Skip to main content

Ac9 Firmware

98 CVEs product

Monthly

CVE-2026-2192 Feb 08, 23:15 HIGH POC This Week

Stack buffer overflow in Tenda AC9 firmware versions up to 15.03.06.42_multi allows remote attackers to achieve code execution by manipulating scheduled reboot parameters without authentication. Public exploit code exists for this vulnerability, and no patch is currently available. The attack requires high privileges but succeeds over the network with minimal complexity.

Buffer Overflow Stack Overflow Ac9 Firmware
NVD GitHub VulDB
CVSS 3.1
7.2
EPSS
0.1%
CVE-2026-2191 Feb 08, 23:15 HIGH POC This Week

Stack overflow in Tenda AC9 firmware versions up to 15.03.06.42_multi allows remote attackers with high privileges to achieve complete system compromise through manipulation of the security.ddos.map parameter. Public exploit code exists for this vulnerability, increasing exploitation risk. No patch is currently available.

Buffer Overflow Stack Overflow Ac9 Firmware
NVD GitHub VulDB
CVSS 3.1
7.2
EPSS
0.1%
CVE-2025-57638 Sep 23, 19:15 HIGH POC This Week

Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Heap Overflow Buffer Overflow Tenda Ac9 Firmware
NVD GitHub
CVSS 3.1
7.5
EPSS
0.1%
CVE-2025-57639 Sep 23, 18:15 MEDIUM POC This Month

OS Command injection vulnerability in Tenda AC9 1.0 was discovered to contain a command injection vulnerability via the usb.samba.guest.user parameter in the formSetSambaConf function of the httpd. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Command Injection Tenda Ac9 Firmware
NVD GitHub
CVSS 3.1
6.5
EPSS
4.2%
CVE-2025-10443 Sep 15, 12:15 HIGH POC This Week

A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac9 Firmware Ac15 Firmware
NVD GitHub VulDB
CVSS 4.0
7.4
EPSS
0.5%
CVE-2025-5900 Jun 09, 22:15 LOW POC Monitor

Cross-site request forgery in Tenda AC9 router firmware 15.03.02.13 allows an attacker to trigger unintended actions like reboot or factory reset by tricking an authenticated admin into visiting a malicious page. Public exploit code exists, but no active exploitation has been confirmed.

Tenda CSRF Ac9 Firmware
NVD VulDB
CVSS 4.0
2.1
EPSS
0.1%
CVE-2025-5847 Jun 08, 14:15 HIGH POC This Week

Critical stack-based buffer overflow vulnerability in Tenda AC9 router firmware version 15.03.02.13, exploitable via the HTTP POST handler's formSetSafeWanWebMan function through manipulation of the remoteIp parameter. An authenticated remote attacker can achieve remote code execution with full system compromise (confidentiality, integrity, and availability impact). A public proof-of-concept exploit exists, elevating real-world exploitation risk significantly.

Buffer Overflow Ac9 Firmware Tenda
NVD VulDB
CVSS 3.1
8.8
EPSS
0.2%
CVE-2025-5839 Jun 07, 18:15 HIGH POC This Week

A critical buffer overflow vulnerability exists in Tenda AC9 router firmware version 15.03.02.13, affecting the POST request handler for LAN IP configuration. An authenticated attacker can exploit the lanMask parameter in the /goform/AdvSetLanip endpoint to trigger a buffer overflow, achieving remote code execution with full system compromise (confidentiality, integrity, and availability impact). Public exploit code is available and the vulnerability is actively exploitable with authenticated access.

Buffer Overflow Ac9 Firmware Tenda
NVD VulDB
CVSS 3.1
8.8
EPSS
0.2%
CVE-2025-5836 Jun 07, 14:15 LOW POC Monitor

Command injection in Tenda AC9 router firmware 15.03.02.13 allows remote authenticated attackers to execute arbitrary commands via the 'list' parameter in the formSetIptv handler. A public exploit is available, and EPSS score (2.05%, 84th percentile) indicates moderate exploitation likelihood, though no active exploitation in CISA KEV is reported.

Tenda Command Injection Ac9 Firmware
NVD VulDB
CVSS 4.0
2.1
EPSS
2.1%
CVE-2025-45042 May 05, 16:15 CRITICAL POC THREAT Emergency

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 14.8%.

Command Injection Tenda Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
14.8%
CVE-2025-44877 May 02, 15:15 CRITICAL POC THREAT Emergency

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via the usbname parameter. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 12.5%.

Command Injection Tenda Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
12.5%
CVE-2025-44872 May 02, 15:15 CRITICAL POC THREAT Emergency

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 12.5%.

Command Injection Tenda Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
12.5%
CVE-2025-45429 Apr 23, 16:15 CRITICAL POC Act Now

In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWpsStart, which may lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Buffer Overflow RCE Stack Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
2.4%
CVE-2025-45428 Apr 23, 15:16 CRITICAL POC Act Now

In Tenda ac9 v1.0 with firmware V15.03.05.14_multi, the rebootTime parameter of /goform/SetSysAutoRebbotCfg has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Buffer Overflow RCE Stack Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
2.2%
CVE-2025-45427 Apr 23, 15:16 CRITICAL POC Act Now

In Tenda AC9 v1.0 with firmware V15.03.05.14_multi, the security parameter of /goform/WifiBasicSet has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Buffer Overflow RCE Stack Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
2.2%
CVE-2025-29387 Mar 14, 17:15 HIGH POC This Week

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanSpeed parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Rated high severity (CVSS 7.1), this vulnerability is remotely exploitable. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow RCE Ac9 Firmware
NVD GitHub
CVSS 3.1
7.1
EPSS
0.5%
CVE-2025-29386 Mar 14, 17:15 CRITICAL POC Act Now

In Tenda AC9 v1.0 V15.03.05.14_multi, the mac parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow RCE Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.1%
CVE-2025-29385 Mar 14, 17:15 CRITICAL POC Act Now

In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow RCE Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.1%
CVE-2025-29384 Mar 14, 17:15 CRITICAL POC THREAT Emergency

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 14.6%.

Memory Corruption Tenda Buffer Overflow RCE Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
14.6%
CVE-2025-29032 Mar 14, 14:15 MEDIUM POC This Month

Tenda AC9 v15.03.05.19(6318) was discovered to contain a buffer overflow via the formWifiWpsOOB function. Rated medium severity (CVSS 5.9), this vulnerability is remotely exploitable. Public exploit code available and no vendor patch available.

Tenda Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
5.9
EPSS
0.1%
CVE-2025-22949 Jan 10, 16:15 CRITICAL POC Act Now

Tenda ac9 v1.0 firmware v15.03.05.19 is vulnerable to command injection in /goform/SetSambaCfg, which may lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RCE Command Injection Tenda Ac9 Firmware
NVD
CVSS 3.1
9.8
EPSS
8.2%
CVE-2025-22946 Jan 10, 15:15 CRITICAL POC Act Now

Tenda ac9 v1.0 firmware v15.03.05.19 contains a stack overflow vulnerability in /goform/SetOnlineDevName, which may lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RCE Tenda Buffer Overflow Ac9 Firmware
NVD
CVSS 3.1
9.8
EPSS
2.4%
CVE-2024-10280 Oct 23, 14:15 HIGH This Week

A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. Rated high severity (CVSS 7.1), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Null Pointer Dereference Tenda Denial Of Service Ac15 Firmware Ac7 Firmware +8
NVD GitHub VulDB
CVSS 4.0
7.1
EPSS
0.8%
CVE-2024-42634 Aug 16, 16:15 CRITICAL POC Act Now

A Command Injection vulnerability exists in formWriteFacMac of the httpd binary in Tenda AC9 v15.03.06.42. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Code Injection Command Injection Tenda RCE Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
2.2%
CVE-2024-25751 Feb 26, 22:15 CRITICAL Act Now

A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetSysTime function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Stack Overflow RCE Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.0%
CVE-2024-25756 Feb 22, 23:15 HIGH This Week

A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formWifiBasicSet function. Rated high severity (CVSS 8.0), this vulnerability is low attack complexity. No vendor patch available.

Buffer Overflow Tenda Stack Overflow RCE Ac9 Firmware
NVD GitHub
CVSS 3.1
8.0
EPSS
0.6%
CVE-2024-25753 Feb 22, 23:15 HIGH This Week

Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formSetDeviceName function. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Stack Overflow RCE Ac9 Firmware
NVD GitHub
CVSS 3.1
8.8
EPSS
0.6%
CVE-2024-25748 Feb 22, 23:15 HIGH This Week

A Stack Based Buffer Overflow vulnerability in tenda AC9 AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetIpMacBind function. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Stack Overflow RCE Ac9 Firmware
NVD GitHub
CVSS 3.1
8.8
EPSS
0.6%
CVE-2024-25746 Feb 22, 22:15 HIGH This Week

Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the add_white_node function. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Stack Overflow RCE Ac9 Firmware
NVD GitHub
CVSS 3.1
8.8
EPSS
0.4%
CVE-2024-24543 Feb 05, 21:15 CRITICAL POC Act Now

Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption RCE Tenda Denial Of Service +1
NVD GitHub
CVSS 3.1
9.8
EPSS
1.0%
CVE-2023-38823 Nov 20, 20:15 CRITICAL Act Now

Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow RCE Tenda Ac6 Firmware Ac9 Firmware +2
NVD GitHub
CVSS 3.1
9.8
EPSS
1.2%
CVE-2023-40942 Sep 07, 15:15 CRITICAL POC Act Now

Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/SetFirewallCfg. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-41563 Aug 30, 13:15 CRITICAL POC Act Now

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac9 Firmware Ac5 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-41562 Aug 30, 13:15 CRITICAL POC Act Now

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac9 Firmware Ac7 Firmware +1
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-41561 Aug 30, 13:15 CRITICAL POC Act Now

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac9 Firmware Ac5 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-41560 Aug 30, 13:15 CRITICAL POC Act Now

Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-41559 Aug 30, 13:15 CRITICAL POC Act Now

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac9 Firmware Ac7 Firmware +1
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-41556 Aug 30, 13:15 CRITICAL POC Act Now

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac9 Firmware Ac7 Firmware +1
NVD GitHub
CVSS 3.1
9.8
EPSS
0.9%
CVE-2023-41554 Aug 30, 13:15 CRITICAL POC Act Now

Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-41553 Aug 30, 13:15 CRITICAL POC Act Now

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac9 Firmware Ac5 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-41552 Aug 30, 13:15 CRITICAL POC Act Now

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac9 Firmware Ac7 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-38937 Aug 07, 19:15 CRITICAL POC Act Now

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac10 Firmware Ac1206 Firmware +5
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-38936 Aug 07, 19:15 CRITICAL POC Act Now

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac10 Firmware Ac1206 Firmware +7
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-38935 Aug 07, 19:15 CRITICAL POC Act Now

Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac1206 Firmware Ac5 Firmware +3
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-38933 Aug 07, 19:15 CRITICAL POC Act Now

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac10 Firmware Ac1206 Firmware +7
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-38930 Aug 07, 19:15 CRITICAL POC Act Now

Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac7 Firmware F1203 Firmware +3
NVD GitHub
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-37717 Jul 14, 00:15 CRITICAL POC Act Now

Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda F1202 Firmware Fh1202 Firmware +5
NVD GitHub
CVSS 3.1
9.8
EPSS
0.8%
CVE-2023-37716 Jul 14, 00:15 CRITICAL POC Act Now

Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda F1202 Firmware Fh1202 Firmware +5
NVD GitHub
CVSS 3.1
9.8
EPSS
0.8%
CVE-2022-36571 Aug 31, 20:15 HIGH POC This Week

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
7.2
EPSS
0.9%
CVE-2022-36570 Aug 31, 20:15 HIGH POC This Week

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
7.2
EPSS
0.9%
CVE-2022-36569 Aug 31, 20:15 HIGH POC This Week

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
8.8
EPSS
0.9%
CVE-2022-36568 Aug 31, 20:15 HIGH POC This Week

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
8.8
EPSS
0.9%
CVE-2022-36233 Aug 19, 22:15 MEDIUM POC This Month

Tenda AC9 V15.03.2.13 is vulnerable to Buffer Overflow via httpd, form_fast_setting_wifi_set. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Memory Corruption Ac9 Firmware
NVD VulDB
CVSS 3.1
5.5
EPSS
0.3%
CVE-2022-36273 Aug 16, 13:15 CRITICAL POC Act Now

Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Command Injection Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
2.4%
CVE-2022-28560 May 03, 16:15 CRITICAL POC Act Now

There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.6%
CVE-2022-27022 Apr 07, 16:15 CRITICAL POC Act Now

There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-27016 Apr 07, 15:15 CRITICAL POC Act Now

There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-26278 Mar 28, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-25441 Mar 18, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Command Injection Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
4.6%
CVE-2022-25440 Mar 18, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-25439 Mar 18, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-25438 Mar 18, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Command Injection Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
4.6%
CVE-2022-25437 Mar 18, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-25435 Mar 18, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-25434 Mar 18, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
9.1%
CVE-2022-25433 Mar 18, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-25431 Mar 18, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-25429 Mar 18, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-25428 Mar 18, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-25427 Mar 18, 21:15 CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-25418 Feb 24, 15:15 CRITICAL POC Act Now

Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-25417 Feb 24, 15:15 CRITICAL POC Act Now

Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
1.7%
CVE-2022-25414 Feb 24, 15:15 CRITICAL POC THREAT Act Now

Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the parameter NPTR. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow Ac9 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
10.4%
CVE-2021-31627 Oct 29, 11:15 HIGH POC This Week

Buffer Overflow vulnerability in Tenda AC9 V1.0 through V15.03.05.19(6318), and AC9 V3.0 V15.03.06.42_multi, allows attackers to execute arbitrary code via the index parameter. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow RCE Tenda Ac9 Firmware
NVD GitHub VulDB
CVSS 3.1
8.8
EPSS
1.2%
CVE-2021-31624 Oct 29, 11:15 HIGH POC This Week

Buffer Overflow vulnerability in Tenda AC9 V1.0 through V15.03.05.19(6318), and AC9 V3.0 V15.03.06.42_multi, allows attackers to execute arbitrary code via the urls parameter. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE Ac9 Firmware
NVD GitHub VulDB
CVSS 3.1
8.8
EPSS
1.2%
CVE-2020-13394 May 22, 17:15 CRITICAL POC Act Now

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE Ac6 Firmware Ac9 Firmware +2
NVD
CVSS 3.1
9.8
EPSS
2.6%
CVE-2020-13393 May 22, 17:15 CRITICAL POC Act Now

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE Ac6 Firmware Ac9 Firmware +2
NVD
CVSS 3.1
9.8
EPSS
3.3%
CVE-2020-13392 May 22, 17:15 CRITICAL POC Act Now

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE Ac6 Firmware Ac9 Firmware +2
NVD
CVSS 3.1
9.8
EPSS
2.6%
CVE-2020-13391 May 22, 17:15 CRITICAL POC Act Now

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE Ac6 Firmware Ac9 Firmware +2
NVD
CVSS 3.1
9.8
EPSS
2.6%
CVE-2020-13390 May 22, 17:15 CRITICAL POC Act Now

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE Ac6 Firmware Ac9 Firmware +2
NVD
CVSS 3.1
9.8
EPSS
2.6%
CVE-2020-13389 May 22, 17:15 CRITICAL POC Act Now

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE Ac6 Firmware Ac9 Firmware +2
NVD
CVSS 3.1
9.8
EPSS
2.6%
CVE-2018-14558 Oct 30, 18:29 CRITICAL POC KEV THREAT Act Now

An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Command Injection Ac7 Firmware Ac9 Firmware Ac10 Firmware
NVD GitHub
CVSS 3.1
9.8
EPSS
8.7%
CVE-2018-18732 Oct 29, 12:29 HIGH POC This Week

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware Ac9 Firmware Ac10 Firmware +2
NVD GitHub
CVSS 3.0
7.5
EPSS
1.1%
CVE-2018-18731 Oct 29, 12:29 HIGH POC This Week

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware Ac9 Firmware Ac10 Firmware +2
NVD GitHub
CVSS 3.0
7.5
EPSS
1.1%
CVE-2018-18730 Oct 29, 12:29 HIGH POC This Week

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware Ac9 Firmware Ac10 Firmware +2
NVD GitHub
CVSS 3.0
7.5
EPSS
1.1%
CVE-2018-18729 Oct 29, 12:29 CRITICAL POC Act Now

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda Ac7 Firmware Ac9 Firmware +3
NVD GitHub
CVSS 3.0
9.8
EPSS
1.3%
CVE-2018-18728 Oct 29, 12:29 CRITICAL POC Act Now

An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda RCE Command Injection Ac9 Firmware Ac15 Firmware +1
NVD GitHub
CVSS 3.0
9.8
EPSS
3.0%
CVE-2018-18727 Oct 29, 12:29 HIGH POC This Week

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware Ac9 Firmware Ac10 Firmware +2
NVD GitHub
CVSS 3.0
7.5
EPSS
1.1%
CVE-2018-18709 Oct 29, 12:29 HIGH POC This Week

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware Ac9 Firmware Ac10 Firmware +2
NVD GitHub
CVSS 3.0
7.5
EPSS
1.1%
CVE-2018-18708 Oct 29, 12:29 HIGH POC This Week

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware Ac9 Firmware Ac10 Firmware +2
NVD GitHub
CVSS 3.0
7.5
EPSS
1.4%
EPSS 0% CVSS 7.2
HIGH POC This Week

Stack buffer overflow in Tenda AC9 firmware versions up to 15.03.06.42_multi allows remote attackers to achieve code execution by manipulating scheduled reboot parameters without authentication. Public exploit code exists for this vulnerability, and no patch is currently available. The attack requires high privileges but succeeds over the network with minimal complexity.

Buffer Overflow Stack Overflow Ac9 Firmware
NVD GitHub VulDB
EPSS 0% CVSS 7.2
HIGH POC This Week

Stack overflow in Tenda AC9 firmware versions up to 15.03.06.42_multi allows remote attackers with high privileges to achieve complete system compromise through manipulation of the security.ddos.map parameter. Public exploit code exists for this vulnerability, increasing exploitation risk. No patch is currently available.

Buffer Overflow Stack Overflow Ac9 Firmware
NVD GitHub VulDB
EPSS 0% CVSS 7.5
HIGH POC This Week

Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Heap Overflow Buffer Overflow Tenda +1
NVD GitHub
EPSS 4% CVSS 6.5
MEDIUM POC This Month

OS Command injection vulnerability in Tenda AC9 1.0 was discovered to contain a command injection vulnerability via the usb.samba.guest.user parameter in the formSetSambaConf function of the httpd. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Command Injection Tenda Ac9 Firmware
NVD GitHub
EPSS 0% CVSS 7.4
HIGH POC This Week

A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac9 Firmware +1
NVD GitHub VulDB
EPSS 0% CVSS 2.1
LOW POC Monitor

Cross-site request forgery in Tenda AC9 router firmware 15.03.02.13 allows an attacker to trigger unintended actions like reboot or factory reset by tricking an authenticated admin into visiting a malicious page. Public exploit code exists, but no active exploitation has been confirmed.

Tenda CSRF Ac9 Firmware
NVD VulDB
EPSS 0% CVSS 8.8
HIGH POC This Week

Critical stack-based buffer overflow vulnerability in Tenda AC9 router firmware version 15.03.02.13, exploitable via the HTTP POST handler's formSetSafeWanWebMan function through manipulation of the remoteIp parameter. An authenticated remote attacker can achieve remote code execution with full system compromise (confidentiality, integrity, and availability impact). A public proof-of-concept exploit exists, elevating real-world exploitation risk significantly.

Buffer Overflow Ac9 Firmware Tenda
NVD VulDB
EPSS 0% CVSS 8.8
HIGH POC This Week

A critical buffer overflow vulnerability exists in Tenda AC9 router firmware version 15.03.02.13, affecting the POST request handler for LAN IP configuration. An authenticated attacker can exploit the lanMask parameter in the /goform/AdvSetLanip endpoint to trigger a buffer overflow, achieving remote code execution with full system compromise (confidentiality, integrity, and availability impact). Public exploit code is available and the vulnerability is actively exploitable with authenticated access.

Buffer Overflow Ac9 Firmware Tenda
NVD VulDB
EPSS 2% CVSS 2.1
LOW POC Monitor

Command injection in Tenda AC9 router firmware 15.03.02.13 allows remote authenticated attackers to execute arbitrary commands via the 'list' parameter in the formSetIptv handler. A public exploit is available, and EPSS score (2.05%, 84th percentile) indicates moderate exploitation likelihood, though no active exploitation in CISA KEV is reported.

Tenda Command Injection Ac9 Firmware
NVD VulDB
EPSS 15% CVSS 9.8
CRITICAL POC THREAT Emergency

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 14.8%.

Command Injection Tenda Ac9 Firmware
NVD GitHub
EPSS 13% CVSS 9.8
CRITICAL POC THREAT Emergency

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via the usbname parameter. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 12.5%.

Command Injection Tenda Ac9 Firmware
NVD GitHub
EPSS 13% CVSS 9.8
CRITICAL POC THREAT Emergency

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 12.5%.

Command Injection Tenda Ac9 Firmware
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWpsStart, which may lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Buffer Overflow RCE +2
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

In Tenda ac9 v1.0 with firmware V15.03.05.14_multi, the rebootTime parameter of /goform/SetSysAutoRebbotCfg has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Buffer Overflow RCE +2
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

In Tenda AC9 v1.0 with firmware V15.03.05.14_multi, the security parameter of /goform/WifiBasicSet has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Buffer Overflow RCE +2
NVD GitHub
EPSS 0% CVSS 7.1
HIGH POC This Week

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanSpeed parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Rated high severity (CVSS 7.1), this vulnerability is remotely exploitable. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

In Tenda AC9 v1.0 V15.03.05.14_multi, the mac parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow +2
NVD GitHub
EPSS 15% CVSS 9.8
CRITICAL POC THREAT Emergency

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 14.6%.

Memory Corruption Tenda Buffer Overflow +2
NVD GitHub
EPSS 0% CVSS 5.9
MEDIUM POC This Month

Tenda AC9 v15.03.05.19(6318) was discovered to contain a buffer overflow via the formWifiWpsOOB function. Rated medium severity (CVSS 5.9), this vulnerability is remotely exploitable. Public exploit code available and no vendor patch available.

Tenda Buffer Overflow Ac9 Firmware
NVD GitHub
EPSS 8% CVSS 9.8
CRITICAL POC Act Now

Tenda ac9 v1.0 firmware v15.03.05.19 is vulnerable to command injection in /goform/SetSambaCfg, which may lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RCE Command Injection Tenda +1
NVD
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda ac9 v1.0 firmware v15.03.05.19 contains a stack overflow vulnerability in /goform/SetOnlineDevName, which may lead to remote arbitrary code execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RCE Tenda Buffer Overflow +1
NVD
EPSS 1% CVSS 7.1
HIGH This Week

A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. Rated high severity (CVSS 7.1), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Null Pointer Dereference Tenda Denial Of Service +10
NVD GitHub VulDB
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

A Command Injection vulnerability exists in formWriteFacMac of the httpd binary in Tenda AC9 v15.03.06.42. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Code Injection Command Injection Tenda +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL Act Now

A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetSysTime function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Stack Overflow +2
NVD GitHub
EPSS 1% CVSS 8.0
HIGH This Week

A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formWifiBasicSet function. Rated high severity (CVSS 8.0), this vulnerability is low attack complexity. No vendor patch available.

Buffer Overflow Tenda Stack Overflow +2
NVD GitHub
EPSS 1% CVSS 8.8
HIGH This Week

Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formSetDeviceName function. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Stack Overflow +2
NVD GitHub
EPSS 1% CVSS 8.8
HIGH This Week

A Stack Based Buffer Overflow vulnerability in tenda AC9 AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetIpMacBind function. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Stack Overflow +2
NVD GitHub
EPSS 0% CVSS 8.8
HIGH This Week

Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the add_white_node function. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Tenda Stack Overflow +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Memory Corruption RCE +3
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL Act Now

Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow RCE Tenda +4
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/SetFirewallCfg. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +3
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +3
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +3
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +1
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +2
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +7
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +9
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +5
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +9
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +5
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +7
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +7
NVD GitHub
EPSS 1% CVSS 7.2
HIGH POC This Week

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow +1
NVD GitHub
EPSS 1% CVSS 7.2
HIGH POC This Week

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow +1
NVD GitHub
EPSS 1% CVSS 8.8
HIGH POC This Week

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow +1
NVD GitHub
EPSS 1% CVSS 8.8
HIGH POC This Week

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Tenda Buffer Overflow +1
NVD GitHub
EPSS 0% CVSS 5.5
MEDIUM POC This Month

Tenda AC9 V15.03.2.13 is vulnerable to Buffer Overflow via httpd, form_fast_setting_wifi_set. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Memory Corruption +1
NVD VulDB
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Command Injection Ac9 Firmware
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 5% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Command Injection Ac9 Firmware
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 5% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Command Injection Ac9 Firmware
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 9% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 10% CVSS 9.8
CRITICAL POC THREAT Act Now

Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the parameter NPTR. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Memory Corruption Buffer Overflow +1
NVD GitHub
EPSS 1% CVSS 8.8
HIGH POC This Week

Buffer Overflow vulnerability in Tenda AC9 V1.0 through V15.03.05.19(6318), and AC9 V3.0 V15.03.06.42_multi, allows attackers to execute arbitrary code via the index parameter. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow RCE Tenda +1
NVD GitHub VulDB
EPSS 1% CVSS 8.8
HIGH POC This Week

Buffer Overflow vulnerability in Tenda AC9 V1.0 through V15.03.05.19(6318), and AC9 V3.0 V15.03.06.42_multi, allows attackers to execute arbitrary code via the urls parameter. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE +1
NVD GitHub VulDB
EPSS 3% CVSS 9.8
CRITICAL POC Act Now

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE +4
NVD
EPSS 3% CVSS 9.8
CRITICAL POC Act Now

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE +4
NVD
EPSS 3% CVSS 9.8
CRITICAL POC Act Now

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE +4
NVD
EPSS 3% CVSS 9.8
CRITICAL POC Act Now

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE +4
NVD
EPSS 3% CVSS 9.8
CRITICAL POC Act Now

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE +4
NVD
EPSS 3% CVSS 9.8
CRITICAL POC Act Now

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda RCE +4
NVD
EPSS 9% CVSS 9.8
CRITICAL POC KEV THREAT Act Now

An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda Command Injection Ac7 Firmware +2
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware +4
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware +4
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware +4
NVD GitHub
EPSS 1% CVSS 9.8
CRITICAL POC Act Now

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Memory Corruption Buffer Overflow Tenda +5
NVD GitHub
EPSS 3% CVSS 9.8
CRITICAL POC Act Now

An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Tenda RCE Command Injection +3
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware +4
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware +4
NVD GitHub
EPSS 1% CVSS 7.5
HIGH POC This Week

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Buffer Overflow Tenda Ac7 Firmware +4
NVD GitHub
Page 1 of 2 Next

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy