Skip to main content

Ac15 Firmware CVE-2026-24103

CRITICAL
Classic Buffer Overflow (CWE-120)
2026-03-03 cve@mitre.org
9.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

3
Analysis Generated
Mar 12, 2026 - 22:05 vuln.today
PoC Detected
Mar 05, 2026 - 21:43 vuln.today
Public exploit code
CVE Published
Mar 03, 2026 - 15:16 nvd
CRITICAL 9.8

DescriptionCVE.org

A buffer overflow vulnerability was discovered in goform/formSetMacFilterCfg in Tenda AC15V1.0 V15.03.05.18_multi.

AnalysisAI

Buffer overflow in Tenda AC15V1.0 via formSetMacFilterCfg. PoC available.

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
Send crafted HTTP POST request to goform/formSetMacFilterCfg
Exploit
Trigger buffer overflow in MAC filter configuration parser
Impact
Execute arbitrary code with device privileges

Vulnerability AssessmentAI

Exploitation No special conditions — remote unauthenticated exploitation against Tenda AC15V1.0 running firmware V15.03.05.18_multi with default web interface enabled on port 80/443. Additional conditions and limiting factors are described in the full assessment.
Risk Assessment CVSS 9.8. Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Overflow via MAC filter configuration.
Remediation Update firmware. Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours: Inventory all Tenda AC15V1.0 devices running V15.03.05.18_multi firmware and isolate affected units from production networks if business-critical. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

CVE-2026-24103 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy