Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A08:2025 - Software or Data Integrity Failures
ASVS 5.0
V13 - Configuration Search path verification
Act Now Prioritize within 24-48h. Why: Active threat signals + CRITICAL/HIGH severity.
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv2 – Jul 14, 2026

Local privilege escalation in Siemens' IAM Client SDK, a shared authentication component bundled across a wide range of Siemens engineering and PLM products (Solid Edge, Teamcenter Visualization, Simcenter, Tecnomatix, COMOS, Designcenter NX), allows an authenticated local user to load attacker-controlled code through an untrusted search path (CWE-426) and gain elevated privileges. The flaw carries a CVSS 4.0 base score of 8.5 and requires only low local privileges with no user interaction. There is no public exploit identified at time of analysis and it is not listed in CISA KEV.

Earlier versions of this analysis (1)
v1 Jul 14, 2026 - 10:16 CVSS 6.7

Privilege escalation via untrusted search path (CWE-426) in the Siemens IAM Client SDK component affects 16 distinct Siemens industrial engineering and simulation product lines, including COMOS, Solid Edge, Simcenter, Teamcenter Visualization, and Tecnomatix families. An authenticated local user who already holds high system privileges can plant a malicious library in a directory searched by the IAM Client SDK, causing the SDK to load and execute attacker-controlled code during application initialization or authentication events. No public exploit code exists and this CVE is not listed in CISA KEV at time of analysis; however, the broad cross-product footprint through a shared component amplifies aggregate organizational exposure in Siemens-heavy industrial environments.

Affected VersionsENISA

COMOS V10.6 0 <V10.6.1
Designcenter NX 0 <V2512.7000
Simcenter Femap V2506 0 <V2506.0003
Simcenter 3D 0 <V2512.7000
Solid Edge SE2026 0 <V226.0 Update 04
Simcenter STAR-CCM+ 0 <V2606
Solid Edge SE2025 0 <V225.0 Update 13
COMOS V10.4.5 0 <V10.4.5.0.2
Simcenter Femap V2512 0 <V2512.0002
Teamcenter Visualization V2412 0 <V2412.0012
Tecnomatix Process Simulate 0 <V2606
Simcenter Nastran 0 <V2606
Tecnomatix Plant Simulation V2404 0 <V2404.0022
Teamcenter Visualization V2506 0 <V2506.0009
Tecnomatix Plant Simulation V2504 0 <V2504.0010
Teamcenter Visualization V2512 0 <V2512.2605

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Know when Designcenter Nx gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (siemens) PRIMARY 8.5 MEDIUM
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
vuln.today AI 6.7 MEDIUM

Local-only attack requiring high-privilege write access to the IAM SDK search path; full C/I/A impact justified as attacker library executes in the application's security context.

3.1 AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
4.0 AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (siemens).

CVSS VectorVendor: siemens

Attack Vector
Local
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

3
Analysis Updated
Jul 14, 2026 - 10:31 vuln.today
v2 - CVSS changed
Severity Changed
Jul 14, 2026 - 10:22 NVD
MEDIUM HIGH
CVSS changed
Jul 14, 2026 - 10:22 NVD
6.7 (MEDIUM) 8.5 (HIGH)

DescriptionCVE.org

A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (All versions < V2512.7000), Simcenter 3D (All versions < V2512.7000), Simcenter Femap V2506 (All versions < V2506.0003), Simcenter Femap V2512 (All versions < V2512.0002), Simcenter Nastran (All versions < V2606), Simcenter STAR-CCM+ (All versions < V2606), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Teamcenter Visualization V2412 (All versions < V2412.0012), Teamcenter Visualization V2506 (All versions < V2506.0009), Teamcenter Visualization V2512 (All versions < V2512.2605), Tecnomatix Plant Simulation V2404 (All versions < V2404.0022), Tecnomatix Plant Simulation V2504 (All versions < V2504.0010), Tecnomatix Process Simulate (All versions < V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access.

Executive ViewAI

Why It Matters

Siemens IAM Client SDK (embedded in Solid Edge, Teamcenter Visualization, Simcenter, Tecnomatix, COMOS, and Designcenter NX) contains a local privilege escalation flaw allowing authenticated users to execute code with elevated access. No patch is currently available, placing engineering and PLM operations at immediate risk of insider threat exploitation or lateral movement following workstation compromise.

Recommended Action

Within 24 hours, inventory all Siemens product deployments using IAM Client SDK and restrict local administrative access to engineering workstations; review and disable untrusted search paths through Windows security policies (AppInit_DLLs, user-writable directory removal from PATH). Within 7 days, implement privilege access management (PAM) controls for engineering workstations requiring elevated tasks to route through hardened jump hosts; enable monitoring for privilege escalation and DLL injection anomalies; contact Siemens support for patch availability timeline. Within 30 days, develop and stage a patch deployment plan for immediate rollout when Siemens releases a fix; evaluate network segmentation to isolate affected systems and reduce lateral movement risk from compromised endpoints.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations: enforce least-privilege execution on affected applications; disable AppInit_DLLs and user-writable PATH entries via Group Policy; implement file integrity monitoring on system and application directories; restrict local administrator rights and enforce privileged access management for administrative tasks; apply network segmentation to limit lateral movement if an engineering workstation is compromised; monitor for anomalous privilege escalation and DLL loading from untrusted paths.

Threat Intelligence Overview

EPSS Score
0.1%
Top 96% exploitable
Threat Intel
1
1 sources
Data Quality
7 sources
Confidence: High
EUVD NVD CVE.org EPSS Vulnrichment CISA VulDB

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.1%
Patch available No
Active threat Yes
Deciding rule
Active threat signals + CRITICAL/HIGH severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Small
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

52
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +42
PoC: 0
Weaponized: 0
Threat intel: +10
Gov advisory: 0

Attack Technique

Privilege escalation occurs when an attacker leverages flaws in access control mechanisms to gain permissions beyond what they were originally granted.

Threat IntelligenceMISP

CISA Advisories
Sources: CISA Vulnrichment, CISA (public domain)

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy