Ac7 Firmware
CVE-2018-14492
HIGH
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Lifecycle Timeline
1DescriptionNVD
Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI.
AnalysisAI
Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified as Out-of-bounds Write (CWE-787), which allows attackers to write data beyond allocated buffer boundaries leading to code execution or crashes. Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI. Affected products include: Tendacn Ac7 Firmware, Tendacn Ac9 Firmware, Tendacn Ac10 Firmware, Tendacn Ac15 Firmware, Tendacn Ac18 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate write boundaries, use memory-safe languages, enable compiler protections (ASLR, stack canaries).
More in Ac7 Firmware
View allTenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set f
Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle fun
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to co
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeC
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to co
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasi
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parame
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0
Same weakness CWE-787 – Out-of-bounds Write
View allSame technique Memory Corruption
View allShare
External POC / Exploit Code
Leaving vuln.today