Skip to main content

Severity by source

Vendor (siemens) PRIMARY
8.5 MEDIUM
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
6.7 MEDIUM

Local-only attack requiring high-privilege write access to the IAM SDK search path; full C/I/A impact justified as attacker library executes in the application's security context.

3.1 AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
4.0 AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (siemens).

CVSS VectorVendor: siemens

CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

5
Analysis Updated
Jul 14, 2026 - 10:31 vuln.today
v2 (cvss_changed)
Re-analysis Queued
Jul 14, 2026 - 10:22 vuln.today
cvss_changed
Severity Changed
Jul 14, 2026 - 10:22 NVD
MEDIUM HIGH
CVSS changed
Jul 14, 2026 - 10:22 NVD
6.7 (MEDIUM) 8.5 (HIGH)
Analysis Generated
Jul 14, 2026 - 10:16 vuln.today

DescriptionCVE.org

A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (All versions < V2512.7000), Simcenter 3D (All versions < V2512.7000), Simcenter Femap V2506 (All versions < V2506.0003), Simcenter Femap V2512 (All versions < V2512.0002), Simcenter Nastran (All versions < V2606), Simcenter STAR-CCM+ (All versions < V2606), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Teamcenter Visualization V2412 (All versions < V2412.0012), Teamcenter Visualization V2506 (All versions < V2506.0009), Teamcenter Visualization V2512 (All versions < V2512.2605), Tecnomatix Plant Simulation V2404 (All versions < V2404.0022), Tecnomatix Plant Simulation V2504 (All versions < V2504.0010), Tecnomatix Process Simulate (All versions < V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access.

AnalysisAI

Local privilege escalation in Siemens' IAM Client SDK, a shared authentication component bundled across a wide range of Siemens engineering and PLM products (Solid Edge, Teamcenter Visualization, Simcenter, Tecnomatix, COMOS, Designcenter NX), allows an authenticated local user to load attacker-controlled code through an untrusted search path (CWE-426) and gain elevated privileges. The flaw carries a CVSS 4.0 base score of 8.5 and requires only low local privileges with no user interaction. There is no public exploit identified at time of analysis and it is not listed in CISA KEV.

Share

CVE-2025-40945 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy