CVE-2026-24441 MEDIUM This Month

Tenda AC7 firmware V03.03.03.01_cn and earlier transmits account credentials in cleartext over HTTP, enabling network-positioned attackers to intercept and obtain authentication material without user interaction. This cleartext credential exposure in HTTP responses creates a high confidentiality risk for affected device users. No patch is currently available for this vulnerability.

Information Disclosure Ac7 Firmware
NVD
CVSS 3.1
5.9
EPSS
0.0%
CVE-2026-24434 MEDIUM This Month

Tenda AC7 firmware through V03.03.03.01_cn lacks CSRF protections on administrative web functions, enabling attackers to trick authenticated administrators into executing unauthorized configuration changes. An unauthenticated attacker can craft malicious requests that, when visited by an admin, modify router settings without their knowledge or consent. No patch is currently available.

CSRF Ac7 Firmware
NVD
CVSS 3.1
6.5
EPSS
0.0%
CVE-2026-24427 MEDIUM This Month

Tenda AC7 firmware v03.03.03.01_cn and earlier transmits administrative credentials in plaintext within web management responses and fails to set proper Cache-Control headers, allowing credentials to be cached by browsers. A local attacker with access to a client system or browser profile can retrieve these cached credentials to gain unauthorized administrative access to affected routers. No patch is currently available for this vulnerability.

Information Disclosure Ac7 Firmware
NVD
CVSS 3.1
5.5
EPSS
0.0%
CVE-2026-24426 MEDIUM This Month

The Tenda AC7 firmware web management interface fails to properly sanitize user input, enabling reflected cross-site scripting (XSS) attacks that can inject malicious scripts into a victim's browser. An unauthenticated attacker can exploit this vulnerability to steal session cookies, perform unauthorized actions, or redirect users to malicious sites. No patch is currently available for affected firmware versions V03.03.03.01_cn and earlier.

XSS Ac7 Firmware
NVD
CVSS 3.1
6.1
EPSS
0.0%
CVE-2025-11523 LOW POC Monitor

Command injection in Tenda AC7 firmware 15.03.06.44 via the /goform/AdvSetLanip endpoint allows authenticated remote attackers to execute arbitrary commands with low impact on confidentiality, integrity, and availability. The vulnerability requires valid login credentials (PR:L) and affects the lanIp parameter. Publicly available exploit code exists, and EPSS scoring of 0.39% indicates low real-world exploitation probability despite public POC availability.

Command Injection Tenda Ac7 Firmware
NVD GitHub VulDB
CVSS 4.0
2.1
EPSS
0.4%
CVE-2025-9023 HIGH POC This Month

A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac18 Firmware Ac7 Firmware
NVD GitHub VulDB
CVSS 4.0
7.4
EPSS
0.4%
CVE-2025-5862 HIGH POC This Week

Critical remote buffer overflow vulnerability in Tenda AC7 wireless router firmware version 15.03.06.44, affecting the PPTP user list configuration function. An authenticated remote attacker can exploit this vulnerability to achieve arbitrary code execution with complete system compromise (confidentiality, integrity, and availability impact). Public exploit code has been disclosed and the vulnerability meets criteria for active exploitation risk.

Buffer Overflow Tenda Ac7 Firmware
NVD VulDB
CVSS 3.1
8.8
EPSS
0.3%
CVE-2025-5861 HIGH POC This Week

Critical remote buffer overflow vulnerability in Tenda AC7 router firmware version 15.03.06.44, affecting the LAN IP configuration function. An authenticated attacker can exploit improper input validation in the 'lanMask' parameter to achieve remote code execution with high confidentiality, integrity, and availability impact. Public exploit code is available and the vulnerability meets criteria for active exploitation.

Buffer Overflow Tenda Ac7 Firmware
NVD VulDB
CVSS 3.1
8.8
EPSS
0.4%
CVE-2025-4810 HIGH POC This Week

A vulnerability was found in Tenda AC7 15.03.06.44. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware
NVD VulDB
CVSS 4.0
8.7
EPSS
1.1%
CVE-2025-4809 HIGH POC This Week

A vulnerability was found in Tenda AC7 15.03.06.44. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware
NVD VulDB
CVSS 4.0
8.7
EPSS
1.1%
CVE-2025-3346 HIGH This Month

A vulnerability was found in Tenda AC7 15.03.06.44. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac7 Firmware
NVD GitHub VulDB
CVSS 4.0
8.7
EPSS
1.9%
CVE-2025-29135 CRITICAL POC Act Now

A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RCE Buffer Overflow Stack Overflow Tenda Ac7 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.2%
CVE-2025-29137 CRITICAL POC Act Now

Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set function, which can cause RCE. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
0.2%
CVE-2025-1851 HIGH This Week

A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac7 Firmware
NVD GitHub VulDB
CVSS 4.0
8.7
EPSS
0.8%
CVE-2025-1819 MEDIUM This Month

A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Command Injection Tenda Ac7 Firmware
NVD GitHub VulDB
CVSS 4.0
5.3
EPSS
1.7%
EPSS 0% CVSS 5.9
MEDIUM This Month

Tenda AC7 firmware V03.03.03.01_cn and earlier transmits account credentials in cleartext over HTTP, enabling network-positioned attackers to intercept and obtain authentication material without user interaction. This cleartext credential exposure in HTTP responses creates a high confidentiality risk for affected device users. No patch is currently available for this vulnerability.

Information Disclosure Ac7 Firmware
NVD
EPSS 0% CVSS 6.5
MEDIUM This Month

Tenda AC7 firmware through V03.03.03.01_cn lacks CSRF protections on administrative web functions, enabling attackers to trick authenticated administrators into executing unauthorized configuration changes. An unauthenticated attacker can craft malicious requests that, when visited by an admin, modify router settings without their knowledge or consent. No patch is currently available.

CSRF Ac7 Firmware
NVD
EPSS 0% CVSS 5.5
MEDIUM This Month

Tenda AC7 firmware v03.03.03.01_cn and earlier transmits administrative credentials in plaintext within web management responses and fails to set proper Cache-Control headers, allowing credentials to be cached by browsers. A local attacker with access to a client system or browser profile can retrieve these cached credentials to gain unauthorized administrative access to affected routers. No patch is currently available for this vulnerability.

Information Disclosure Ac7 Firmware
NVD
EPSS 0% CVSS 6.1
MEDIUM This Month

The Tenda AC7 firmware web management interface fails to properly sanitize user input, enabling reflected cross-site scripting (XSS) attacks that can inject malicious scripts into a victim's browser. An unauthenticated attacker can exploit this vulnerability to steal session cookies, perform unauthorized actions, or redirect users to malicious sites. No patch is currently available for affected firmware versions V03.03.03.01_cn and earlier.

XSS Ac7 Firmware
NVD
EPSS 0% CVSS 2.1
LOW POC Monitor

Command injection in Tenda AC7 firmware 15.03.06.44 via the /goform/AdvSetLanip endpoint allows authenticated remote attackers to execute arbitrary commands with low impact on confidentiality, integrity, and availability. The vulnerability requires valid login credentials (PR:L) and affects the lanIp parameter. Publicly available exploit code exists, and EPSS scoring of 0.39% indicates low real-world exploitation probability despite public POC availability.

Command Injection Tenda Ac7 Firmware
NVD GitHub VulDB
EPSS 0% CVSS 7.4
HIGH POC This Month

A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac18 Firmware +1
NVD GitHub VulDB
EPSS 0% CVSS 8.8
HIGH POC This Week

Critical remote buffer overflow vulnerability in Tenda AC7 wireless router firmware version 15.03.06.44, affecting the PPTP user list configuration function. An authenticated remote attacker can exploit this vulnerability to achieve arbitrary code execution with complete system compromise (confidentiality, integrity, and availability impact). Public exploit code has been disclosed and the vulnerability meets criteria for active exploitation risk.

Buffer Overflow Tenda Ac7 Firmware
NVD VulDB
EPSS 0% CVSS 8.8
HIGH POC This Week

Critical remote buffer overflow vulnerability in Tenda AC7 router firmware version 15.03.06.44, affecting the LAN IP configuration function. An authenticated attacker can exploit improper input validation in the 'lanMask' parameter to achieve remote code execution with high confidentiality, integrity, and availability impact. Public exploit code is available and the vulnerability meets criteria for active exploitation.

Buffer Overflow Tenda Ac7 Firmware
NVD VulDB
EPSS 1% CVSS 8.7
HIGH POC This Week

A vulnerability was found in Tenda AC7 15.03.06.44. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware
NVD VulDB
EPSS 1% CVSS 8.7
HIGH POC This Week

A vulnerability was found in Tenda AC7 15.03.06.44. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware
NVD VulDB
EPSS 2% CVSS 8.7
HIGH This Month

A vulnerability was found in Tenda AC7 15.03.06.44. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac7 Firmware
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RCE Buffer Overflow Stack Overflow +2
NVD GitHub
EPSS 0% CVSS 9.8
CRITICAL POC Act Now

Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set function, which can cause RCE. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware
NVD GitHub
EPSS 1% CVSS 8.7
HIGH This Week

A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac7 Firmware
NVD GitHub VulDB
EPSS 2% CVSS 5.3
MEDIUM This Month

A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Command Injection Tenda Ac7 Firmware
NVD GitHub VulDB

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy