Skip to main content

Tendacn

117 CVEs vendor

Monthly

CVE-2025-29032 Mar 14, 14:15 MEDIUM POC This Month

Tenda AC9 v15.03.05.19(6318) was discovered to contain a buffer overflow via the formWifiWpsOOB function. Rated medium severity (CVSS 5.9), this vulnerability is remotely exploitable. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac9 Firmware Tendacn
NVD GitHub
CVSS 3.1
5.9
EPSS
0.1%
CVE-2024-50854 Nov 13, 15:15 HIGH POC This Week

Tenda G3 v3.0 v15.11.0.20 was discovered to contain a stack overflow via the formSetPortMapping function. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda G3 Firmware Tendacn
NVD GitHub
CVSS 3.1
8.8
EPSS
0.5%
CVE-2024-50853 Nov 13, 15:15 HIGH POC This Week

Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetDebugCfg function. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Command Injection Tenda G3 Firmware Tendacn
NVD GitHub
CVSS 3.1
8.8
EPSS
1.6%
CVE-2024-50852 Nov 13, 15:15 HIGH POC This Week

Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetUSBPartitionUmount function. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Command Injection Tenda G3 Firmware Tendacn
NVD GitHub
CVSS 3.1
8.8
EPSS
1.6%
CVE-2024-46628 Sep 26, 20:15 CRITICAL POC THREAT Act Now

Tenda G3 Router firmware v15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the usbPartitionName parameter in the formSetUSBPartitionUmount function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RCE Command Injection Tenda G3 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
11.3%
CVE-2024-8224 Aug 27, 23:15 HIGH POC This Week

A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda G3 Firmware Tendacn
NVD GitHub VulDB
CVSS 4.0
8.7
EPSS
1.2%
CVE-2024-42954 Aug 15, 17:15 HIGH POC This Week

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromwebExcptypemanFilter function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Denial Of Service Memory Corruption Tenda Fh1201 Firmware +1
NVD GitHub
CVSS 3.1
7.5
EPSS
0.6%
CVE-2024-42953 Aug 15, 17:15 HIGH POC This Week

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the PPW parameter in the fromWizardHandle function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Denial Of Service Memory Corruption Tenda Fh1201 Firmware +1
NVD GitHub
CVSS 3.1
7.5
EPSS
0.6%
CVE-2024-42949 Aug 15, 17:15 HIGH POC This Week

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Denial Of Service Memory Corruption Tenda Fh1201 Firmware +1
NVD GitHub
CVSS 3.1
7.5
EPSS
0.6%
CVE-2024-42945 Aug 15, 17:15 HIGH POC This Week

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromAddressNat function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Denial Of Service Memory Corruption Tenda Fh1201 Firmware +1
NVD GitHub
CVSS 3.1
7.5
EPSS
0.7%
CVE-2024-42942 Aug 15, 17:15 HIGH POC This Week

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the frmL7ImForm function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Denial Of Service Memory Corruption Tenda Fh1201 Firmware +1
NVD GitHub
CVSS 3.1
7.5
EPSS
0.7%
CVE-2024-7581 Aug 07, 15:15 HIGH POC This Week

A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda A301 Firmware Tendacn
NVD GitHub VulDB
CVSS 4.0
8.7
EPSS
1.4%
CVE-2024-41473 Jul 25, 22:15 CRITICAL POC Act Now

Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the mac parameter at ip/goform/WriteFacMac. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Command Injection Tenda Fh1201 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
6.7%
CVE-2024-41468 Jul 25, 22:15 CRITICAL Act Now

Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the cmdinput parameter at /goform/exeCommand. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Command Injection Tenda Fh1201 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
4.6%
CVE-2024-41466 Jul 24, 21:15 HIGH POC This Week

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/NatStaticSetting. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Fh1201 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.6%
CVE-2024-41465 Jul 24, 21:15 HIGH POC This Week

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/setcfm. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Fh1201 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.6%
CVE-2024-41464 Jul 24, 21:15 HIGH POC This Week

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/RouteStatic. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Fh1201 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.6%
CVE-2024-41463 Jul 24, 21:15 HIGH POC This Week

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/addressNat. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Fh1201 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.5%
CVE-2024-41462 Jul 24, 21:15 HIGH POC This Week

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/DhcpListClient. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Fh1201 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.6%
CVE-2024-41461 Jul 24, 21:15 CRITICAL POC Act Now

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the list1 parameter at ip/goform/DhcpListClient. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Fh1201 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.6%
CVE-2024-41460 Jul 24, 21:15 CRITICAL POC Act Now

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/RouteStatic. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Fh1201 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.6%
CVE-2024-41459 Jul 24, 21:15 CRITICAL POC Act Now

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter at ip/goform/QuickIndex. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Fh1201 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.6%
CVE-2024-35338 Jul 16, 16:15 CRITICAL POC Act Now

Tenda i29V1.0 V1.0.0.5 was discovered to contain a hardcoded password for root. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Authentication Bypass Tenda I29 Firmware Tendacn
NVD
CVSS 3.1
9.8
EPSS
0.5%
CVE-2024-33182 Jul 16, 16:15 CRITICAL POC Act Now

Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/addWifiMacFilter. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac18 Firmware Tendacn
NVD
CVSS 3.1
9.8
EPSS
0.6%
CVE-2024-33180 Jul 16, 16:15 CRITICAL POC Act Now

Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac18 Firmware Tendacn
NVD
CVSS 3.1
9.8
EPSS
0.6%
CVE-2024-6403 Jun 28, 17:15 HIGH POC This Week

A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Rated high severity (CVSS 7.1), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda A301 Firmware Tendacn
NVD GitHub VulDB
CVSS 4.0
7.1
EPSS
1.0%
CVE-2024-6402 Jun 28, 17:15 HIGH POC This Week

A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Rated high severity (CVSS 7.1), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda A301 Firmware Tendacn
NVD VulDB GitHub
CVSS 4.0
7.1
EPSS
1.0%
CVE-2024-6189 Jun 20, 14:15 HIGH POC This Week

A vulnerability was found in Tenda A301 15.13.08.12. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda A301 Firmware Tendacn
NVD VulDB
CVSS 4.0
8.7
EPSS
1.4%
CVE-2024-24488 Feb 07, 20:15 MEDIUM This Month

An issue in Shenzen Tenda Technology CP3V2.0 V11.10.00.2311090948 allows a local attacker to obtain sensitive information via the password component. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. No vendor patch available.

Information Disclosure Tenda Cp3 Firmware Tendacn
NVD GitHub
CVSS 3.1
5.5
EPSS
0.2%
CVE-2024-0932 Jan 26, 17:15 CRITICAL POC Act Now

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
0.9%
CVE-2024-0931 Jan 26, 17:15 CRITICAL POC Act Now

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
0.9%
CVE-2024-0930 Jan 26, 16:15 CRITICAL POC THREAT Act Now

A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
15.2%
CVE-2024-0929 Jan 26, 16:15 CRITICAL POC Act Now

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
1.1%
CVE-2024-0928 Jan 26, 16:15 CRITICAL POC Act Now

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
1.1%
CVE-2024-0927 Jan 26, 15:15 CRITICAL POC Act Now

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
0.8%
CVE-2024-0926 Jan 26, 15:15 CRITICAL POC Act Now

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
0.9%
CVE-2024-0925 Jan 26, 15:15 CRITICAL POC Act Now

A vulnerability has been found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
0.9%
CVE-2024-0923 Jan 26, 14:15 CRITICAL POC Act Now

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
0.9%
CVE-2024-0922 Jan 26, 14:15 CRITICAL POC Act Now

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
0.9%
CVE-2024-0535 Jan 15, 03:15 CRITICAL Act Now

A vulnerability classified as critical was found in Tenda PA6 1.0.1.21. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Stack Overflow Tenda Pa6 Firmware Tendacn
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
1.0%
CVE-2023-44023 Sep 27, 15:19 CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2023-44022 Sep 27, 15:19 CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2023-44021 Sep 27, 15:19 CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the formSetClientState function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2023-44020 Sep 27, 15:19 CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2023-44019 Sep 27, 15:19 CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the mac parameter in the GetParentControlInfo function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2023-44018 Sep 27, 15:19 CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the domain parameter in the add_white_node function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
15.4%
CVE-2023-44017 Sep 27, 15:19 CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2023-44016 Sep 27, 15:19 CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2023-44015 Sep 27, 15:19 CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the schedEndTime parameter in the setSchedWifi function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.6%
CVE-2023-44014 Sep 27, 15:19 CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain multiple stack overflows in the formSetMacFilterCfg function via the macFilterType and deviceList parameters. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2023-44013 Sep 27, 15:19 CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the list parameter in the fromSetIpMacBind function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2023-40942 Sep 07, 15:15 CRITICAL POC Act Now

Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/SetFirewallCfg. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac9 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-37144 Jul 07, 14:15 CRITICAL POC Act Now

Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Command Injection Tenda Ac10 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
2.4%
CVE-2022-45661 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the setSmartPowerManagement function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45660 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the schedStartTime parameter in the setSchedWifi function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45659 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45658 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the schedEndTime parameter in the setSchedWifi function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45657 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the list parameter in the fromSetIpMacBind function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45656 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the fromSetSysTime function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45655 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the timeZone parameter in the form_fast_setting_wifi_set function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45654 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the ssid parameter in the form_fast_setting_wifi_set function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45653 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the page parameter in the fromNatStaticSetting function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45652 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the startIp parameter in the formSetPPTPServer function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45651 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the list parameter in the formSetVirtualSer function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45650 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the firewallEn parameter in the formSetFirewallCfg function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45649 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the endIp parameter in the formSetPPTPServer function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45648 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the devName parameter in the formSetDeviceName function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45647 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the limitSpeed parameter in the formSetClientState function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45646 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the limitSpeedUp parameter in the formSetClientState function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45645 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceMac parameter in the addWifiMacFilter function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45644 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the formSetClientState function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-45643 Dec 02, 18:15 HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the addWifiMacFilter function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware Tendacn
NVD GitHub
CVSS 3.1
7.5
EPSS
0.8%
CVE-2022-40869 Sep 23, 14:15 CRITICAL POC Act Now

Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function fromDhcpListClient with a combined parameter "list*" ("%s%d","list"). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac15 Firmware Ac18 Firmware +1
NVD GitHub
CVSS 3.1
9.8
EPSS
1.2%
CVE-2022-40865 Sep 23, 14:15 CRITICAL POC Act Now

Tenda AC15 and AC18 routers V15.03.05.19 contain heap overflow vulnerabilities in the function setSchedWifi with the request /goform/openSchedWifi/. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac15 Firmware Ac18 Firmware +1
NVD GitHub
CVSS 3.1
9.8
EPSS
1.2%
CVE-2022-40864 Sep 23, 14:15 CRITICAL POC Act Now

Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function setSmartPowerManagement with the request /goform/PowerSaveSet. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac15 Firmware Ac18 Firmware +1
NVD GitHub
CVSS 3.1
9.8
EPSS
1.2%
CVE-2022-40862 Sep 23, 14:15 CRITICAL POC Act Now

Tenda AC15 and AC18 router V15.03.05.19 contains stack overflow vulnerability in the function fromNatStaticSetting with the request /goform/NatStaticSetting. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac15 Firmware Ac18 Firmware +1
NVD GitHub
CVSS 3.1
9.8
EPSS
1.2%
CVE-2022-40860 Sep 23, 14:15 CRITICAL POC Act Now

Tenda AC15 router V15.03.05.19 contains a stack overflow vulnerability in the function formSetQosBand->FUN_0007dd20 with request /goform/SetNetControlList. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac15 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
1.0%
CVE-2022-40853 Sep 23, 14:15 CRITICAL POC Act Now

Tenda AC15 router V15.03.05.19 contains a stack overflow via the list parameter at /goform/fast_setting_wifi_set. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac15 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
1.0%
CVE-2022-38326 Sep 15, 20:15 CRITICAL POC Act Now

Tenda AC15 WiFi Router V15.03.05.19_multi and AC18 WiFi Router V15.03.05.19_multi were discovered to contain a buffer overflow via the page parameter at /goform/NatStaticSetting. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac15 Firmware Ac18 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2022-38325 Sep 15, 20:15 CRITICAL POC Act Now

Tenda AC15 WiFi Router V15.03.05.19_multi and AC18 WiFi Router V15.03.05.19_multi were discovered to contain a buffer overflow via the filePath parameter at /goform/expandDlnaFile. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac15 Firmware Ac18 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2022-37176 Aug 30, 16:15 CRITICAL Act Now

Tenda AC6(AC1200) v5.0 Firmware v02.03.01.114 and below contains a vulnerability which allows attackers to remove the Wi-Fi password and force the device into open security mode via a crafted packet. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Tenda Ac6 Firmware Tendacn
NVD VulDB
CVSS 3.1
9.8
EPSS
1.0%
CVE-2022-36552 Aug 30, 16:15 HIGH This Week

Tenda AC6(AC1200) v5.0 Firmware v02.03.01.114 and below contains an issue in the component /cgi-bin/DownloadFlash which allows attackers to steal all data such as source code and system files via a. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Path Traversal Tenda Ac6 Firmware Tendacn
NVD VulDB
CVSS 3.1
7.5
EPSS
0.7%
CVE-2022-36233 Aug 19, 22:15 MEDIUM POC This Month

Tenda AC9 V15.03.2.13 is vulnerable to Buffer Overflow via httpd, form_fast_setting_wifi_set. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac9 Firmware Tendacn
NVD VulDB
CVSS 3.1
5.5
EPSS
0.3%
CVE-2022-32386 Jul 06, 12:15 CRITICAL POC THREAT Emergency

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 11.2%.

Buffer Overflow Memory Corruption Tenda Ac23 Ac2100 Firmware Tendacn
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
11.2%
CVE-2022-32385 Jul 06, 12:15 CRITICAL POC Act Now

Tenda AC23 v16.03.07.44 is vulnerable to Stack Overflow that will allow for the execution of arbitrary code (remote). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RCE Buffer Overflow Memory Corruption Tenda Ac23 Ac2100 Firmware +1
NVD GitHub VulDB
CVSS 3.1
9.8
EPSS
2.4%
CVE-2022-32383 Jul 06, 12:15 CRITICAL POC Act Now

Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the AdvSetMacMtuWan function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac23 Ac2100 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
1.4%
CVE-2022-32384 Jul 01, 21:15 HIGH POC This Week

Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the security_5g parameter in the function formWifiBasicSet. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac23 Ac2100 Firmware Tendacn
NVD VulDB
CVSS 3.1
8.8
EPSS
0.8%
CVE-2022-31446 Jun 14, 03:15 CRITICAL POC THREAT Act Now

Tenda AC18 router V15.03.05.19 and V15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RCE Command Injection Tenda Ac18 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
32.8%
CVE-2022-26243 Mar 23, 19:15 HIGH POC This Week

Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow in the setSmartPowerManagement function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac10 Firmware Tendacn
NVD
CVSS 3.1
7.5
EPSS
1.2%
CVE-2021-44352 Dec 03, 19:15 CRITICAL POC THREAT Act Now

A Stack-based Buffer Overflow vulnerability exists in the Tenda AC15 V15.03.05.18_multi device via the list parameter in a post request in goform/SetIpMacBind. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda Ac15 Firmware Tendacn
NVD GitHub
CVSS 3.1
9.8
EPSS
13.4%
EPSS 0% CVSS 5.9
MEDIUM POC This Month

Tenda AC9 v15.03.05.19(6318) was discovered to contain a buffer overflow via the formWifiWpsOOB function. Rated medium severity (CVSS 5.9), this vulnerability is remotely exploitable. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac9 Firmware +1
NVD GitHub
EPSS 1% CVSS 8.8
HIGH POC This Week

Tenda G3 v3.0 v15.11.0.20 was discovered to contain a stack overflow via the formSetPortMapping function. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 2% CVSS 8.8
HIGH POC This Week

Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetDebugCfg function. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Command Injection Tenda G3 Firmware +1
NVD GitHub
EPSS 2% CVSS 8.8
HIGH POC This Week

Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetUSBPartitionUmount function. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Command Injection Tenda G3 Firmware +1
NVD GitHub
EPSS 11% CVSS 9.8
CRITICAL POC THREAT Act Now

Tenda G3 Router firmware v15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the usbPartitionName parameter in the formSetUSBPartitionUmount function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RCE Command Injection Tenda +2
NVD GitHub
EPSS 1% CVSS 8.7
HIGH POC This Week

A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromwebExcptypemanFilter function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Denial Of Service Memory Corruption +3
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the PPW parameter in the fromWizardHandle function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Denial Of Service Memory Corruption +3
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Denial Of Service Memory Corruption +3
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromAddressNat function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Denial Of Service Memory Corruption +3
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the frmL7ImForm function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Denial Of Service Memory Corruption +3
NVD GitHub
EPSS 1% CVSS 8.7
HIGH POC This Week

A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 7% CVSS 9.8
CRITICAL POC Act Now

Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the mac parameter at ip/goform/WriteFacMac. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Command Injection Tenda Fh1201 Firmware +1
NVD GitHub
EPSS 5% CVSS 9.8
CRITICAL Act Now

Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the cmdinput parameter at /goform/exeCommand. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Command Injection Tenda Fh1201 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/NatStaticSetting. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/setcfm. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/RouteStatic. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/addressNat. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/DhcpListClient. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the list1 parameter at ip/goform/DhcpListClient. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/RouteStatic. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter at ip/goform/QuickIndex. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda i29V1.0 V1.0.0.5 was discovered to contain a hardcoded password for root. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Authentication Bypass Tenda I29 Firmware +1
NVD
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/addWifiMacFilter. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD
EPSS 1% CVSS 7.1
HIGH POC This Week

A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Rated high severity (CVSS 7.1), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 1% CVSS 7.1
HIGH POC This Week

A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Rated high severity (CVSS 7.1), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD VulDB GitHub
EPSS 1% CVSS 8.7
HIGH POC This Week

A vulnerability was found in Tenda A301 15.13.08.12. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD VulDB
EPSS 0% CVSS 5.5
MEDIUM This Month

An issue in Shenzen Tenda Technology CP3V2.0 V11.10.00.2311090948 allows a local attacker to obtain sensitive information via the password component. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. No vendor patch available.

Information Disclosure Tenda Cp3 Firmware +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 15% CVSS 9.8
CRITICAL POC THREAT Act Now

A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

A vulnerability has been found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL Act Now

A vulnerability classified as critical was found in Tenda PA6 1.0.1.21. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Stack Overflow Tenda +2
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the formSetClientState function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the mac parameter in the GetParentControlInfo function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware +1
NVD GitHub
EPSS 15% CVSS 9.8
CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the domain parameter in the add_white_node function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the schedEndTime parameter in the setSchedWifi function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain multiple stack overflows in the formSetMacFilterCfg function via the macFilterType and deviceList parameters. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL Act Now

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the list parameter in the fromSetIpMacBind function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10U Firmware +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/SetFirewallCfg. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Command Injection Tenda Ac10 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the setSmartPowerManagement function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the schedStartTime parameter in the setSchedWifi function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the schedEndTime parameter in the setSchedWifi function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the list parameter in the fromSetIpMacBind function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the fromSetSysTime function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the timeZone parameter in the form_fast_setting_wifi_set function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the ssid parameter in the form_fast_setting_wifi_set function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the page parameter in the fromNatStaticSetting function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the startIp parameter in the formSetPPTPServer function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the list parameter in the formSetVirtualSer function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the firewallEn parameter in the formSetFirewallCfg function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the endIp parameter in the formSetPPTPServer function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the devName parameter in the formSetDeviceName function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the limitSpeed parameter in the formSetClientState function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the limitSpeedUp parameter in the formSetClientState function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceMac parameter in the addWifiMacFilter function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the formSetClientState function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the addWifiMacFilter function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac6 Firmware +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function fromDhcpListClient with a combined parameter "list*" ("%s%d","list"). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +3
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC15 and AC18 routers V15.03.05.19 contain heap overflow vulnerabilities in the function setSchedWifi with the request /goform/openSchedWifi/. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +3
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function setSmartPowerManagement with the request /goform/PowerSaveSet. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +3
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC15 and AC18 router V15.03.05.19 contains stack overflow vulnerability in the function fromNatStaticSetting with the request /goform/NatStaticSetting. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +3
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC15 router V15.03.05.19 contains a stack overflow vulnerability in the function formSetQosBand->FUN_0007dd20 with request /goform/SetNetControlList. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC15 router V15.03.05.19 contains a stack overflow via the list parameter at /goform/fast_setting_wifi_set. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC15 WiFi Router V15.03.05.19_multi and AC18 WiFi Router V15.03.05.19_multi were discovered to contain a buffer overflow via the page parameter at /goform/NatStaticSetting. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac15 Firmware +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC15 WiFi Router V15.03.05.19_multi and AC18 WiFi Router V15.03.05.19_multi were discovered to contain a buffer overflow via the filePath parameter at /goform/expandDlnaFile. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac15 Firmware +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL Act Now

Tenda AC6(AC1200) v5.0 Firmware v02.03.01.114 and below contains a vulnerability which allows attackers to remove the Wi-Fi password and force the device into open security mode via a crafted packet. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Tenda Ac6 Firmware +1
NVD VulDB
EPSS 1% CVSS 7.5
HIGH This Week

Tenda AC6(AC1200) v5.0 Firmware v02.03.01.114 and below contains an issue in the component /cgi-bin/DownloadFlash which allows attackers to steal all data such as source code and system files via a. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Path Traversal Tenda +2
NVD VulDB
EPSS 0% CVSS 5.5
MEDIUM POC This Month

Tenda AC9 V15.03.2.13 is vulnerable to Buffer Overflow via httpd, form_fast_setting_wifi_set. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD VulDB
EPSS 11% CVSS 9.8
CRITICAL POC THREAT Emergency

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 11.2%.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub VulDB
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC23 v16.03.07.44 is vulnerable to Stack Overflow that will allow for the execution of arbitrary code (remote). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RCE Buffer Overflow Memory Corruption +3
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the AdvSetMacMtuWan function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
EPSS 1% CVSS 8.8
HIGH POC This Week

Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the security_5g parameter in the function formWifiBasicSet. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD VulDB
EPSS 33% CVSS 9.8
CRITICAL POC THREAT Act Now

Tenda AC18 router V15.03.05.19 and V15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RCE Command Injection Tenda +2
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow in the setSmartPowerManagement function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac10 Firmware +1
NVD
EPSS 13% CVSS 9.8
CRITICAL POC THREAT Act Now

A Stack-based Buffer Overflow vulnerability exists in the Tenda AC15 V15.03.05.18_multi device via the list parameter in a post request in goform/SetIpMacBind. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption Tenda +2
NVD GitHub
Page 1 of 2 Next

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy