Ecostruxure It Data Center Expert Formerly Known As Struxureware Data Center Expert
Monthly
Server-Side Request Forgery in Schneider Electric EcoStruxure IT Data Center Expert (formerly StruxureWare Data Center Expert) versions 9.1.2 and prior enables a privileged authenticated attacker to send crafted, unvalidated parameters to a server endpoint, causing the platform to make unauthorized outbound or internal requests. The resulting impact spans unauthorized command execution and disclosure of server-side data - a unusually severe outcome for SSRF, likely achieved by pivoting through the SSRF to reach privileged internal services. No public exploit has been identified at time of analysis, and the vulnerability is not listed in CISA KEV.
Remote code execution is possible in Schneider Electric EcoStruxure IT Data Center Expert (formerly StruxureWare Data Center Expert) versions 9.1.2 and prior via an argument injection flaw (CWE-88) in backup configuration parameter handling. An attacker holding a privileged account can supply crafted arguments that are passed unsanitized to an underlying backup command, resulting in arbitrary OS-level code execution on the server. No public exploit code or active exploitation has been identified at time of analysis, but the network-reachable attack vector and full CIA impact make this a meaningful risk for any organization operating this data center infrastructure management platform.
Server-Side Request Forgery in Schneider Electric EcoStruxure IT Data Center Expert (formerly StruxureWare Data Center Expert) versions 9.1.2 and prior enables a privileged authenticated attacker to send crafted, unvalidated parameters to a server endpoint, causing the platform to make unauthorized outbound or internal requests. The resulting impact spans unauthorized command execution and disclosure of server-side data - a unusually severe outcome for SSRF, likely achieved by pivoting through the SSRF to reach privileged internal services. No public exploit has been identified at time of analysis, and the vulnerability is not listed in CISA KEV.
Remote code execution is possible in Schneider Electric EcoStruxure IT Data Center Expert (formerly StruxureWare Data Center Expert) versions 9.1.2 and prior via an argument injection flaw (CWE-88) in backup configuration parameter handling. An attacker holding a privileged account can supply crafted arguments that are passed unsanitized to an underlying backup command, resulting in arbitrary OS-level code execution on the server. No public exploit code or active exploitation has been identified at time of analysis, but the network-reachable attack vector and full CIA impact make this a meaningful risk for any organization operating this data center infrastructure management platform.