Skip to main content

Honeywell EUVDEUVD-2025-21067

| CVE-2025-2521 HIGH
Buffer Overflow (CWE-119)
2025-07-10 psirt@honeywell.com
8.6
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.6 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
Low
Availability
High

Lifecycle Timeline

3
EUVD ID Assigned
Mar 16, 2026 - 06:52 euvd
EUVD-2025-21067
Analysis Generated
Mar 16, 2026 - 06:52 vuln.today
CVE Published
Jul 10, 2025 - 21:15 nvd
HIGH 8.6

DescriptionCVE.org

The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution.

Honeywell recommends updating to the most recent version of Honeywell Experion PKS:

520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.

The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.

AnalysisAI

A remote code execution vulnerability in Honeywell Experion PKS and OneWireless WDM (CVSS 8.6). High severity vulnerability requiring prompt remediation.

Technical ContextAI

CWE-119 (Buffer Overflow). CVSS 8.6 indicates high severity. Affects Honeywell Experion PKS and OneWireless WDM.

RemediationAI

Monitor vendor channels for patch availability. Consider network segmentation to limit exposure if patching is delayed.

CVE-2013-0108 MEDIUM POC
6.8 Feb 24

An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R

CVE-2015-0984 CRITICAL POC
10.0 Mar 31

Directory traversal vulnerability in the FTP server on Honeywell Excel Web XL1000C50 52 I/O, XL1000C100 104 I/O, XL1000C

CVE-2023-3710 CRITICAL POC
9.8 Sep 12

Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injec

CVE-2017-14263 HIGH
8.1 Sep 11

Honeywell NVR devices allow remote attackers to create a user account in the admin group by leveraging access to a guest

CVE-2017-5671 HIGH POC
8.8 Mar 29

Honeywell Intermec PM23, PM42, PM43, PC23, PC43, PD43, and PC42 industrial printers before 10.11.013310 and 10.12.x befo

CVE-2014-8269 HIGH
7.5 Dec 13

Multiple stack-based buffer overflows in (1) HWOPOSScale.ocx and (2) HWOPOSSCANNER.ocx in Honeywell OPOS Suite before 1.

CVE-2025-2605 CRITICAL
9.9 May 02

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB

CVE-2026-3611 CRITICAL
10.0 Mar 12

Unauthenticated access to Honeywell IQ4x building controller HMI. CVSS 10.0.

CVE-2017-5140 CRITICAL
9.8 Feb 13

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-

CVE-2017-5139 CRITICAL
9.8 Feb 13

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-

CVE-2023-25178 CRITICAL
9.8 Jul 13

Controller may be loaded with malicious firmware which could enable remote code execution. Rated critical severity (CVSS

CVE-2022-30318 CRITICAL
9.8 Aug 31

Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. Rated critical severity (CVSS 9.8), this vulnerability

Share

EUVD-2025-21067 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy