Mycarelink 24952 Patient Monitor Firmware
CVE-2018-10626
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A08:2025 - Software or Data Integrity Failures
ASVS 5.0
V15 - Secure Coding and Architecture Data authenticity verification
|
| Impact | CVSS score of 4.4 (MEDIUM). Attack characteristics: adjacent network attack vector, high complexity, low privileges required, no user interaction not required. EPSS exploitation probability: 0.04%. |
| Exploit ScenarioDerived | Successful exploitation could compromise the medium-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. Rated medium severity (CVSS 4.4). No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-345. Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network. Affected products include: Medtronic Mycarelink 24952 Patient Monitor Firmware, Medtronic Mycarelink 24950 Patient Monitor Firmware.
Know when Mycarelink 24952 Patient Monitor Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionCVE.org
Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
NVD
CVE.org
EPSS
GitHub
VulDB
Exploit-DB