2DescriptionCVE.org
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product.
AnalysisAI
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse.04 before V12.53 and MB-Secure PRO from V01.06. Rated critical severity (CVSS 9.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product. Affected products include: Honeywell Mb-Secure Firmware, Honeywell Mb-Secure Pro Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.
An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R
Directory traversal vulnerability in the FTP server on Honeywell Excel Web XL1000C50 52 I/O, XL1000C100 104 I/O, XL1000C
Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injec
Honeywell NVR devices allow remote attackers to create a user account in the admin group by leveraging access to a guest
Honeywell Intermec PM23, PM42, PM43, PC23, PC43, PD43, and PC42 industrial printers before 10.11.013310 and 10.12.x befo
Multiple stack-based buffer overflows in (1) HWOPOSScale.ocx and (2) HWOPOSSCANNER.ocx in Honeywell OPOS Suite before 1.
Unauthenticated access to Honeywell IQ4x building controller HMI. CVSS 10.0.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-
Controller may be loaded with malicious firmware which could enable remote code execution. Rated critical severity (CVSS
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. Rated critical severity (CVSS 9.8), this vulnerability
Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity
Same weakness CWE-78 – OS Command Injection
View allSame technique Command Injection