Medtronic

30 CVEs vendor

Monthly

CVE-2025-4397 May 07, 15:03 MEDIUM This Month

Medtronic MyCareLink Patient Monitor stores per-product credentials in a recoverable (non-hashed or weakly encrypted) format, allowing physical attackers with device access to extract these credentials and modify encrypted drive data without authentication. Affected models include the 24950 and 24952 monitors. The vulnerability requires physical access to the device (CVSS AV:P) but grants full confidentiality, integrity, and availability impact to stored patient data.

Information Disclosure Mycarelink Patient Monitor 24950 Mycarelink Patient Monitor 24952 Medtronic
NVD
CVSS 3.1
6.8
EPSS
0.0%
CVE-2025-4386 May 07, 15:00 MEDIUM This Month

Medtronic MyCareLink Patient Monitor models 24950 and 24952 expose an unauthenticated UART login prompt via an internal serial interface, allowing attackers with physical access to potentially gain administrative control without authentication. The vulnerability achieves high confidentiality, integrity, and availability impact (CVSS 6.8) but requires direct physical access to internal hardware connections, limiting real-world exploitation to scenarios involving device tampering or insider threats.

Information Disclosure Mycarelink Patient Monitor 24950 Mycarelink Patient Monitor 24952 Medtronic
NVD
CVSS 3.1
6.8
EPSS
0.0%
CVE-2025-12997 Dec 04, 20:16 LOW Monitor

Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API endpoint that would expose sensitive user information. This issue affects CareLink Network: before December 4, 2025.

Authentication Bypass Carelink Network Medtronic
NVD
CVSS 3.1
2.2
EPSS
0.0%
CVE-2025-12996 Dec 04, 20:16 MEDIUM This Month

Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under certain circumstances. This issue affects CareLink Network: before December 4, 2025.

Information Disclosure Carelink Network Medtronic
NVD
CVSS 3.1
4.1
EPSS
0.0%
CVE-2025-12995 Dec 04, 20:16 HIGH This Week

Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: before December 4, 2025.

Information Disclosure Carelink Network Medtronic
NVD
CVSS 3.1
8.1
EPSS
0.1%
CVE-2025-12994 Dec 04, 20:16 MEDIUM This Month

A security vulnerability in Medtronic CareLink Network (CVSS 5.3) that allows an unauthenticated remote attacker. Remediation should follow standard vulnerability management procedures.

Information Disclosure Carelink Network Medtronic
NVD
CVSS 3.1
5.3
EPSS
0.1%
CVE-2023-31222 Jun 29, 16:15 HIGH This Week

Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Deserialization Microsoft Paceart Optima Medtronic
NVD
CVSS 3.1
8.8
EPSS
28.3%
CVE-2023-25931 Mar 01, 19:15 MEDIUM This Month

Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Rated medium severity (CVSS 6.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Interstim X Clinician Micro Clinician Medtronic
NVD
CVSS 3.1
6.8
EPSS
0.3%
CVE-2022-32537 Dec 12, 13:15 MEDIUM This Month

A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system. Rated medium severity (CVSS 4.8). No vendor patch available.

Authentication Bypass Guardian Link 2 Transmitter Mmt 7730 Firmware Guardian Link 2 Transmitter Mmt 7731 Firmware Guardian Link 2 Transmitter Mmt 7738 Firmware Guardian Link 2 Transmitter Mmt 7775 Firmware +25
NVD
CVSS 3.1
4.8
EPSS
0.1%
CVE-2020-27252 Dec 14, 20:15 HIGH This Week

Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient. Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Information Disclosure Mycarelink Smart Model 25000 Firmware Medtronic
NVD
CVSS 3.1
8.1
EPSS
3.7%
CVE-2020-25187 Dec 14, 20:15 CRITICAL Act Now

Medtronic MyCareLink Smart 25000 is vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Heap Overflow Mycarelink Smart Model 25000 Firmware Medtronic
NVD
CVSS 3.1
9.8
EPSS
3.8%
CVE-2020-25183 Dec 14, 20:15 HIGH This Week

Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Mycarelink Smart Model 25000 Firmware Medtronic
NVD
CVSS 3.1
8.8
EPSS
0.8%
CVE-2019-13543 Nov 08, 20:15 HIGH This Week

Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Microsoft Valleylab Ft10 Energy Platform Firmware Valleylab Exchange Client Valleylab Fx8 Energy Platform Firmware +1
NVD
CVSS 3.1
7.5
EPSS
2.0%
CVE-2019-13539 Nov 08, 20:15 HIGH This Week

Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.

Information Disclosure Microsoft Valleylab Ft10 Energy Platform Firmware Valleylab Exchange Client Valleylab Fx8 Energy Platform Firmware +1
NVD
CVSS 3.1
7.8
EPSS
0.3%
CVE-2019-13535 Nov 08, 20:15 MEDIUM This Month

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN-not available in the United States) version. Rated medium severity (CVSS 4.6), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Valleylab Ft10 Energy Platform Firmware Valleylab Ls10 Energy Platform Firmware Medtronic
NVD
CVSS 3.1
4.6
EPSS
0.4%
CVE-2019-13531 Nov 08, 20:15 MEDIUM This Month

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN-not available in the United States) version. Rated medium severity (CVSS 4.6), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Valleylab Ft10 Energy Platform Firmware Valleylab Ls10 Energy Platform Firmware Medtronic
NVD
CVSS 3.1
4.6
EPSS
0.4%
CVE-2019-10964 Jun 28, 21:15 HIGH This Week

Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. Rated high severity (CVSS 7.1), this vulnerability is no authentication required. No vendor patch available.

Authentication Bypass Minimed 508 Firmware Minimed Paradigm 511 Firmware Minimed Paradigm 512 Firmware Minimed Paradigm 712 Firmware +16
NVD
CVSS 3.1
7.1
EPSS
1.2%
CVE-2019-6540 Mar 26, 18:29 MEDIUM This Month

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Carelink 2090 Firmware Amplia Crt D Firmware Claria Crt D Firmware Compia Crt D Firmware +20
NVD
CVSS 3.1
6.5
EPSS
0.2%
CVE-2019-6538 Mar 25, 22:29 MEDIUM This Month

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Mycarelink Monitor Firmware Carelink Monitor Firmware Carelink 2090 Firmware Amplia Crt D Firmware +17
NVD
CVSS 3.1
6.5
EPSS
0.8%
CVE-2018-18984 Dec 14, 15:29 MEDIUM This Month

Medtronic CareLink and Encore Programmers do not encrypt or do not sufficiently encrypt sensitive PII and PHI information while at rest . Rated medium severity (CVSS 4.6), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Carelink 2090 Programmer Firmware Carelink 9790 Programmer Firmware 29901 Encore Programmer Firmware Medtronic
NVD
CVSS 3.1
4.6
EPSS
0.3%
CVE-2018-10634 Aug 13, 21:47 MEDIUM This Month

Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. Rated medium severity (CVSS 4.8), this vulnerability is no authentication required. No vendor patch available.

Information Disclosure Minimed Paradigm Revel Mmt 523K Firmware Minimed Paradigm Revel Mmt 723K Firmware Minimed Paradigm Revel Mmt 723 Firmware Minimed 530G Mmt 551 Firmware +6
NVD
CVSS 3.1
4.8
EPSS
0.5%
CVE-2018-10626 Aug 10, 18:29 MEDIUM This Month

Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. Rated medium severity (CVSS 4.4). No vendor patch available.

Information Disclosure Mycarelink 24952 Patient Monitor Firmware Mycarelink 24950 Patient Monitor Firmware Medtronic
NVD GitHub VulDB
CVSS 3.1
4.4
EPSS
0.0%
CVE-2018-10622 Aug 10, 18:29 MEDIUM This Month

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. Rated medium severity (CVSS 5.2), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Mycarelink 24952 Patient Monitor Firmware Mycarelink 24950 Patient Monitor Firmware Medtronic
NVD GitHub VulDB
CVSS 3.1
5.2
EPSS
0.1%
CVE-2018-10631 Jul 13, 19:29 MEDIUM This Month

The 8840 Clinician Programmer executes the application program from the 8870 Application Card. Rated medium severity (CVSS 6.3), this vulnerability is no authentication required. No vendor patch available.

Authentication Bypass N Vision 8840 Firmware N Vision 8870 Firmware Medtronic
NVD
CVSS 3.1
6.3
EPSS
0.4%
CVE-2018-8870 Jul 03, 01:29 MEDIUM This Month

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. Rated medium severity (CVSS 6.4), this vulnerability is no authentication required. No vendor patch available.

Authentication Bypass 24950 Mycarelink Monitor Firmware 24952 Mycarelink Monitor Firmware Medtronic
NVD
CVSS 3.1
6.4
EPSS
0.4%
CVE-2018-8868 Jul 03, 01:29 MEDIUM This Month

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the. Rated medium severity (CVSS 6.2). No vendor patch available.

RCE 24950 Mycarelink Monitor Firmware 24952 Mycarelink Monitor Firmware Medtronic
NVD
CVSS 3.1
6.2
EPSS
0.3%
CVE-2018-10596 Jul 03, 01:29 HIGH This Week

Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates. Rated high severity (CVSS 7.1), this vulnerability is remotely exploitable. No vendor patch available.

Information Disclosure 2090 Carelink Programmer Firmware Medtronic
NVD
CVSS 3.1
7.1
EPSS
1.3%
CVE-2018-8849 May 18, 13:29 MEDIUM This Month

Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programme and 8870 N'Vision removable Application Card do not encrypt PII and PHI while at rest. Rated medium severity (CVSS 4.6), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure N Vision 8840 Firmware N Vision 8870 Firmware Medtronic
NVD
CVSS 3.1
4.6
EPSS
0.3%
CVE-2018-5448 May 04, 18:29 MEDIUM This Month

Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the system. Rated medium severity (CVSS 4.8). No vendor patch available.

Path Traversal 2090 Carelink Programmer Firmware Medtronic
NVD
CVSS 3.1
4.8
EPSS
0.7%
CVE-2018-5446 May 04, 18:29 MEDIUM This Month

Medtronic 2090 CareLink Programmer uses a per-product username and password that is stored in a recoverable format. Rated medium severity (CVSS 4.9), this vulnerability is no authentication required. No vendor patch available.

Information Disclosure 2090 Carelink Programmer Firmware Medtronic
NVD
CVSS 3.1
4.9
EPSS
0.4%
EPSS 0% CVSS 6.8
MEDIUM This Month

Medtronic MyCareLink Patient Monitor stores per-product credentials in a recoverable (non-hashed or weakly encrypted) format, allowing physical attackers with device access to extract these credentials and modify encrypted drive data without authentication. Affected models include the 24950 and 24952 monitors. The vulnerability requires physical access to the device (CVSS AV:P) but grants full confidentiality, integrity, and availability impact to stored patient data.

Information Disclosure Mycarelink Patient Monitor 24950 Mycarelink Patient Monitor 24952 +1
NVD
EPSS 0% CVSS 6.8
MEDIUM This Month

Medtronic MyCareLink Patient Monitor models 24950 and 24952 expose an unauthenticated UART login prompt via an internal serial interface, allowing attackers with physical access to potentially gain administrative control without authentication. The vulnerability achieves high confidentiality, integrity, and availability impact (CVSS 6.8) but requires direct physical access to internal hardware connections, limiting real-world exploitation to scenarios involving device tampering or insider threats.

Information Disclosure Mycarelink Patient Monitor 24950 Mycarelink Patient Monitor 24952 +1
NVD
EPSS 0% CVSS 2.2
LOW Monitor

Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API endpoint that would expose sensitive user information. This issue affects CareLink Network: before December 4, 2025.

Authentication Bypass Carelink Network Medtronic
NVD
EPSS 0% CVSS 4.1
MEDIUM This Month

Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under certain circumstances. This issue affects CareLink Network: before December 4, 2025.

Information Disclosure Carelink Network Medtronic
NVD
EPSS 0% CVSS 8.1
HIGH This Week

Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: before December 4, 2025.

Information Disclosure Carelink Network Medtronic
NVD
EPSS 0% CVSS 5.3
MEDIUM This Month

A security vulnerability in Medtronic CareLink Network (CVSS 5.3) that allows an unauthenticated remote attacker. Remediation should follow standard vulnerability management procedures.

Information Disclosure Carelink Network Medtronic
NVD
EPSS 28% CVSS 8.8
HIGH This Week

Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Deserialization Microsoft Paceart Optima +1
NVD
EPSS 0% CVSS 6.8
MEDIUM This Month

Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Rated medium severity (CVSS 6.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Interstim X Clinician Micro Clinician +1
NVD
EPSS 0% CVSS 4.8
MEDIUM This Month

A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system. Rated medium severity (CVSS 4.8). No vendor patch available.

Authentication Bypass Guardian Link 2 Transmitter Mmt 7730 Firmware Guardian Link 2 Transmitter Mmt 7731 Firmware +27
NVD
EPSS 4% CVSS 8.1
HIGH This Week

Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient. Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Information Disclosure Mycarelink Smart Model 25000 Firmware Medtronic
NVD
EPSS 4% CVSS 9.8
CRITICAL Act Now

Medtronic MyCareLink Smart 25000 is vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Heap Overflow Mycarelink Smart Model 25000 Firmware +1
NVD
EPSS 1% CVSS 8.8
HIGH This Week

Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Mycarelink Smart Model 25000 Firmware Medtronic
NVD
EPSS 2% CVSS 7.5
HIGH This Week

Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Microsoft Valleylab Ft10 Energy Platform Firmware +3
NVD
EPSS 0% CVSS 7.8
HIGH This Week

Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.

Information Disclosure Microsoft Valleylab Ft10 Energy Platform Firmware +3
NVD
EPSS 0% CVSS 4.6
MEDIUM This Month

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN-not available in the United States) version. Rated medium severity (CVSS 4.6), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Valleylab Ft10 Energy Platform Firmware Valleylab Ls10 Energy Platform Firmware +1
NVD
EPSS 0% CVSS 4.6
MEDIUM This Month

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN-not available in the United States) version. Rated medium severity (CVSS 4.6), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Valleylab Ft10 Energy Platform Firmware Valleylab Ls10 Energy Platform Firmware +1
NVD
EPSS 1% CVSS 7.1
HIGH This Week

Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. Rated high severity (CVSS 7.1), this vulnerability is no authentication required. No vendor patch available.

Authentication Bypass Minimed 508 Firmware Minimed Paradigm 511 Firmware +18
NVD
EPSS 0% CVSS 6.5
MEDIUM This Month

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Carelink 2090 Firmware Amplia Crt D Firmware +22
NVD
EPSS 1% CVSS 6.5
MEDIUM This Month

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Mycarelink Monitor Firmware Carelink Monitor Firmware +19
NVD
EPSS 0% CVSS 4.6
MEDIUM This Month

Medtronic CareLink and Encore Programmers do not encrypt or do not sufficiently encrypt sensitive PII and PHI information while at rest . Rated medium severity (CVSS 4.6), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Carelink 2090 Programmer Firmware Carelink 9790 Programmer Firmware +2
NVD
EPSS 0% CVSS 4.8
MEDIUM This Month

Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. Rated medium severity (CVSS 4.8), this vulnerability is no authentication required. No vendor patch available.

Information Disclosure Minimed Paradigm Revel Mmt 523K Firmware Minimed Paradigm Revel Mmt 723K Firmware +8
NVD
EPSS 0% CVSS 4.4
MEDIUM This Month

Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. Rated medium severity (CVSS 4.4). No vendor patch available.

Information Disclosure Mycarelink 24952 Patient Monitor Firmware Mycarelink 24950 Patient Monitor Firmware +1
NVD GitHub VulDB
EPSS 0% CVSS 5.2
MEDIUM This Month

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. Rated medium severity (CVSS 5.2), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Mycarelink 24952 Patient Monitor Firmware Mycarelink 24950 Patient Monitor Firmware +1
NVD GitHub VulDB
EPSS 0% CVSS 6.3
MEDIUM This Month

The 8840 Clinician Programmer executes the application program from the 8870 Application Card. Rated medium severity (CVSS 6.3), this vulnerability is no authentication required. No vendor patch available.

Authentication Bypass N Vision 8840 Firmware N Vision 8870 Firmware +1
NVD
EPSS 0% CVSS 6.4
MEDIUM This Month

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. Rated medium severity (CVSS 6.4), this vulnerability is no authentication required. No vendor patch available.

Authentication Bypass 24950 Mycarelink Monitor Firmware 24952 Mycarelink Monitor Firmware +1
NVD
EPSS 0% CVSS 6.2
MEDIUM This Month

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the. Rated medium severity (CVSS 6.2). No vendor patch available.

RCE 24950 Mycarelink Monitor Firmware 24952 Mycarelink Monitor Firmware +1
NVD
EPSS 1% CVSS 7.1
HIGH This Week

Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates. Rated high severity (CVSS 7.1), this vulnerability is remotely exploitable. No vendor patch available.

Information Disclosure 2090 Carelink Programmer Firmware Medtronic
NVD
EPSS 0% CVSS 4.6
MEDIUM This Month

Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programme and 8870 N'Vision removable Application Card do not encrypt PII and PHI while at rest. Rated medium severity (CVSS 4.6), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure N Vision 8840 Firmware N Vision 8870 Firmware +1
NVD
EPSS 1% CVSS 4.8
MEDIUM This Month

Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the system. Rated medium severity (CVSS 4.8). No vendor patch available.

Path Traversal 2090 Carelink Programmer Firmware Medtronic
NVD
EPSS 0% CVSS 4.9
MEDIUM This Month

Medtronic 2090 CareLink Programmer uses a per-product username and password that is stored in a recoverable format. Rated medium severity (CVSS 4.9), this vulnerability is no authentication required. No vendor patch available.

Information Disclosure 2090 Carelink Programmer Firmware Medtronic
NVD