Lifecycle Timeline
1DescriptionNVD
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application.
AnalysisAI
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Deserialization of Untrusted Data (CWE-502), which allows attackers to execute arbitrary code through malicious serialized objects. A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application. Affected products include: Schneider-Electric Ecostruxure Power Monitoring Expert, Schneider-Electric Ecostruxure Power Operation With Advanced Reports, Schneider-Electric Ecostruxure Power Scada Operation With Advanced Reports.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid deserializing untrusted data. Use safe serialization formats (JSON). Implement integrity checks and type allowlists.
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administr
A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain unauthorized ac
A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA So
A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Sof
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cau
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading
A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure
A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStru
Same weakness CWE-502 – Deserialization of Untrusted Data
View allShare