Skip to main content

Circuit Design Suite CVE-2025-6033

HIGH
Out-of-bounds Write (CWE-787)
2025-09-30 security@ni.com
8.5
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
8.5 HIGH
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Local
Attack Complexity
Low
Privileges Required
None
User Interaction
P
Scope
X

Lifecycle Timeline

2
Analysis Generated
Mar 28, 2026 - 19:15 vuln.today
CVE Published
Sep 30, 2025 - 16:15 nvd
HIGH 8.5

DescriptionCVE.org

There is a memory corruption vulnerability due to an out of bounds write in XML_Serialize() when using SymbolEditor in NI Circuit Design Suite.  This vulnerability may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .sym file. This vulnerability affects NI Circuit Design Suite 14.3.1 and prior versions.

AnalysisAI

There is a memory corruption vulnerability due to an out of bounds write in XML_Serialize() when using SymbolEditor in NI Circuit Design Suite. Rated high severity (CVSS 8.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Out-of-bounds Write (CWE-787), which allows attackers to write data beyond allocated buffer boundaries leading to code execution or crashes. There is a memory corruption vulnerability due to an out of bounds write in XML_Serialize() when using SymbolEditor in NI Circuit Design Suite. This vulnerability may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .sym file. This vulnerability affects NI Circuit Design Suite 14.3.1 and prior versions. Affected products include: Ni Circuit Design Suite.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate write boundaries, use memory-safe languages, enable compiler protections (ASLR, stack canaries).

Share

CVE-2025-6033 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy