Skip to main content

Honeywell CVE-2026-3611

CRITICAL
Missing Authentication for Critical Function (CWE-306)
2026-03-12 ics-cert@hq.dhs.gov
10.0
CVSS 4.0 · NVD
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Connect to HTTP interface
  2. Delivery
    Access U.htm endpoint unauthenticated
  3. Exploit
    Create administrative account
  4. Execution
    Modify building management system settings
  5. Impact
    Disable safety controls or extract sensitive data

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Authentication required for critical functions
MITRE ATT&CK

1 technique across 1 tactic: Initial Access

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Honeywell IQ4x controller in factory-default configuration with no user module configured. System Guest (level 100) context active, granting unauthenticated read/write access to HTTP HMI interface and U.htm account creation function.

Impact

CVSS 10.0. Building automation controller with no authentication.

Exploit ScenarioDerived

Full unauthenticated access to building management.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 12, 2026

Unauthenticated access to Honeywell IQ4x building controller HMI. CVSS 10.0.

Earlier versions of this analysis (1)
v1 Mar 12, 2026 - 22:55 CVSS 10.0

No auth on Honeywell building controller.

RemediationAI

Configure authentication.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

CWE-306 in factory default config.

Know when Honeywell gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 10.0 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
High
Subsequent system: Integrity
High
Subsequent system: Availability
High

DescriptionCVE.org

The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration.

Executive ViewAI

Why It Matters

Honeywell IQ4x building management controllers in their default configuration expose critical infrastructure control interfaces without any authentication, allowing unauthorized remote access to HVAC, lighting, and physical security systems. Any organization operating these devices faces immediate risk of facility disruption, safety incidents, and potential data exfiltration affecting business continuity.

Business Impact: Severe
Compensating Controls

Immediate mitigations pending vendor patch: (1) Implement network segmentation—restrict IQ4x device access via firewall to authorized administrative networks only; (2) Deploy reverse proxy/WAF with authentication enforcement in front of the HMI interface; (3) Change all factory-default credentials immediately; (4) Disable web-based HMI access if not operationally required, use local console only; (5) Enable network-based intrusion detection/prevention on IQ4x traffic; (6) Implement VPN/jump-host requirement for any remote access to these devices; (7) Monitor for suspicious access patterns to IQ4x management interfaces.

Threat Intelligence Overview

EPSS Score
0.1%
Top 67% exploitable
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
Very High

Priority Score

50
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +50
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

Affected Products (CPE)CVE.org

cpe:2.3:o:honeywell:iq4e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:honeywell:iq412_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:honeywell:iq422_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:honeywell:iq4nc_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:honeywell:iq41x_firmware:*:*:*:*:*:*:*:*
CVE-2013-0108 MEDIUM POC
6.8 Feb 24

An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R

CVE-2015-0984 CRITICAL POC
10.0 Mar 31

Directory traversal vulnerability in the FTP server on Honeywell Excel Web XL1000C50 52 I/O, XL1000C100 104 I/O, XL1000C

CVE-2023-3710 CRITICAL POC
9.8 Sep 12

Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injec

CVE-2017-14263 HIGH
8.1 Sep 11

Honeywell NVR devices allow remote attackers to create a user account in the admin group by leveraging access to a guest

CVE-2017-5671 HIGH POC
8.8 Mar 29

Honeywell Intermec PM23, PM42, PM43, PC23, PC43, PD43, and PC42 industrial printers before 10.11.013310 and 10.12.x befo

CVE-2014-8269 HIGH
7.5 Dec 13

Multiple stack-based buffer overflows in (1) HWOPOSScale.ocx and (2) HWOPOSSCANNER.ocx in Honeywell OPOS Suite before 1.

CVE-2024-46453 MEDIUM POC
6.1 Sep 27

A cross-site scripting (XSS) vulnerability in the component /test/ of iq3xcite v2.31 to v3.05 allows attackers to execut

CVE-2025-2605 CRITICAL
9.9 May 02

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB

CVE-2017-5140 CRITICAL
9.8 Feb 13

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-

CVE-2017-5139 CRITICAL
9.8 Feb 13

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-

CVE-2026-13249 CRITICAL
9.8 Sep 24

Unauthenticated remote code execution in Honeywell PD45 Industrial Printer firmware F10.19.010040 lets any network-reach

CVE-2023-25178 CRITICAL
9.8 Jul 13

Controller may be loaded with malicious firmware which could enable remote code execution. Rated critical severity (CVSS

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy