Skip to main content

Ac10 Firmware

20 CVEs product

Monthly

CVE-2025-12622 HIGH This Month

A vulnerability was determined in Tenda AC10 16.03.10.13. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD VulDB
CVSS 4.0
7.4
EPSS
0.1%
CVE-2025-57220 MEDIUM This Month

An input validation flaw in the 'ate' service of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 to escalate privileges to root via a crafted UDP packet. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Privilege Escalation Tenda Ac10 Firmware
NVD
CVSS 3.1
5.3
EPSS
0.1%
CVE-2025-57219 MEDIUM This Month

Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Tenda Ac10 Firmware
NVD
CVSS 3.1
5.3
EPSS
0.1%
CVE-2025-57215 HIGH This Month

Tenda AC10 v4.0 firmware v16.03.10.20 was discovered to contain a stack overflow via the function get_parentControl_list_Info. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10 Firmware
NVD
CVSS 3.1
7.5
EPSS
0.1%
CVE-2025-57218 MEDIUM POC This Month

Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the security_5g parameter in the function sub_46284C. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10 Firmware
NVD
CVSS 3.1
5.3
EPSS
0.1%
CVE-2025-57217 MEDIUM This Month

Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the Password parameter in the function R7WebsSecurityHandler. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10 Firmware
NVD
CVSS 3.1
5.3
EPSS
0.1%
CVE-2025-5629 HIGH This Week

A critical buffer overflow vulnerability exists in Tenda AC10 routers (versions up to 15.03.06.47) in the PPTP server configuration handler that allows authenticated remote attackers to execute arbitrary code or cause denial of service. The vulnerability affects the startIp/endIp parameters in the /goform/SetPptpServerCfg HTTP endpoint, requires valid credentials but no user interaction, and has publicly disclosed exploit code available, making it actively exploitable in real-world deployments.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub VulDB
CVSS 3.1
8.8
EPSS
0.4%
CVE-2025-4896 HIGH This Month

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub VulDB
CVSS 4.0
8.7
EPSS
0.8%
CVE-2025-44175 MEDIUM POC This Month

Tenda AC10 v4 V16.03.10.13 is vulnerable to Buffer Overflow in the GetParentControlInfo function. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub
CVSS 3.1
5.4
EPSS
0.2%
CVE-2025-45779 CRITICAL POC Act Now

Tenda AC10 V1.0re_V15.03.06.46 is vulnerable to Buffer Overflow in the formSetPPTPUserList handler via the list POST parameter. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2025-25455 HIGH POC This Week

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via wanMTU2. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10 Firmware
NVD GitHub
CVSS 3.1
7.5
EPSS
0.4%
CVE-2025-25454 HIGH POC This Week

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via wanSpeed2. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10 Firmware
NVD GitHub
CVSS 3.1
7.5
EPSS
0.4%
CVE-2025-25457 HIGH POC This Week

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via cloneType2. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda Ac10 Firmware
NVD GitHub
CVSS 3.1
7.5
EPSS
0.4%
CVE-2025-25458 MEDIUM POC This Month

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serverName2. Rated medium severity (CVSS 4.6), this vulnerability is remotely exploitable. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub
CVSS 3.1
4.6
EPSS
0.2%
CVE-2025-25453 MEDIUM POC This Month

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serviceName2. Rated medium severity (CVSS 4.6), this vulnerability is remotely exploitable. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub
CVSS 3.1
4.6
EPSS
0.2%
CVE-2025-25456 CRITICAL POC Act Now

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via mac2. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
0.4%
CVE-2025-3161 HIGH This Week

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub VulDB
CVSS 4.0
8.7
EPSS
0.8%
CVE-2025-25675 CRITICAL Act Now

Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Command Injection Tenda Ac10 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
0.8%
CVE-2025-25674 CRITICAL Act Now

Tenda AC10 V1.0 V15.03.06.23 is vulnerable to Buffer Overflow in form_fast_setting_wifi_set via the parameter ssid. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
0.2%
CVE-2025-0528 HIGH POC This Week

A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Rated high severity (CVSS 8.6), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Command Injection Tenda Ac10 Firmware Ac18 Firmware Ac8 Firmware
NVD GitHub VulDB
CVSS 4.0
8.6
EPSS
0.9%
EPSS 0% CVSS 7.4
HIGH This Month

A vulnerability was determined in Tenda AC10 16.03.10.13. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD VulDB
EPSS 0% CVSS 5.3
MEDIUM This Month

An input validation flaw in the 'ate' service of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 to escalate privileges to root via a crafted UDP packet. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Privilege Escalation Tenda Ac10 Firmware
NVD
EPSS 0% CVSS 5.3
MEDIUM This Month

Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Tenda Ac10 Firmware
NVD
EPSS 0% CVSS 7.5
HIGH This Month

Tenda AC10 v4.0 firmware v16.03.10.20 was discovered to contain a stack overflow via the function get_parentControl_list_Info. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Stack Overflow Tenda +1
NVD
EPSS 0% CVSS 5.3
MEDIUM POC This Month

Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the security_5g parameter in the function sub_46284C. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +1
NVD
EPSS 0% CVSS 5.3
MEDIUM This Month

Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the Password parameter in the function R7WebsSecurityHandler. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Stack Overflow Tenda +1
NVD
EPSS 0% CVSS 8.8
HIGH This Week

A critical buffer overflow vulnerability exists in Tenda AC10 routers (versions up to 15.03.06.47) in the PPTP server configuration handler that allows authenticated remote attackers to execute arbitrary code or cause denial of service. The vulnerability affects the startIp/endIp parameters in the /goform/SetPptpServerCfg HTTP endpoint, requires valid credentials but no user interaction, and has publicly disclosed exploit code available, making it actively exploitable in real-world deployments.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub VulDB
EPSS 1% CVSS 8.7
HIGH This Month

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub VulDB
EPSS 0% CVSS 5.4
MEDIUM POC This Month

Tenda AC10 v4 V16.03.10.13 is vulnerable to Buffer Overflow in the GetParentControlInfo function. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC10 V1.0re_V15.03.06.46 is vulnerable to Buffer Overflow in the formSetPPTPUserList handler via the list POST parameter. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub
EPSS 0% CVSS 7.5
HIGH POC This Week

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via wanMTU2. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +1
NVD GitHub
EPSS 0% CVSS 7.5
HIGH POC This Week

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via wanSpeed2. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +1
NVD GitHub
EPSS 0% CVSS 7.5
HIGH POC This Week

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via cloneType2. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Stack Overflow Tenda +1
NVD GitHub
EPSS 0% CVSS 4.6
MEDIUM POC This Month

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serverName2. Rated medium severity (CVSS 4.6), this vulnerability is remotely exploitable. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub
EPSS 0% CVSS 4.6
MEDIUM POC This Month

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serviceName2. Rated medium severity (CVSS 4.6), this vulnerability is remotely exploitable. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub
EPSS 0% CVSS 9.8
CRITICAL POC Act Now

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via mac2. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub
EPSS 1% CVSS 8.7
HIGH This Week

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub VulDB
EPSS 1% CVSS 9.8
CRITICAL Act Now

Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Command Injection Tenda Ac10 Firmware
NVD GitHub
EPSS 0% CVSS 9.8
CRITICAL Act Now

Tenda AC10 V1.0 V15.03.06.23 is vulnerable to Buffer Overflow in form_fast_setting_wifi_set via the parameter ssid. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Ac10 Firmware
NVD GitHub
EPSS 1% CVSS 8.6
HIGH POC This Week

A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Rated high severity (CVSS 8.6), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Command Injection Tenda Ac10 Firmware +2
NVD GitHub VulDB

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy