Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Network-reachable endpoint with no complexity beyond privileged credentials; no scope change as internal pivoting stays within the vulnerable system boundary.
Primary rating from Vendor (schneider).
CVSS VectorVendor: schneider
Lifecycle Timeline
2DescriptionCVE.org
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized command execution and disclosure of server data when an attacker with a privileged account sends crafted, unvalidated parameters to a server endpoint.
AnalysisAI
Server-Side Request Forgery in Schneider Electric EcoStruxure IT Data Center Expert (formerly StruxureWare Data Center Expert) versions 9.1.2 and prior enables a privileged authenticated attacker to send crafted, unvalidated parameters to a server endpoint, causing the platform to make unauthorized outbound or internal requests. The resulting impact spans unauthorized command execution and disclosure of server-side data - a unusually severe outcome for SSRF, likely achieved by pivoting through the SSRF to reach privileged internal services. …
Unlock full vulnerability intelligence
- Risk assessment & exploitation conditions
- Attack chain visualization
- Remediation with exact patch versions
- Threat intelligence from 22 sources
- Personal watchlist & email alerts
Free forever · No credit card required
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata
Vulnerability AssessmentAI
| Exploitation | Exploitation requires an active privileged account on the EcoStruxure IT Data Center Expert platform (PR:H per the CVSS 4.0 vector); unauthenticated or low-privilege users cannot trigger this vulnerability. … Additional conditions and limiting factors are described in the full assessment. |
| Risk Assessment | The CVSS 4.0 vector AV:N/AC:L/AT:N/PR:H/UI:N with VC:H/VI:H/VA:H yields a score of 8.6, which accurately reflects the high confidentiality, integrity, and availability impact while acknowledging the significant mitigating factor: PR:H requires the attacker to already hold a privileged account on the platform. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in. |
| Exploit Scenario | Full exploit scenario with step-by-step reproduction available after sign-in. |
| Remediation | Upgrade EcoStruxure IT Data Center Expert to a version beyond 9.1.2, per Schneider Electric advisory SEVD-2026-251-01 available at https://download.se.com/files?p_Doc_Ref=SEVD-2026-251-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-251-01.pdf. … Detailed patch versions, workarounds, and compensating controls in full report. |
Recommended ActionAI
Within 24 hours, audit all administrative account access logs for EcoStruxure IT Data Center Expert 9.1.2 and earlier, and inventory all systems running this version. …
Sign in for detailed remediation steps and compensating controls.