Ac18 Firmware
CVE-2025-9023
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK
2 techniques across 2 tactics: Execution, Privilege Escalation The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 7.4 (HIGH). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. Public proof-of-concept exploit code is available. EPSS exploitation probability: 0.35%. |
| Exploit ScenarioDerived | A remote attacker could corrupt memory to execute arbitrary code or crash the application by sending crafted requests to the affected application. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Mar 28, 2026
A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use memory-safe languages or bounds-checking. Enable ASLR, DEP/NX, stack canaries. Use safe string functions.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Buffer Overflow (CWE-119), which allows attackers to corrupt memory to execute arbitrary code or crash the application. A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Affected products include: Tenda Ac7 Firmware, Tenda Ac18 Firmware.
Know when Ac18 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
2DescriptionCVE.org
A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Executive ViewAI
Organizations using A vulnerability face moderate risk from CVE-2025-9023, a buffer overflow vulnerability rated CVSS 7.4. Exploitation could allow attackers to corrupt memory, crash the application, or potentially execute arbitrary code. Proof-of-concept code is publicly available, increasing the risk of exploitation. Organizations should apply vendor updates when available and consider compensating controls in the interim.
Apply vendor patch. If immediate patching is not feasible: (1) Implement network-level access controls to limit exposure; (2) Enable enhanced monitoring and alerting; (3) Apply principle of least privilege.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
Affected Products (CPE)CVE.org
More in Ac18 Firmware
View allTenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId paramet
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId paramet
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function.
Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload func
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Rated critical severity (CVSS 9.8), thi
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function. Rated
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function. Rated critic
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function. Rat
Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName paramet
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet. Rated critical severity (CVSS 9.8
Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime fu
Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set. Rated critical severity (CV
GitHub PoC
Exploit-DB