Skip to main content

Schneider Electric SCADAPack CVE-2026-81861

| EUVDEUVD-2026-76131 MEDIUM
Insufficiently Protected Credentials (CWE-522)
2026-09-11 schneider GHSA-qf5h-x8xh-fc35
5.9
CVSS 4.0 · Vendor: schneider
Share

Severity by source

Vendor (schneider) PRIMARY
5.9 MEDIUM
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
5.3 MEDIUM

Network-interceptable credential exposure requiring specific attacker positioning (AC:H) and user authentication action (UI:R); confidentiality-only impact with no integrity or availability consequence.

3.1 AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N
4.0 AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

Primary rating from Vendor (schneider).

CVSS VectorVendor: schneider

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
A
Scope
X

Lifecycle Timeline

2
Metadata Corrected
Sep 11, 2026 - 16:40 vuln.today
tag: Authentication Bypass removed
Analysis Generated
Sep 11, 2026 - 15:51 vuln.today

DescriptionCVE.org

CWE-522: Insufficiently Protected Credentials vulnerability that could result in exposure of authentication information and unauthorized access to RTU functionality.

AnalysisAI

Credential interception vulnerability in Schneider Electric SCADAPack RTUs (Remote Terminal Units) exposes authentication information over the network, enabling unauthorized access to RTU functionality. Affected products span the SCADAPack 3xx, 32, 47x/470R, and 57x families - all version ranges per CPE wildcards - used extensively in critical infrastructure sectors such as oil and gas pipelines, water systems, and electrical utilities. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Exploitation requires the attacker to achieve a network-level interception position between the client (engineering workstation or SCADA host) and the SCADAPack RTU - consistent with the CVSS 4.0 AT:P (Presence) attack requirement. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The published CVSS 4.0 score of 5.9 reflects meaningful real-world friction: AT:P (specific attack requirement, such as network interception capability) and UI:A (active user interaction required) significantly constrain opportunistic exploitation. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation Consult Schneider Electric Security Notice SEVD-2026-251-03 (https://download.se.com/files?p_Doc_Ref=SEVD-2026-251-03) for vendor-issued patches or firmware updates; no specific fixed version is independently confirmed from available CPE data, so the advisory is the definitive source. … Detailed patch versions, workarounds, and compensating controls in full report.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

CVE-2026-81861 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy