Skip to main content

Solid Edge Se2026

11 CVEs product

Monthly

CVE-2026-50064 Aug 11, 12:20 HIGH CISA Act Now

Out-of-bounds write in Siemens Solid Edge SE2025 and SE2026 enables code execution within the application's process when a user opens a specially crafted PSM part model file. Affected versions are SE2025 prior to V225.0 Update 15 and SE2026 prior to V226.0 Update 7, confirmed by Siemens PSIRT via advisory SSA-621657. No public exploit has been identified at time of analysis, and the vulnerability does not appear in the CISA KEV catalog.

Buffer Overflow Memory Corruption Siemens Solid Edge Se2025 Solid Edge Se2026
NVD
CVSS 4.0
7.3
EPSS
0.1%
CVE-2026-50063 Aug 11, 12:20 HIGH CISA Act Now

Out-of-bounds read code execution in Siemens Solid Edge SE2025 and SE2026 allows an attacker to execute arbitrary code in the context of the current user process by convincing a target to open a specially crafted PAR (part file) document. The flaw resides in the application's PAR file parser, where insufficient bounds checking on read operations enables memory corruption leading to code execution. No public exploit code and no CISA KEV listing are present at time of analysis; patches are available for both affected release trains.

Buffer Overflow Information Disclosure Siemens Solid Edge Se2025 Solid Edge Se2026
NVD
CVSS 4.0
7.3
EPSS
0.1%
CVE-2026-50062 Aug 11, 12:20 HIGH CISA Act Now

Out-of-bounds read in Siemens Solid Edge's PAR file parser enables code execution within the running process when a victim opens a specially crafted part file. Both active product branches are affected: SE2025 prior to V225.0 Update 15 and SE2026 prior to V226.0 Update 7. No public exploit code or CISA KEV listing exists at time of analysis, but the vendor-confirmed code-execution primitive elevates this beyond a typical information-disclosure finding tagged under CWE-125.

Buffer Overflow Information Disclosure Siemens Solid Edge Se2025 Solid Edge Se2026
NVD
CVSS 4.0
7.3
EPSS
0.1%
CVE-2026-50061 Aug 11, 12:20 HIGH CISA Act Now

Use-after-free in Siemens Solid Edge SE2025 and SE2026 enables arbitrary code execution in the context of the current process when a user opens a specially crafted DFT file. Both affected annual release branches are vulnerable until patched - SE2025 prior to V225.0 Update 15 and SE2026 prior to V226.0 Update 7 - as confirmed by Siemens Security Advisory SSA-621657. No public exploit or active exploitation has been identified at time of analysis; the CVSS 4.0 AC:H rating indicates non-trivial exploit development is required.

Information Disclosure Use After Free Memory Corruption Siemens Solid Edge Se2025 +1
NVD
CVSS 4.0
7.3
EPSS
0.1%
CVE-2026-50060 Aug 11, 12:20 HIGH CISA Act Now

Use-after-free memory corruption in Siemens Solid Edge SE2025 and SE2026 allows code execution in the context of the current user process when a specially crafted DFT (draft) file is parsed. Affected are all SE2025 releases prior to V225.0 Update 15 and all SE2026 releases prior to V226.0 Update 7, as confirmed by Siemens advisory SSA-621657. No public exploit code or active exploitation has been identified at time of analysis, and the local attack vector combined with required user interaction meaningfully constrains real-world exposure.

Information Disclosure Use After Free Memory Corruption Siemens Solid Edge Se2025 +1
NVD
CVSS 4.0
7.3
EPSS
0.1%
CVE-2026-50059 Aug 11, 12:20 HIGH CISA Act Now

Out-of-bounds write in Siemens Solid Edge SE2025 and SE2026 allows code execution within the application process when a user opens a specially crafted DFT file. The vulnerability resides in the DFT file parser and can deliver full confidentiality, integrity, and availability impact on the vulnerable system if a victim is induced to open a malicious file. No public exploit identified at time of analysis, and the product is not listed in CISA KEV; however, Siemens has released patched versions and published advisory SSA-621657.

Buffer Overflow Memory Corruption Siemens Solid Edge Se2025 Solid Edge Se2026
NVD
CVSS 4.0
7.3
EPSS
0.1%
CVE-2026-50058 Aug 11, 12:20 HIGH CISA Act Now

Out-of-bounds read in Siemens Solid Edge SE2025 and SE2026 enables code execution within the application process when a victim opens a specially crafted DFT (Draft) drawing file. Siemens confirmed and patched the vulnerability via Product CERT advisory SSA-621657, with fixes delivered in SE2025 V225.0 Update 15 and SE2026 V226.0 Update 7. No public exploit code or active exploitation has been identified at time of analysis, but the file-parsing attack vector is consistent with targeted document-delivery threats directed at engineering and manufacturing organizations.

Buffer Overflow Information Disclosure Siemens Solid Edge Se2025 Solid Edge Se2026
NVD
CVSS 4.0
7.3
EPSS
0.1%
CVE-2026-44412 May 12, 08:21 HIGH CISA This Week

Stack-based buffer overflow in Siemens Solid Edge SE2026 allows arbitrary code execution when users open malicious PAR files. Attackers must deliver a weaponized PAR file and convince the user to open it, after which code executes with user's privileges. All versions prior to V226.0 Update 5 are vulnerable. No active exploitation confirmed (not in CISA KEV), but the attack relies on user interaction with a common CAD file format, making social engineering feasible in engineering/manufacturing environments.

Buffer Overflow Stack Overflow Siemens Solid Edge Se2026
NVD VulDB
CVSS 4.0
7.3
EPSS
0.0%
CVE-2026-44411 May 12, 08:21 HIGH CISA Act Now

Uninitialized pointer access in Siemens Solid Edge SE2026 enables arbitrary code execution when processing malicious PAR files. Attackers must deliver a crafted PAR file and convince users to open it (CVSS:4.0 AV:L/UI:P), achieving full compromise of the victim's workstation with high confidentiality, integrity, and availability impact. No active exploitation confirmed at time of analysis, though the local attack vector and user interaction requirement limit automated mass exploitation. EPSS data not available for risk calibration.

Information Disclosure Memory Corruption Siemens Solid Edge Se2026
NVD
CVSS 4.0
7.3
EPSS
0.0%
CVE-2025-40945 Jul 14, 09:19 HIGH CISA This Week

Local privilege escalation in Siemens' IAM Client SDK, a shared authentication component bundled across a wide range of Siemens engineering and PLM products (Solid Edge, Teamcenter Visualization, Simcenter, Tecnomatix, COMOS, Designcenter NX), allows an authenticated local user to load attacker-controlled code through an untrusted search path (CWE-426) and gain elevated privileges. The flaw carries a CVSS 4.0 base score of 8.5 and requires only low local privileges with no user interaction. There is no public exploit identified at time of analysis and it is not listed in CISA KEV.

Privilege Escalation Siemens Simcenter Nastran Simcenter 3D Simcenter Star Ccm +13
NVD
CVSS 4.0
8.5
EPSS
0.1%
CVE-2025-40745 Apr 14, 08:40 MEDIUM CISA This Month

Improper TLS certificate validation in Siemens Software Center, Simcenter 3D, Simcenter Femap, Simcenter STAR-CCM+, Solid Edge SE2025/SE2026, and Tecnomatix Plant Simulation allows unauthenticated remote attackers to perform man-in-the-middle attacks against the Analytics Service endpoint. An attacker positioned on the network path can intercept and decrypt communications, potentially disclosing sensitive information. CVSS 3.7 reflects low-severity impact; no public exploit or active exploitation confirmed, but the low attack complexity and network vector indicate practical exploitability in targeted enterprise environments.

Information Disclosure Siemens Simcenter Femap Tecnomatix Plant Simulation Siemens Software Center +4
NVD VulDB
CVSS 4.0
6.3
EPSS
0.0%
EPSS 0% CVSS 7.3
HIGH Act Now

Out-of-bounds write in Siemens Solid Edge SE2025 and SE2026 enables code execution within the application's process when a user opens a specially crafted PSM part model file. Affected versions are SE2025 prior to V225.0 Update 15 and SE2026 prior to V226.0 Update 7, confirmed by Siemens PSIRT via advisory SSA-621657. No public exploit has been identified at time of analysis, and the vulnerability does not appear in the CISA KEV catalog.

Buffer Overflow Memory Corruption Siemens +2
NVD
EPSS 0% CVSS 7.3
HIGH Act Now

Out-of-bounds read code execution in Siemens Solid Edge SE2025 and SE2026 allows an attacker to execute arbitrary code in the context of the current user process by convincing a target to open a specially crafted PAR (part file) document. The flaw resides in the application's PAR file parser, where insufficient bounds checking on read operations enables memory corruption leading to code execution. No public exploit code and no CISA KEV listing are present at time of analysis; patches are available for both affected release trains.

Buffer Overflow Information Disclosure Siemens +2
NVD
EPSS 0% CVSS 7.3
HIGH Act Now

Out-of-bounds read in Siemens Solid Edge's PAR file parser enables code execution within the running process when a victim opens a specially crafted part file. Both active product branches are affected: SE2025 prior to V225.0 Update 15 and SE2026 prior to V226.0 Update 7. No public exploit code or CISA KEV listing exists at time of analysis, but the vendor-confirmed code-execution primitive elevates this beyond a typical information-disclosure finding tagged under CWE-125.

Buffer Overflow Information Disclosure Siemens +2
NVD
EPSS 0% CVSS 7.3
HIGH Act Now

Use-after-free in Siemens Solid Edge SE2025 and SE2026 enables arbitrary code execution in the context of the current process when a user opens a specially crafted DFT file. Both affected annual release branches are vulnerable until patched - SE2025 prior to V225.0 Update 15 and SE2026 prior to V226.0 Update 7 - as confirmed by Siemens Security Advisory SSA-621657. No public exploit or active exploitation has been identified at time of analysis; the CVSS 4.0 AC:H rating indicates non-trivial exploit development is required.

Information Disclosure Use After Free Memory Corruption +3
NVD
EPSS 0% CVSS 7.3
HIGH Act Now

Use-after-free memory corruption in Siemens Solid Edge SE2025 and SE2026 allows code execution in the context of the current user process when a specially crafted DFT (draft) file is parsed. Affected are all SE2025 releases prior to V225.0 Update 15 and all SE2026 releases prior to V226.0 Update 7, as confirmed by Siemens advisory SSA-621657. No public exploit code or active exploitation has been identified at time of analysis, and the local attack vector combined with required user interaction meaningfully constrains real-world exposure.

Information Disclosure Use After Free Memory Corruption +3
NVD
EPSS 0% CVSS 7.3
HIGH Act Now

Out-of-bounds write in Siemens Solid Edge SE2025 and SE2026 allows code execution within the application process when a user opens a specially crafted DFT file. The vulnerability resides in the DFT file parser and can deliver full confidentiality, integrity, and availability impact on the vulnerable system if a victim is induced to open a malicious file. No public exploit identified at time of analysis, and the product is not listed in CISA KEV; however, Siemens has released patched versions and published advisory SSA-621657.

Buffer Overflow Memory Corruption Siemens +2
NVD
EPSS 0% CVSS 7.3
HIGH Act Now

Out-of-bounds read in Siemens Solid Edge SE2025 and SE2026 enables code execution within the application process when a victim opens a specially crafted DFT (Draft) drawing file. Siemens confirmed and patched the vulnerability via Product CERT advisory SSA-621657, with fixes delivered in SE2025 V225.0 Update 15 and SE2026 V226.0 Update 7. No public exploit code or active exploitation has been identified at time of analysis, but the file-parsing attack vector is consistent with targeted document-delivery threats directed at engineering and manufacturing organizations.

Buffer Overflow Information Disclosure Siemens +2
NVD
EPSS 0% CVSS 7.3
HIGH This Week

Stack-based buffer overflow in Siemens Solid Edge SE2026 allows arbitrary code execution when users open malicious PAR files. Attackers must deliver a weaponized PAR file and convince the user to open it, after which code executes with user's privileges. All versions prior to V226.0 Update 5 are vulnerable. No active exploitation confirmed (not in CISA KEV), but the attack relies on user interaction with a common CAD file format, making social engineering feasible in engineering/manufacturing environments.

Buffer Overflow Stack Overflow Siemens +1
NVD VulDB
EPSS 0% CVSS 7.3
HIGH Act Now

Uninitialized pointer access in Siemens Solid Edge SE2026 enables arbitrary code execution when processing malicious PAR files. Attackers must deliver a crafted PAR file and convince users to open it (CVSS:4.0 AV:L/UI:P), achieving full compromise of the victim's workstation with high confidentiality, integrity, and availability impact. No active exploitation confirmed at time of analysis, though the local attack vector and user interaction requirement limit automated mass exploitation. EPSS data not available for risk calibration.

Information Disclosure Memory Corruption Siemens +1
NVD
EPSS 0% CVSS 8.5
HIGH This Week

Local privilege escalation in Siemens' IAM Client SDK, a shared authentication component bundled across a wide range of Siemens engineering and PLM products (Solid Edge, Teamcenter Visualization, Simcenter, Tecnomatix, COMOS, Designcenter NX), allows an authenticated local user to load attacker-controlled code through an untrusted search path (CWE-426) and gain elevated privileges. The flaw carries a CVSS 4.0 base score of 8.5 and requires only low local privileges with no user interaction. There is no public exploit identified at time of analysis and it is not listed in CISA KEV.

Privilege Escalation Siemens Simcenter Nastran +15
NVD
EPSS 0% CVSS 6.3
MEDIUM This Month

Improper TLS certificate validation in Siemens Software Center, Simcenter 3D, Simcenter Femap, Simcenter STAR-CCM+, Solid Edge SE2025/SE2026, and Tecnomatix Plant Simulation allows unauthenticated remote attackers to perform man-in-the-middle attacks against the Analytics Service endpoint. An attacker positioned on the network path can intercept and decrypt communications, potentially disclosing sensitive information. CVSS 3.7 reflects low-severity impact; no public exploit or active exploitation confirmed, but the low attack complexity and network vector indicate practical exploitability in targeted enterprise environments.

Information Disclosure Siemens Simcenter Femap +6
NVD VulDB

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy