Skip to main content

Ac9 Firmware CVE-2025-57638

HIGH
Heap-based Buffer Overflow (CWE-122)
2025-09-23 cve@mitre.org
7.5
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Heap buffer bounds checking
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 7.5 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available. EPSS exploitation probability: 0.08%.

Exploit ScenarioDerived

This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the high-severity affected system.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 28, 2026

Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-122. Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value. Affected products include: Tenda Ac9 Firmware.

Know when Ac9 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

2
PoC Detected
Sep 25, 2025 - 16:09 vuln.today
Public exploit code
CVE Published
Sep 23, 2025 - 19:15 nvd
HIGH 7.5

DescriptionCVE.org

Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value.

Executive ViewAI

Why It Matters

CVE-2025-57638 presents notable security risk, a heap-based buffer overflow vulnerability rated CVSS 7.5. Exploitation could allow attackers to corrupt memory, crash the application, or potentially execute arbitrary code. Proof-of-concept code is publicly available, increasing the risk of exploitation. Organizations should apply vendor updates when available and consider compensating controls in the interim.

Business Impact: High
Compensating Controls

Apply vendor patch. If immediate patching is not feasible: (1) Enable ASLR and DEP where available; (2) Implement network segmentation; (3) Monitor for exploitation indicators.

Threat Intelligence Overview

EPSS Score
0.1%
Top 77% exploitable
Exploit
POC
Public exploit code exists
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
High

Priority Score

58
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +38
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

A heap overflow occurs when a program writes data beyond the bounds of a buffer allocated in the heap memory region.

Affected Products (CPE)CVE.org

cpe:2.3:o:tenda:ac9_firmware:1.0:*:*:*:*:*:*:*
CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2025-45429 CRITICAL POC
9.8 Apr 23

In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWp

CVE-2025-45428 CRITICAL POC
9.8 Apr 23

In Tenda ac9 v1.0 with firmware V15.03.05.14_multi, the rebootTime parameter of /goform/SetSysAutoRebbotCfg has a stack

CVE-2025-45427 CRITICAL POC
9.8 Apr 23

In Tenda AC9 v1.0 with firmware V15.03.05.14_multi, the security parameter of /goform/WifiBasicSet has a stack overflow

CVE-2025-29386 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the mac parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, w

CVE-2025-29385 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerabil

CVE-2024-42634 CRITICAL POC
9.8 Aug 16

A Command Injection vulnerability exists in formWriteFacMac of the httpd binary in Tenda AC9 v15.03.06.42. Rated critica

CVE-2024-24543 CRITICAL POC
9.8 Feb 05

Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allo

CVE-2023-40942 CRITICAL POC
9.8 Sep 07

Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/Set

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy