Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessCraft malformed PSM file
-
DeliveryDeliver via email or file-sharing platform
-
ExploitVictim opens file in Solid Edge
-
ExecutionTrigger out-of-bounds write in PSM parser
-
ImpactExecute arbitrary code as current user
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, write limits
MITRE ATT&CK
2 techniques across 2 tactics: Execution, Privilege Escalation The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires that a victim user actively open a specially crafted PSM file within an affected version of Siemens Solid Edge (SE2025 prior to V225.0 Update 15, or SE2026 prior to V226.0 Update 7). The attack vector is local (AV:L per the CVSS 4.0 vector), meaning the malicious file must be accessible on or mounted to the victim's filesystem - direct remote exploitation without a prior file-delivery step is not possible. Passive user interaction is required (UI:P); the attack cannot proceed without the victim choosing to open the file in Solid Edge. Attack complexity is rated high (AC:H), indicating the exploit likely depends on specific memory layout or timing conditions that may reduce reliability. No elevated privileges are required to craft or deliver the file (PR:N). Exploitation is scoped to the Solid Edge process; it does not affect the broader system or other applications (SC:N). Limiting factors include: the mandatory user-interaction step, high attack complexity, and the requirement that the victim be running an unpatched Solid Edge release. |
| Impact | The CVSS 4.0 vector (AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N) characterises this as a local-vector, high-complexity flaw requiring passive user interaction, which materially constrains opportunistic and automated exploitation - a mass-scale campaign is implausible given these preconditions. Impact metrics VC:H/VI:H/VA:H indicate full compromise of the Solid Edge process, but the unchanged scope (SC:N/SI:N/SA:N) limits blast radius to the application and its data. No CISA KEV listing and no public exploit have been identified, and no EPSS score was provided, leaving probabilistic exploitation likelihood unquantified. The high attack complexity rating is a genuine mitigating factor and suggests reliable weaponisation would require significant reverse-engineering effort. That said, even a mid-sized engineering team in Legnica that routinely exchanges Solid Edge PSM files with external suppliers operates in a realistic threat environment - design-file phishing is a documented industrial espionage vector - and the potential for intellectual property theft or process sabotage justifies treating this as a priority patching item. The CVSS vector and description are consistent with each other; no conflicting signals were detected. |
| Exploit ScenarioDerived | An attacker crafts a malformed PSM file engineered to corrupt heap or stack memory in Solid Edge's parser and delivers it to a target engineer disguised as a legitimate design file - via email, a project collaboration portal, or a removable drive. When the victim opens the file in an unpatched version of Solid Edge SE2025 or SE2026, the out-of-bounds write overwrites critical memory structures, redirecting execution to attacker-controlled code running with the privileges of the logged-in user. No public proof-of-concept exploit has been identified at time of analysis, meaning a working exploit would currently require independent vulnerability research to develop. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv3 – Aug 11, 2026
Out-of-bounds write in Siemens Solid Edge SE2025 and SE2026 enables code execution within the application's process when a user opens a specially crafted PSM part model file. Affected versions are SE2025 prior to V225.0 Update 15 and SE2026 prior to V226.0 Update 7, confirmed by Siemens PSIRT via advisory SSA-621657. No public exploit has been identified at time of analysis, and the vulnerability does not appear in the CISA KEV catalog.
Earlier versions of this analysis (2)
Out-of-bounds write in the PSM file parser of Siemens Solid Edge SE2025 and SE2026 enables arbitrary code execution in the context of the running process when a user opens a specially crafted part file. All versions of SE2025 prior to V225.0 Update 15 and SE2026 prior to V226.0 Update 7 are confirmed affected per Siemens Security Advisory SSA-621657. No public exploit or active exploitation has been identified at time of analysis; Siemens has released patched updates for both product lines.
Out-of-bounds write in Siemens Solid Edge SE2025 (all versions before V225.0 Update 15) and SE2026 (all versions before V226.0 Update 7) enables arbitrary code execution when a victim opens a specially crafted PSM part model file within the application. The root cause is insufficient bounds validation during PSM file parsing, a CWE-787 class flaw, causing memory corruption that can redirect execution flow to attacker-controlled code running under the current process context. Siemens has released patched versions via advisory SSA-621657; no public exploit has been identified at time of analysis.
RemediationAI
Upgrade Solid Edge SE2025 to V225.0 Update 15 or later, and Solid Edge SE2026 to V226.0 Update 7 or later, as directed by Siemens PSIRT advisory SSA-621657 (https://cert-portal.siemens.com/productcert/html/ssa-621657.html). Where immediate patching is not operationally feasible, enforce file-type filtering and sandboxed preview at email gateways to block untrusted PSM files before they reach end-user workstations - note this may disrupt legitimate external collaboration workflows. Disabling automatic file preview in file managers and restricting which users can open externally sourced CAD files via application allow-listing provides an additional compensating control, though it introduces workflow friction for engineers. User awareness training on the risk of unsolicited or unexpected CAD file attachments reduces the social-engineering delivery surface without operational side effects.
Affected VersionsENISA
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
Siemens Solid Edge is a parametric 3D CAD suite used primarily in mechanical engineering and manufacturing workflows. PSM files are Solid Edge part model files central to the application's daily use. The vulnerability is classified as CWE-787 (Out-of-bounds Write), a memory corruption root cause where the parser writes beyond the bounds of an allocated buffer while processing PSM file content - typically caused by insufficient validation of attacker-controlled length or offset fields within the file format. This class of flaw in file parsers can overwrite adjacent memory structures, enabling control-flow hijacking and arbitrary code execution. Confirmed affected CPE identifiers are cpe:2.3:a:siemens:solid_edge_se2025:*:*:*:*:*:*:*:* and cpe:2.3:a:siemens:solid_edge_se2026:*:*:*:*:*:*:*:*.
Know when Solid Edge Se2025 gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Victim must locally open a crafted file (AV:L, UI:R); high complexity reflects exploit reliability constraints; scope is unchanged and damage is confined to the Solid Edge process (S:U).
Primary rating from Vendor (siemens).
CVSS VectorVendor: siemens
Lifecycle Timeline
4DescriptionCVE.org
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.
Executive ViewAI
Organizations running Siemens Solid Edge SE2025 or SE2026 must immediately patch a critical code execution vulnerability in design file handling to prevent intellectual property theft, system compromise, or production disruption. Because design files are commonly shared both internally and across supply chains, exposure is immediate even though public exploits have not yet surfaced.
Apply vendor patch: Siemens Solid Edge SE2025 V225.0 Update 15 or SE2026 V226.0 Update 7.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
Memory corruption occurs when a program writes data beyond the boundaries of allocated memory regions or accesses memory in unintended ways, violating the integrity of the process's address space.
More in Solid Edge Se2025
View allLocal privilege escalation in Siemens' IAM Client SDK, a shared authentication component bundled across a wide range of
Out-of-bounds read code execution in Siemens Solid Edge SE2025 and SE2026 allows an attacker to execute arbitrary code i
Out-of-bounds read in Siemens Solid Edge's PAR file parser enables code execution within the running process when a vict
Use-after-free in Siemens Solid Edge SE2025 and SE2026 enables arbitrary code execution in the context of the current pr
Use-after-free memory corruption in Siemens Solid Edge SE2025 and SE2026 allows code execution in the context of the cur
Out-of-bounds write in Siemens Solid Edge SE2025 and SE2026 allows code execution within the application process when a
Out-of-bounds read in Siemens Solid Edge SE2025 and SE2026 enables code execution within the application process when a
Improper TLS certificate validation in Siemens Software Center, Simcenter 3D, Simcenter Femap, Simcenter STAR-CCM+, Soli
Out-of-bounds read in Siemens Solid Edge SE2024 before V224.0 Update 14 and SE2025 before V225.0 Update 6 can crash the
Out-of-bounds read in Siemens Solid Edge SE2024 (before V224.0 Update 14) and SE2025 (before V225.0 Update 6) can crash
Out-of-bounds write in Siemens Solid Edge SE2024 and SE2025 PRT-file parsing lets a crafted part file crash the applicat
Out-of-bounds write in Siemens Solid Edge's .PRT part-file parser allows an attacker who convinces a user to open a spec
EUVD-2026-56116
GHSA-qv4h-hhmg-pr37
NVD
CVE.org
EPSS
Vulnrichment
VulDB
Exploit-DB