Skip to main content

CONPROSYS HMI System EUVDEUVD-2026-77243

| CVE-2026-82789 HIGH
Eval Injection (CWE-95)
2026-09-14 jpcert GHSA-6c68-h54j-7c3w
8.7
CVSS 4.0 · Vendor: jpcert
Share

Severity by source

Vendor (jpcert) PRIMARY
8.7 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
8.8 HIGH

Network-reachable eval injection requiring only a low-privilege login; no scope change since impact is confined to the CHS application system.

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (jpcert).

CVSS VectorVendor: jpcert

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

4
Patch available
Sep 14, 2026 - 08:01 EUVD
Analysis Generated
Sep 14, 2026 - 07:26 vuln.today
CVSS changed
Sep 14, 2026 - 07:22 NVD
8.8 (HIGH) 8.7 (HIGH)
CVE Published
Sep 14, 2026 - 06:44 cve.org
HIGH 8.7

DescriptionCVE.org

An improper neutralization of directives in dynamically evaluated code ('Eval Injection') issue exists in CONPROSYS HMI System(CHS). If exploited, arbitrary code may be executed by an attacker who can log in to the product.

AnalysisAI

Eval injection in CONPROSYS HMI System (CHS) by Contec allows authenticated network attackers to execute arbitrary code on the server hosting the HMI application. The flaw (CWE-95) occurs when user-supplied input reaches a dynamic code evaluation function without proper neutralization, enabling full server-side code execution. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Persist
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Exploitation requires a valid login to the CONPROSYS HMI System (CHS) web interface - at minimum a low-privilege account (CVSS PR:L). … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The provided CVSS 4.0 score of 8.7 (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H) accurately reflects real-world risk - the single meaningful constraint is authentication (PR:L), meaning an attacker must hold a valid account. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation Upgrade CONPROSYS HMI System (CHS) to the fixed version specified in Contec's security advisory (https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_cps_26091000_en.pdf) - the exact patched version number is not independently confirmed from the available data and must be obtained from the vendor. … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours, inventory all systems running CONPROSYS HMI System and restrict network access to HMI servers from untrusted networks-limit connectivity to authenticated internal users only and disable unnecessary network services. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

EUVD-2026-77243 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy