Ac15 Firmware
CVE-2024-2852
CRITICAL
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Stack buffer bounds checking
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available. |
| Exploit ScenarioDerived | This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the critical-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
A vulnerability was found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-121. A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda Ac15 Firmware.
Know when Ac15 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.
Affected Products (CPE)NVD
More in Ac15 Firmware
View allTenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se
Tenda AC15 router has a code injection in formsetUsbUnload (EPSS 1.7%) enabling unauthenticated remote code execution.
Tenda AC15 router has a command injection in formSetIptv (EPSS 1.1%) enabling unauthenticated root-level code execution.
Buffer overflow in Tenda AC15V1.0 via formSetMacFilterCfg. PoC available.
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Rated critical severity
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerabili
A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Rated critical severity (CVSS 9.8), this
A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8),
A vulnerability was found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerability is remote
A vulnerability was found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerability is remote
A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Rated critical severity (CVSS 9.8), t
A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Rated critical sever
NVD
CVE.org
EPSS
GitHub
VulDB
Exploit-DB