection: Hibernate (CWE-564)
2026-09-01 schneider GHSA-hq47-cf6c-9h3p
5.1
CVSS 4.0 · Vendor: schneider
Share

Severity by source

Vendor (schneider) PRIMARY
5.1 MEDIUM
CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
4.6 MEDIUM

Adjacent-network access and a valid low-privilege account are both required; confidentiality and integrity impact are limited to the local database with no availability or scope-change effect.

3.1 AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
4.0 AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N

Primary rating from Vendor (schneider).

CVSS VectorVendor: schneider

Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

1
Analysis Generated
Sep 01, 2026 - 14:09 vuln.today

DescriptionCVE.org

CWE-564: SQL Injection: Hibernate vulnerability exists that could allow the injection of a malicious HQL query in the NetBotz database when a malicious user is logged into the NetBotz via the web-service interface or webui.

AnalysisAI

HQL injection in Schneider Electric NetBotz 5 models 750 and 755 allows an authenticated attacker on the same adjacent network segment to inject malicious Hibernate Query Language statements through the appliance's web service interface or web UI, gaining limited unauthorized read and write access to the NetBotz database. The CVSS 4.0 score of 5.1 reflects a constrained attack surface - both network adjacency and a valid low-privilege account are prerequisites. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Exploitation requires all three of the following: (1) the attacker holds a valid low-privilege account on the NetBotz 5 750/755 appliance (PR:L confirmed by CVSS); (2) the attacker is positioned on the same adjacent network segment as the appliance (AV:A - internet-based remote exploitation is structurally excluded); (3) the attack is delivered through the appliance's web service interface or web UI, both of which must be reachable from the attacker's position. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The vendor-supplied CVSS 4.0 vector AV:A/AC:L/AT:N/PR:L/UI:N with impacts VC:L/VI:L/VA:N yields a score of 5.1 (Medium), which accurately reflects the bounded threat. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation Consult Schneider Electric advisory SEVD-2026-223-02 at https://download.se.com/files?p_Doc_Ref=SEVD-2026-223-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-223-02.pdf for the authoritative patched firmware version - no specific fix version was included in the available intelligence data. … Detailed patch versions, workarounds, and compensating controls in full report.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

CVE-2026-13337 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy