Skip to main content

Ac15 Firmware CVE-2026-24103

CRITICAL
Classic Buffer Overflow (CWE-120)
2026-03-03 cve@mitre.org
9.8
CVSS 3.1 · NVD
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Send crafted HTTP POST request to goform/formSetMacFilterCfg
  2. Exploit
    Trigger buffer overflow in MAC filter configuration parser
  3. Impact
    Execute arbitrary code with device privileges

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Buffer copy size validation
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

No special conditions — remote unauthenticated exploitation against Tenda AC15V1.0 running firmware V15.03.05.18_multi with default web interface enabled on port 80/443.

Impact

CVSS 9.8.

Exploit ScenarioDerived

Overflow via MAC filter configuration.

Act Now Prioritize within 24-48h. Why: CRITICAL severity + public POC available.
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 12, 2026

Buffer overflow in Tenda AC15V1.0 via formSetMacFilterCfg. PoC available.

Earlier versions of this analysis (1)
v1 Mar 12, 2026 - 22:05 CVSS 9.8

Buffer overflow in Tenda AC15 router.

RemediationAI

Update firmware.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

CWE-120.

Know when Ac15 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
PoC Detected
Mar 05, 2026 - 21:43 vuln.today
Public exploit code
CVE Published
Mar 03, 2026 - 15:16 nvd
CRITICAL 9.8

DescriptionCVE.org

A buffer overflow vulnerability was discovered in goform/formSetMacFilterCfg in Tenda AC15V1.0 V15.03.05.18_multi.

Executive ViewAI

Why It Matters

A critical buffer overflow vulnerability (CVSS 9.8) affects Tenda AC15 routers, allowing unauthenticated remote code execution with no available patch. Organizations using this hardware face immediate risk of complete system compromise, data theft, and network infiltration without urgent mitigation.

Business Impact: Severe
Compensating Controls

Disable remote management interfaces and restrict access to device administration ports (typically 80/443, 8080) using firewall rules and network ACLs. Implement WAF rules to block requests to /goform/formSetMacFilterCfg endpoints. Segment affected routers to isolated networks with no external internet access. Monitor for suspicious traffic patterns and exploitation attempts. Upgrade to alternative router firmware or hardware from vendors with active security support.

Threat Intelligence Overview

EPSS Score
0.1%
Top 84% exploitable
Exploit
POC
Public exploit code exists
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC Yes
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
CRITICAL severity + public POC available
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
Very High

Priority Score

69
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +49
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

Affected Products (CPE)CVE.org

cpe:2.3:o:tenda:ac15_firmware:15.03.05.18_multi:*:*:*:*:*:*:*
CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2026-24105 CRITICAL POC
9.8 Mar 02

Tenda AC15 router has a code injection in formsetUsbUnload (EPSS 1.7%) enabling unauthenticated remote code execution.

CVE-2026-24101 CRITICAL POC
9.8 Mar 02

Tenda AC15 router has a command injection in formSetIptv (EPSS 1.1%) enabling unauthenticated root-level code execution.

CVE-2024-2855 CRITICAL POC
9.8 Mar 24

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Rated critical severity

CVE-2024-2852 CRITICAL POC
9.8 Mar 24

A vulnerability was found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerability is remote

CVE-2024-2851 CRITICAL POC
9.8 Mar 24

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerabili

CVE-2024-2850 CRITICAL POC
9.8 Mar 24

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Rated critical severity (CVSS 9.8), this

CVE-2024-2815 CRITICAL POC
9.8 Mar 22

A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8),

CVE-2024-2814 CRITICAL POC
9.8 Mar 22

A vulnerability was found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerability is remote

CVE-2024-2813 CRITICAL POC
9.8 Mar 22

A vulnerability was found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerability is remote

CVE-2024-2811 CRITICAL POC
9.8 Mar 22

A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Rated critical severity (CVSS 9.8), t

CVE-2024-2810 CRITICAL POC
9.8 Mar 22

A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Rated critical sever

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy