Skip to main content

24950 Mycarelink Monitor Firmware CVE-2018-8868

MEDIUM
Exposed Dangerous Method or Function (CWE-749)
2018-07-03 ics-cert@hq.dhs.gov
6.2
CVSS 3.1 · Vendor: hq
Share

Severity by source

Vendor (hq) PRIMARY
6.2 MEDIUM
AV:P/AC:H/PR:L/UI:N/S:C/C:H/I:L/A:L

Primary rating from Vendor (hq) · only source for this CVE.

CVSS VectorVendor: hq

CVSS:3.1/AV:P/AC:H/PR:L/UI:N/S:C/C:H/I:L/A:L
Attack Vector
Physical
Attack Complexity
High
Privileges Required
Low
User Interaction
None
Scope
Changed
Confidentiality
High
Integrity
Low
Availability
Low

Lifecycle Timeline

1
CVE Published
Jul 03, 2018 - 01:29 cve.org
MEDIUM 6.2

DescriptionCVE.org

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.

AnalysisAI

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the. Rated medium severity (CVSS 6.2). No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-749. Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality. Affected products include: Medtronic 24950 Mycarelink Monitor Firmware, Medtronic 24952 Mycarelink Monitor Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2018-8868 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy