Skip to main content

Ac9 Firmware CVE-2025-10443

HIGH
Buffer Overflow (CWE-119)
2025-09-15 cna@vuldb.com
7.4
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

3
Analysis Generated
Mar 28, 2026 - 19:12 vuln.today
PoC Detected
Sep 19, 2025 - 19:22 vuln.today
Public exploit code
CVE Published
Sep 15, 2025 - 12:15 nvd
HIGH 7.4

DescriptionCVE.org

A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. This vulnerability affects the function formexeCommand of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.

AnalysisAI

A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Buffer Overflow (CWE-119), which allows attackers to corrupt memory to execute arbitrary code or crash the application. A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. This vulnerability affects the function formexeCommand of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used. Affected products include: Tenda Ac9 Firmware, Tenda Ac15 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use memory-safe languages or bounds-checking. Enable ASLR, DEP/NX, stack canaries. Use safe string functions.

CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2025-45429 CRITICAL POC
9.8 Apr 23

In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWp

CVE-2025-45428 CRITICAL POC
9.8 Apr 23

In Tenda ac9 v1.0 with firmware V15.03.05.14_multi, the rebootTime parameter of /goform/SetSysAutoRebbotCfg has a stack

CVE-2025-45427 CRITICAL POC
9.8 Apr 23

In Tenda AC9 v1.0 with firmware V15.03.05.14_multi, the security parameter of /goform/WifiBasicSet has a stack overflow

CVE-2025-29386 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the mac parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, w

CVE-2025-29385 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerabil

CVE-2024-42634 CRITICAL POC
9.8 Aug 16

A Command Injection vulnerability exists in formWriteFacMac of the httpd binary in Tenda AC9 v15.03.06.42. Rated critica

CVE-2024-24543 CRITICAL POC
9.8 Feb 05

Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allo

CVE-2023-40942 CRITICAL POC
9.8 Sep 07

Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/Set

Share

CVE-2025-10443 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy